2
61287833F1-13C
3
WARNING!
Ensure that the 611 GPON ONT does not come in contact with
water or other liquids.
Wall Mounting
when installing the 611 GPON ONT on a wall.
1. Decide on a location for the 611 GPON ONT. Mount below eye-level
so the LEDs are visible.
g
NOTE
Supplied hardware is intended for drywall mounting only. For
mounting on surfaces other than drywall, obtain the appropriate
mounting hardware and follow the provided instructions.
Figure 3. Wall Mount Installation
2. Use the keyholes on the rear of the 611 GPON ONT as a template
and mark the wall accordingly. The keyhole spacing for a vertical
mount is 1.97 inches (5 cm).
3. Drill holes using a 1/4” drill bit into the marks on the wall.
4. Use a hammer to lightly tap the included wall anchors into the drilled
holes until anchor is flush with the wall.
5. Install two included screws into the anchor heads. Leave
approximately 1/4 inch (6 mm) protruding from the mounting
surface.
6. Slide the 611 GPON ONT over the screws and exert a small amount
of downward pressure to ensure that the top of the slots are resting
on the shafts of the screws.
Step 2: Connect Ethernet
on page 1 and insert a Category 5E (or better) RJ-45
cable into the port labeled
GE
until there is an audible “click”.
Step 3: Connect Fiber
f
CAUTION!
To prevent breaking the fiber, do not exceed the fiber bend radius of 3.5 in.
(8.9 cm).
Wall Anchor (2x)
Mounting Screw (2x)
Power
Power is provided by a 12 V DC Power Adapter that is included with the
611 GPON ONT. The power adapter operates from a power source of 100
to 240 V AC, 50 - 60 Hz. For the United States and Canada applications,
an NRTL Listed Limited Power Source (LPS) is needed. For deployment
in international
applications, an LPS specifically approved for that country, as indicated by
a CE Mark, is needed.
I
NSTALLATION
After unpacking the unit, inspect it for damage. If damage is noted, file a
claim with the carrier and then contact ADTRAN. For more information,
refer to the warranty.
Installation Guidelines
The following are guidelines for basic installation of the 611 GPON ONT.
f
WARNING!
Read all warnings and cautions before installing or servicing the
611 GPON ONT.
Installation Overview
To install the 611 GPON ONT, you will need to complete the following
steps:
■
“Step 1: Install the 611 GPON ONT”
■
■
■
Required Tools:
Be sure to route and secure the fiber and cables in a manner that will
prevent damage. Standard technician tools and those listed below are
required for installing the 611 GPON ONT.
■
Optical power meter with wavelength filtering
■
Fiberscope or videoscope
■
#2 Phillips-head screw driver
■
Drill
■
Hammer
For fiber optics connections, the following is required:
■
ODC Fiber Cleaning Tool
Step 1: Install the 611 GPON ONT
There are two options to install the 611 GPON ONT: Desk Top and Wall
Mount. Options are described below.
g
NOTE
Included with the 611 GPON ONT is a 5-foot (1.5 m) power cord.
All installation locations should be within 5 feet (1.5 m) of a wall
outlet.
Desk Top Installation
The 611 GPON ONT can be located on a desktop.
f
CAUTION!
Ensure that the 611 GPON ONT is not located in direct sunlight or next to
any thermal obstructions.