Power over Ethernet
The NetVanta 1235P provides the ability to detect attached powered devices (PDs) and deliver power to the PD
via existing Ethernet cabling. The NetVanta 1235P is fully compliant with the IEEE 802.3af PoE standard. By
default, the PoE switches discover and provide power to IEEE-compliant PDs.
ADTRAN’s ActivReach Ethernet supports Power over Ethernet (PoE) over a single pair. When used in
conjunction with the NetVanta ActivReach Media Converter (P/N 1702595G12), power can be either
terminated at the Media Converter or supplied to a downstream device.
NetVanta 1235P Shipping Contents
Each NetVanta 1235P unit is shipped in its own cardboard shipping carton. Open each carton carefully, and
avoid deep penetration into the carton with sharp objects.
After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit,
immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the
Support
page on
the ADTRAN website at
http://www.adtran.com/support
).
Domestic shipments of the NetVanta 1235P includes the following items:
•
NetVanta 1235P base unit
•
A detachable power cable with a grounded, three-prong plug
•
Quick start guide
•
Two 19-inch rack mounting brackets with four mounting screws
International shipments of the NetVanta 1235P includes the following items:
•
NetVanta 1235P base unit
•
All necessary power cords
•
Quick start guide
•
Two 19-inch rack mounting brackets with four mounting screws
NetVanta 1235P Front Panel Design
The NetVanta 1235P front panel is shown below.
Table 1 on page 18
describes all of the LEDs, and
Appendix A on page 39
shows the connector pinouts.
Figure 1. NetVanta 1235P Front Panel Layout
Front Panel Features
Status LED
The
STAT
LED is located on the left side of the unit and indicates the unit’s status.
Redundant Power Supply LED
The
RPS
LED is located on the left side of the unit and indicates when the unit is receiving power
from the RPS.
NetVanta 1235P
G1
G2
G3
G4
VCID
PoE
LINK/ACT
EPS
RPS
STAT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
ActivReach
1G
2.5G
Содержание NetVanta 1235P
Страница 10: ...List of Figures NetVanta 1235P Hardware Installation Guide 10 Copyright 2013 ADTRAN Inc 61700595G10 34A...
Страница 12: ...List of Tables NetVanta 1235P Hardware Installation Guide 12 Copyright 2013 ADTRAN Inc 61700595G10 34A...
Страница 38: ...NetVanta 1131 RPS EPS NetVanta 1235P Hardware Installation Guide 38 Copyright 2013 ADTRAN Inc 61700595G10 34A...