background image

 Physical Descriptions

NetVanta 1230 Series Hardware Installation Guide

 18

Copyright © 2014 ADTRAN, Inc.

61702594G1-34D

NetVanta 1238P Front Panel Design

The NetVanta 1238P front panel is shown below. 

Table 1 on page 20

 describes all of the LEDs, and 

Appendix 

A on page 27 

 shows the connector pinouts.

Figure 5.  NetVanta 1238P Front Panel Layout

NetVanta 1238P Front Panel Features

Status LED

The 

STAT 

LED, located on the left side of the unit, indicates the unit’s status.

Link/Activity LED

The 

LNK/ACT

 LED, located on the left side of the unit, indicates that the port LEDs are displaying 

link/activity status.

Power over Ethernet LED

The 

PoE

 LED, located on the left side of the unit, indicates that the port LEDs are displaying PoE 

status.

VCID LED (Future Release)

The 

VCID

 LED, located on the left side of the unit, indicates that the port LEDs are displaying VCID.

LED Mode Switch (Future Release)

The LED mode switch is located on the left side of the unit and is used to toggle Ports 

1

 through 

48

 

between link/activity and VCID display modes.

10/100Base-T Ethernet Interfaces

The NetVanta 1238P front panel contains 48 10/100Base-T Ethernet interfaces (RJ-45). These 
interfaces are arranged in stacked pairs, with the numbers 

1

 through 

48

 screened directly above the 

corresponding port. Status LEDs for each stacked pair are located directly over the interfaces. 

100/1000Base-T Gigabit Ethernet Interfaces

The front panel contains two 100/1000Base-T Gigabit Ethernet interfaces (RJ-45) labeled 

G1

 and 

G2

Status LEDs 

G1

 and 

G2 

are shared with SFP slots 

G1

 and 

G2

 and are located above the SFP slots. 

SFP Slots

The front panel contains four standard SFP slots for fiber connectivity numbered 

G1

 through 

G4

 with 

Status LEDs located directly above the slots. SFP slots 

G1

 and 

G2

 are associated with the Gigabit 

Ethernet (RJ-45) interfaces numbered 

G1

 and 

G2

 and share status LEDs. (Use either the RJ-45 

connectors for up 100/1000 Mbps copper connectivity or the SFP slots for 1 Gbps fiber connectivity. 
The SFP slots have precedence.) Slots 

G3

 and 

G4

 provide fiber connectivity at 1 or 2.5 Gbps.

NetVanta 1248P

G1 G2 G3 G4

1

3

2

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

24

23

25

26

27

28

29

30

32

31

33

34

35

36

37

38

40

39

41

42

43

44

45

46

48

47

STAT

LINK/ACT

PoE

VCID

G3

G1

G4

G2

Содержание NetVanta 1234

Страница 1: ...NetVanta 1230 Series Fast Ethernet Switch Hardware Installation Guide 1703594G1 NetVanta 1234 1703595G1 NetVanta 1234P 1702599G1 NetVanta 1238P 61702594G1 34D July 2014...

Страница 2: ...this publication Software Licensing Agreement Each ADTRAN product contains a single license for ADTRAN supplied software Pursuant to the Licensing Agreement you may a use the software on the purchase...

Страница 3: ...1 34D Copyright 2014 ADTRAN Inc 3 Conventions Notes provide additional useful information Cautions signify information that could prevent service interruption or damage to the equipment Warnings provi...

Страница 4: ...5 The socket outlet shall be installed near the equipment and shall be easily accessible If any of the following conditions occur unplug the product from the electrical outlet and replace the part or...

Страница 5: ...electriques applicables aux appareils num riques de Class A prescrites dans la norme sur le materiel brouilleur Appareils Num riques NMB 003 edictee par le ministre des Communications Toll Fraud Liabi...

Страница 6: ...Service and Warranty NetVanta 1230 Series Hardware Installation Guide 6 Copyright 2014 ADTRAN Inc 61702594G1 34D...

Страница 7: ...ntroduction 13 Physical Descriptions 14 NetVanta 1230 Series 14 Power over Ethernet 14 SFP Module Slots 14 Product Specifications 21 Unit Installation 22 Tools Required 22 Mounting Options 23 Supplyin...

