Table 1.  Fan Tray Specifications

To replace the fan tray, follow these steps:

Supplying Power to the Unit

This chapter focuses on the switch power supplies, how to install them, and how to power-on the switch. 
Connecting the switch to ground is also covered.

This section includes these sections:

Power Supply Modules on page 22

Grounding the Chassis on page 23

Connecting to AC Power on page 24

Power Supply Modules

The switch supports hot-swappable power supply units (PSUs). You can install up to two PSUs with matching 
airflow direction in the switch. The PSUs operate in a load-sharing mode and provide 1+1 redundancy.

Item

Description

Power Consumption

12 VDC @ 2.8 A, 37 Watts maximum

Airflow

76.4 CFM minimum
90.4 CFM maximum

Dimensions

207mm W x 94.25 mm D x 40.4 mm H 
(8.15 inch W x 3.71 inch D x 1.59 inch H)

Replacing the Fan Tray

Step

Action

1

Loosen the two retaining screws on the front panel of the fan tray (see 

Figure 8

).

2

Pull firmly on the screws until the fan tray is free.

3

Slide the fan tray out of the switch.

4

Insert the replacement fan tray into the slot and slide it slowly into the chassis.

5

Push firmly until the fan tray clicks into place. The fans should immediately start to operate.

6

Tighten the retaining screws to secure the fan tray in the chassis.

1+1 redundancy is a system where a switch power supply is backed up by another switch 
power supply in a load-sharing mode. If one power supply fails, the other power supply 
takes over the full load of the switch.

The switch includes plug-in power supply and fan tray modules that are installed into its 
chassis. All installed modules must have a matching airflow direction. That is, all modules 
must have a front-to-back (F2B) airflow direction, or all modules must have a 
back-to-front (B2F) airflow direction. The airflow direction of PSUs and fan trays is 
indicated by labels on the modules.

Содержание NetVanta 1748F Series

Страница 1: ...ADTRAN 1748F Switch Hardware Installation Guide 1700558F1 ADTRAN 1748F 61700558F1 34B December 2016...

Страница 2: ...ion Software Licensing Agreement Each ADTRAN product contains a single license for ADTRAN supplied software Pursuant to the Licensing Agreement you may a use the software on the purchased ADTRAN devic...

Страница 3: ...2016 ADTRAN Inc 3 Conventions Notes provide additional useful information Cautions signify information that could prevent service interruption or damage to the equipment Warnings provide information...

Страница 4: ...ug the product from the electrical outlet and replace the part or contact your qualified service personnel 1 The power cable extension cable or plug is damaged 2 An object has fallen into the product...

Страница 5: ...void your authority to operate the equipment You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or better for 10 Mbps connections Category 5 or better for 100 Mbps connections Ca...

Страница 6: ...IMPROPER USE OF ADTRAN EQUIPMENT OR SOFTWARE THEREFORE ADTRAN IS NOT LIABLE FOR ANY LOSSES OR DAMAGES RESULTING FROM SUCH FRAUD ATTACK OR IMPROPER USE INCLUDING BUT NOT LIMITED TO HUMAN AND DATA PRIV...

Страница 7: ...Understanding the Port Status LEDs 27 Installing an SFP SFP QSFP Transceiver 27 Connecting to Twisted Pair Copper Ports 28 Connecting to SFP SFP Fiber Optic Ports 31 Connecting to QSFP Fiber Optic Por...

Страница 8: ...Table of Contents ADTRAN 1748F Switch 8 Copyright 2016 ADTRAN Inc 61700558F1 34B...

Страница 9: ...Figure 9 AC Power Supply Module 23 Figure 10 Grounding Terminal 24 Figure 11 AC PSU and Power Socket 25 Figure 12 Port Status LEDs 27 Figure 13 Inserting an SFP SFP QSFP Transceiver into a Slot 28 Fi...

Страница 10: ...List of Figures ADTRAN 1748F Switch 10 Copyright 2016 ADTRAN Inc 61700558F1 34B...

Страница 11: ...0BASE T MDI and MDI X Port Pinouts 30 Table 7 Maximum 10 Gigabit Ethernet Fiber Cable Lengths 31 Table 8 Maximum Gigabit Ethernet Fiber Cable Lengths 31 Table 9 Maximum 40 Gigabit Ethernet Fiber Cable...

Страница 12: ...List of Tables ADTRAN 1748F Switch 12 Copyright 2016 ADTRAN Inc 61700558F1 34B...

Страница 13: ...eADTRAN 1748F switch is a high performance top of rack switch designed for campus local area network LAN and data center operating environments The switch provides 48 10G Ethernet Small Form Factor Pl...

Страница 14: ...tion refer to Connecting to the Console Port on page 38 Management Port The RJ 45 port labeled Management provides a dedicated 1000BASE T management interface For more information refer to Connecting...

Страница 15: ...power supplies how to install them and how to power the switch refer to Power Supply Modules on page 22 Product Specifications Ports 48 10 Gbps SFP transceiver slots 4 40 Gbps QSFP transceiver slots...

Страница 16: ...ith a high port density The switch includes redundant hot swappable load sharing AC PSUs a hot swappable fan tray and port to power and power to port airflow direction options Meeting the network scal...

