Unit Installation
NetVanta 6355 PoE Hardware Installation Guide
36
Copyright © 2011 ADTRAN, Inc.
61200740E1-34D
Tools Required
The customer-provided tools required for the hardware installation of the NetVanta are:
•
Ethernet cables
•
Network cables (module dependent)
•
DSX-1 cable (T1/FT1 + DSX-1 module only)
•
Phillips-head screwdriver (rack-mounted applications only)
Mounting Options
The unit may be installed in rackmount, wallmount, or tabletop configurations. The following sections provide
step-by-step instructions for rack mounting and wall mounting.
Rack Mounting the NetVanta
The NetVanta is a 1U-high, rack-mountable unit that can be installed into a 19-inch equipment rack. The
following steps guide you in mounting the NetVanta into a rack.
To access the CLI of the NetVanta, you will also need a PC with VT-100 terminal emulation
software and a console port cable. Instructions on how to access the CLI are available in
the quick start guide shipped with your unit or online on the
ADTRAN Support Community
.
If you have purchased the VPN Accelerator Card for your NetVanta 6355 PoE, install it
first (refer to
Installing the NetVanta VPN Accelerator Card (included in P/N 4200368L1)
on page 41
).
•
If installed in a closed or multi-unit rack assembly, the operating ambient temperature
of the rack environment may be greater than room ambient temperature. Therefore,
consideration should be given to installing the equipment in an environment compatible
with the maximum ambient temperature specified by the manufacturer.
•
Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
•
Be careful not to compromise the stability of the equipment mounting rack when
installing this product.
•
Consideration should be given to the connection of the equipment to the supply circuit
and the effect that overloading the circuit might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment nameplate ratings should be
used when addressing this concern.
•
Reliable grounding of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the
branch circuit (e.g., use of power strips).