Switch Management
ADTRAN 1748F Switch
38
Copyright © 2016 ADTRAN, Inc.
61700558F1-34B
To connect to the management port, use Category 5 or better unshielded twisted-pair (UTP) cable with RJ-45
connectors at both ends. Make sure the twisted-pair cable does not exceed 100 meters (328 ft) in length. This
port supports automatic MDI/MDI-X pinout configuration, so you can use standard straight-through cables to
connect to any other network device.
Follow these steps to connect to the Management port:
Connecting to the Console Port
The RJ-45
Console
port on the switch’s front panel is used to connect to the switch for out-of-band console
configuration. The console device can be a PC or workstation running a VT-100 terminal emulator, or a VT-100
terminal. An RJ-45-to- DB-9 cable is supplied with the switch for connecting to a PC’s RS-232 serial DB-9 DTE
(COM) port.
Figure 20. Console Port
Instructions for Connecting to the Management Port
Step
Action
1
Attach one end of a twisted-pair cable to an RJ-45 connector on a management network device
(PC or another switch).
2
Attach the other end of the twisted-pair cable to the Management port on the switch.
3
As the connection is made, the
Mgmt
port LEDs (on the switch) will turn on to indicate that the
connection is valid.
To connect to notebooks or other PCs that do not have a DB-9 COM port, use a USB to
male DB-9 adapter cable (not included with the switch).
Console Port
Содержание NetVanta 1748F Series
Страница 1: ...ADTRAN 1748F Switch Hardware Installation Guide 1700558F1 ADTRAN 1748F 61700558F1 34B December 2016...
Страница 8: ...Table of Contents ADTRAN 1748F Switch 8 Copyright 2016 ADTRAN Inc 61700558F1 34B...
Страница 10: ...List of Figures ADTRAN 1748F Switch 10 Copyright 2016 ADTRAN Inc 61700558F1 34B...
Страница 12: ...List of Tables ADTRAN 1748F Switch 12 Copyright 2016 ADTRAN Inc 61700558F1 34B...
Страница 42: ...Troubleshooting ADTRAN 1748F Switch 42 Copyright 2016 ADTRAN Inc 61700558F1 34B...