ADTRAN NetVanta 1560-08-65W Скачать руководство пользователя страница 5

617101561PF2-13A

5

Initially Configuring the Switch

The Switch can be configured by two methods:

■ Web based Graphical User Interface (GUI)

■ Command Line Interface (CLI)

Initial Switch Configuration Using a Web Browser

After powering up the switch for the first time, you can perform the initial switch configuration using a web browser. 

To begin with the initial configuration stage, you need to reconfigure your PC’s IP address and subnet mask to make sure the PC can communicate with the switch. After 

changing PC’s IP address (for example, 10.10.10.250), then you can access the web interface of the switch using the switch’s default IP address as shown below.

g

     NOTE

The factory default IP address of the switch is 10.10.10.1. The factory default subnet mask is 255.255.255.0. If the switch is connected to a Dynamic Host Control Protocol 

(DHCP) server, the server assigns the switch an IP address and the default 10.10.10.1 IP address is not configured. The DHCP server also assigns your PC the correct IP 

address to allow a connection on the same subnet as the switch.

Initial Switch Configuration Procedure

To initially configure the switch, complete the following steps.

1. Power up the PC that you will use for the initial configuration. Please make sure the PC has the Ethernet RJ-45 connector to be connected to the switch via standard 

Ethernet LAN cable. If the switch is connected to a DHCP server, skip to Step 3.

2. Reconfigure the PC’s IP address and subnet mask as below, so that it can communicate with the switch. For example, the method to change the PC’s IP address for a 

PC running Windows® 7/8.x/10 is as follows:
a. Type 

network and sharing

 into the Search box in the Start Menu.

b. Select 

Network and Sharing Center

.

c. Select 

Change adapter settings

 on the left of PC screen.

g

     NOTE

Users can also skip Steps 1-2, by pressing 

R

 and typing the ncpa.cpl command to get to Step 4 directly.

Right-click on your local adapter and select 

Properties

.

In the 

Local Area Connection Properties

 menu, highlight 

Internet Protocol Version 4 (TCP/IPv4)

. Then, select the 

Properties

 button.

g

     NOTE

Be sure to record all your PC’s current IP settings to be able to restore them later.

Select the radio button 

Use the following IP address

 and enter in the IP address for the PC (e.g., any IP address not in use, and in between 10.10.10.2 and 

10.10.10.254), subnet mask (e.g., 255.255.255.0). 

Select 

OK

 to change the PC’s IP address.

3. Power up the switch to be initially configured, and wait until it has finished its start-up processes.

4. Connect the PC to any port on the switch using a standard Ethernet cable, and check the port LED on the switch to make sure the link status of the PC is OK.

5. Run your web browser on the PC; enter either the DHCP-assigned or factory default IP address to access the switch’s web interface. If your PC is configured correctly, 

you will see the login page of the switch requesting your username and password. In some browsers, the information needed may be requested in a new window. 

If you do not see the login page, perform the following steps: 

a. Refresh the web page. 
b. Check to see if there is an IP conflict issue. 

c. Clean browser cookies and temporary Internet files. 

d. Check your PC settings again and repeat Step 2.

6. Enter the factory default username in the login page. Select 

Login

 to log into the switch. 

g

     NOTE

The factory default username of the switch is 

admin

. The factory default password is 

password

.

Initial Switch Configuration Using CLI

The CLI can be accessed using any one of the two console ports (USB & RJ45) available in the switch. To establish the connection to the console port, the following are needed:

■ PC with VT100 terminal emulation software

■ Micro USB to USB cable or a DB-9 to RJ45 Serial Cable (the cables are provided along with the unit)

g

     NOTE

There are many terminal emulation applications available on the web. PuTTY, SecureCRT, and HyperTerminal are a few examples.

Complete the following steps:

1. Connect a Micro USB cable to the micro USB CONSOLE port or connect a DB-9 to RJ-45 serial cable to the RJ-45 CONSOLE port.

2. If using a Micro USB cable, connect the other end of the USB cable to a USB port on the PC. If using an RJ-45 serial cable, connect the other end to the serial terminal 

on the PC.

3. If using the Micro USB cable to connect the switch, check if the USB drivers are automatically installed in the PC. If not install manually.

4. Open a VT100 terminal session using the following settings: 115200 baud; 8 data bits; no parity bits; 1 stop bit; and no flow control. Press <Enter> to activate the CLI.
5. Login with the default user name (

admin

) and password (

password

).

Содержание NetVanta 1560-08-65W

Страница 1: ...cal electrical codes for the requirements for power grounding wiring and installation methods f WARNING Read all warnings cautions notes and installation instructions before installing or servicing th...

Страница 2: ...5W switch complete the following steps Mount The Switch The switch can be mounted in a 19 inch rack on a desk or shelf or on a wall Mounting in a 19 inch Rack g NOTE Mounting brackets are not included...

Страница 3: ...ot compromised Allow 1 inch clearance on the top and sides of the unit for sufficient air flow Mounting on a Wall To mount the switch on a wall complete the following steps 1 Using the mounting holes...

Страница 4: ...local AC Powered product The Surge Protection device should provide L N L G and N G protection It is also recommended that the device contains a visual GOOD indicator f WARNING This equipment incorpor...

Страница 5: ...following IP address and enter in the IP address for the PC e g any IP address not in use and in between 10 10 10 2 and 10 10 10 254 subnet mask e g 255 255 255 0 Select OK to change the PC s IP addr...

Страница 6: ...PD Mode LED Is Lit When the LINK ACT SPD Mode LED is lit the link act spd status is indicated by the LED behavior LED Color State Description SYSTEM Off The switch is not receiving power On The switch...

Страница 7: ...n disabled through the switch user interface Task Press for System LED Behavior Port Status LED Behavior Change LED Mode 0 2 seconds Solid Green LED status will change according to the mode selected R...

Страница 8: ...gned to function without degradation during the exposure to all test severities per 3 1of ETSI EN 300 019 1 3 Electrical Power Supply 100 to 240 VAC 50 60 Hz 2A f CAUTION Electrostatic Discharge ESD c...