Страница 17: ...ront B2F airflow direction the top of rack switch includes power supply and fan tray modules that reverse the airflow direction through the switch This enables various deployment options for the switc...

Страница 18: ...he ADTRAN 1748F Switch includes the following items ADTRAN 1748F base unit Rack mounting kit containing two brackets and eight screws for attaching the brackets to the switch Grounding wire U S power...

Страница 19: ...he equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer Installation of the equipment in a rack should be such that the amount of air flow required...

Страница 20: ...l installed modules must have a matching airflow direction The following figure shows the airflow through the switch Figure 7 Switch Cooling Rack Mounting the Unit Using the Rack Mounting Brackets Ste...

Страница 21: ...le must be installed in the switch at all times If a fan should fail the whole fan tray module must be replaced as soon as possible You must install the fan tray module in the switch that matches the...

Страница 22: ...inch D x 1 59 inch H Replacing the Fan Tray Step Action 1 Loosen the two retaining screws on the front panel of the fan tray see Figure 8 2 Pull firmly on the screws until the fan tray is free 3 Slide...

Страница 23: ...hassis The switch chassis must be connected to ground to ensure proper operation and to meet electromagnetic interference EMI and safety requirements Item Description AC Input 100 to 240 VAC 50 to 60...

Страница 24: ...hat the external AC power supply can provide 100 to 240 VAC 50 60 Hz 3 A minimum The earth connection must not be removed unless all supply connections have been disconnected Ensure that the rack on w...

Страница 25: ...nnect the field ground lead on the tri pole power plug to a valid earth ground line to prevent electrical hazards This unit operates under SELV Safety Extra Low Voltage conditions according to UL 6095...

Страница 26: ...nd to record where each cable is connected Doing so will enable you to easily locate inter connected devices isolate faults and change your topology without need for unnecessary time consumption To be...

Страница 27: ...are listed below 40 Gbps Ethernet QSFP transceivers 10 Gbps Ethernet SFP transceivers 1000 Mbps Ethernet SFP transceivers LED Color Indication 10G SFP Ports 1 through 48 Off The link is down Green so...

Страница 28: ...a Class 1 Laser Product and are inherently eye safe in normal operation However you should never look directly at a transmit port when it is powered on Instructions for Installing SFP SFP QSFP Transce...

Страница 29: ...or 1000BASE T Protection from radio frequency interference emissions Electrical surge suppression Separation of electrical wires switch related or other and electromagnetic fields from data based netw...

Страница 30: ...r Category 5 Therefore the first step in preparing existing Category 5 cabling for running 1000BASE T is a simple test of the cable installation to be sure that it complies with the IEEE 802 3 2008 st...

Страница 31: ...000BASE SX 62 5 125 micron multimode 160 MHz km 2 220 m 7 722 ft LC 200 MHz km 2 275 m 7 902 ft LC 50 125 micron multimode 400 MHz km 2 500 m 7 1641 ft LC 500 MHz km 2 550 m 7 1805 ft LC 1000BASE LX 9...

Страница 32: ...gs by wiping them gently with a clean tissue or cotton ball moistened with a little ethanol Dirty fiber terminators on fiber cables will impair the quality of the light transmitted through the cable a...

Страница 33: ...ature that is not less than the recommended maximum operational temperature of the product You must also use an approved Laser Class 1 QSFP transceiver Instructions for Connecting to QSFP Fiber Optic...

Страница 34: ...Ethernet solution for short distances ideal for connections within the data center A 10G DAC connection is also known as twinaxial copper or 10GBASE CR DAC copper cables are available in pre terminate...

Страница 35: ...QSFP transceiver connector on one end of a twinaxial copper cable segment into an SFP QSFP slot on the link device see Figure 17 on page 35 2 Plug the other end of the twinaxial cable into an SFP QSFP...

Страница 36: ...o the Management port when access through the data channel is not possible or deemed insecure For a detailed description of the switch s software features refer to the DCSS Administrator s Guide avail...

Страница 37: ...evice Figure 19 Management Port Table 13 RJ 45 Management Port Status LEDs LED Color Indication PSU1 PSU2 Off Unit is not receiving power Green solid Power supply is installed and operating normally A...

Страница 38: ...h for out of band console configuration The console device can be a PC or workstation running a VT 100 terminal emulator or a VT 100 terminal An RJ 45 to DB 9 cable is supplied with the switch for con...

Страница 39: ...Console Port Null Modem PC s 9 Pin DTE Port 6 RXD receive data 3 TDX transmit data 3 TDX transmit data 2 RXD receive data 5 SGND signal ground 5 SGND signal ground Instructions for Connecting to the...

Страница 40: ...Port The USB port on the switch front panel is for transferring configuration files from a USB storage device to the switch s flash memory Figure 22 USB Port Resetting the Switch The reset button on...

Страница 41: ...ower outlet If you still cannot isolate the problem the PSU may be defective Installation Verify that all system components have been properly installed If one or more components appear to be malfunct...

Страница 42: ...Troubleshooting ADTRAN 1748F Switch 42 Copyright 2016 ADTRAN Inc 61700558F1 34B...

Отзывы: