617101561PF2-13A

Connect AC Power

To connect the AC power cord to the switch, complete the following steps.

1. Connect the AC power cord to the AC power receptacle on the rear panel of the switch. 

2. Connect the other end of the AC power cord to a properly grounded AC power outlet. The AC branch circuit socket-outlet must be installed near the equipment and must 

be easily accessible.

3. Confirm that the power is connected properly. The 

SYSTEM

 LED should be ON (see 

“SYSTEM Status LED”

).

Figure 8. Connecting the AC Power Cord

g

     NOTE

The installation of this product must comply with the national, state and local electrical code requirements, as applicable. The AC branch circuit overcurrent protection must be a 

fuse or circuit breaker rated 125 VAC, 20 Amps maximum or 250 VAC, 16 Amps maximum. A readily accessible disconnect device that is suitably approved and rated must be 

incorporated in the field wiring.

f

     

CAUTION!

It is recommended that an external AC Surge Protection Device be installed at the AC input connection to the local AC-Powered product. The Surge Protection device should 

provide L-N, L-G, and N-G protection. It is also recommended that the device contains a visual 'GOOD' indicator.

f

     

WARNING!

This equipment incorporates double pole/neutral fusing. If the neutral fuse opens and the line fuse does not open, voltage could still be present in the unit.

Install SFP Modules

You can install or remove an SFP module from an SFP port without having to power off the switch. To install an SFP module, complete the following steps.

1. Insert the module into the appropriate SFP port. 

2. Press firmly to ensure that the module seats properly into the connector.

Figure 9. Installing an SFP Module into an SFP Port

g

     NOTE

This product is intended for use with a Class 1 Laser module that complies with FDA 21 CFR 1040.10, 1040.11 and IEC 60825-1. For continued compliance with the above 

standards, only approved Class 1 Laser modules from an ADTRAN approved vendor list (located on the ADTRAN website) should be installed in this product. ADTRAN cannot 

certify system integrity with other laser modules. The CDRH Laser Class emitted by the Fiber Optic Laser Module Component is Class I or 1 when installed in the end-product 

with the fiber-optic cable removed.

Содержание NetVanta 1560-08-65W

Страница 1: ...cal electrical codes for the requirements for power grounding wiring and installation methods f WARNING Read all warnings cautions notes and installation instructions before installing or servicing th...

Страница 2: ...5W switch complete the following steps Mount The Switch The switch can be mounted in a 19 inch rack on a desk or shelf or on a wall Mounting in a 19 inch Rack g NOTE Mounting brackets are not included...

Страница 3: ...ot compromised Allow 1 inch clearance on the top and sides of the unit for sufficient air flow Mounting on a Wall To mount the switch on a wall complete the following steps 1 Using the mounting holes...

Страница 4: ...local AC Powered product The Surge Protection device should provide L N L G and N G protection It is also recommended that the device contains a visual GOOD indicator f WARNING This equipment incorpor...

Страница 5: ...following IP address and enter in the IP address for the PC e g any IP address not in use and in between 10 10 10 2 and 10 10 10 254 subnet mask e g 255 255 255 0 Select OK to change the PC s IP addr...

Страница 6: ...PD Mode LED Is Lit When the LINK ACT SPD Mode LED is lit the link act spd status is indicated by the LED behavior LED Color State Description SYSTEM Off The switch is not receiving power On The switch...

Страница 7: ...n disabled through the switch user interface Task Press for System LED Behavior Port Status LED Behavior Change LED Mode 0 2 seconds Solid Green LED status will change according to the mode selected R...

Страница 8: ...gned to function without degradation during the exposure to all test severities per 3 1of ETSI EN 300 019 1 3 Electrical Power Supply 100 to 240 VAC 50 60 Hz 2A f CAUTION Electrostatic Discharge ESD c...