Страница 8: ...Table of Contents NetVanta 1230 Series Hardware Installation Guide 8 Copyright 2014 ADTRAN Inc 61702594G1 34D...

Страница 9: ...Front Panel Layout 15 Figure 2 NetVanta 1234 Rear Panel Layout 16 Figure 3 NetVanta 1234P Front Panel Layout 16 Figure 4 NetVanta 1234P Rear Panel Layout 17 Figure 5 NetVanta 1238P Front Panel Layout...

Страница 10: ...List of Figures NetVanta 1230 Series Hardware Installation Guide 10 Copyright 2014 ADTRAN Inc 61702594G1 34D...

Страница 11: ...Copyright 2014 ADTRAN Inc 11 List of Tables Table 1 Front Panel LED Descriptions 20 Table A 1 10 100Base T Ethernet Port Pinouts 27 Table A 2 SFP Slot Pinouts 27 Table A 3 1000Base T Gigabit Ethernet...

Страница 12: ...List of Tables NetVanta 1230 Series Hardware Installation Guide 12 Copyright 2014 ADTRAN Inc 61702594G1 34D...

Страница 13: ...Product Specifications on page 21 Unit Installation on page 22 For additional information on mounting options and suppling power refer to the following sections Mounting Options on page 23 Supplying P...

Страница 14: ...e IEEE 802 3af PoE standard By default the PoE switches discover and provide power to IEEE compliant PDs NetVanta 1230P Series PoE supports legacy PoE The NetVanta 1230P Series units support a maximum...

Страница 15: ...4 are located above the 10 100 Base T Ethernet interfaces and indicates when there is activity on the interface 10 100Base T Ethernet Interfaces The front panel contains 24 10 100Base T Ethernet inter...

Страница 16: ...below Table 1 on page 20 describes all of the LEDs and Appendix A on page 27 shows the connector pinouts Figure 3 NetVanta 1234P Front Panel Layout NetVanta 1234P Front Panel Features Status LED The S...

Страница 17: ...LEDs G1 and G2 are shared with SFP slots G1 and G2 and are located above the SFP slots SFP Slots The front panel contains four standard SFP slots for fiber connectivity numbered G1 through G4 with St...

Страница 18: ...0 100Base T Ethernet Interfaces The NetVanta 1238P front panel contains 48 10 100Base T Ethernet interfaces RJ 45 These interfaces are arranged in stacked pairs with the numbers 1 through 48 screened...

Страница 19: ...e connector NetVanta 1238P Rear Panel Design The NetVanta 1238P rear panel is shown below Refer to Appendix A on page 27 for pinouts Figure 6 NetVanta 1238P Rear Panel Layout NetVanta 1238P Rear Panel...

Страница 20: ...isplayed Green solid Link status activity status is being displayed PoE Off PoE status is not being displayed Green solid PoE status is being displayed VCID Off VCID is not selected Green solid VCID i...

Страница 21: ...panel 1 1 1 Spanning Tree Support 802 1D and 802 1w Link Aggregation 802 3ad VLAN Support 802 1Q up to 255 active VLANs Priority QoS 802 1p Management Console Telnet CLI SSH CLI SNMP V2 Port mirroring...

Страница 22: ...Ethernet cables are intended for intrabuilding use only Connecting an ADTRAN unit directly to Ethernet cables that run outside the building in which the unit is housed will void the user s warranty an...

Страница 23: ...unting rack when installing this product Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading the circuit might have on overcurrent pr...

Страница 24: ...cessible Instructions for Wall Mounting the NetVanta Step Action 1 Remove the mounting brackets For a non PoE 1234 installation rotate them 90 degrees and reattach the mounting brackets to the chassis...

Страница 25: ...rovided with a power cable for your system purchase a power cable that is approved for use in your country The power cable must be rated for the product and for the voltage and current marked on the p...

Страница 26: ...y to be configured and connected to the network For information on switch configuration for a specific application refer to the configuration guides provided on the ADTRAN Support Community For detail...

Страница 27: ...Ethernet Port Pinouts Pin Name Description 1 TX1 Transmit Positive 2 TX2 Transmit Negative 3 RX1 Receive Positive 4 5 Unused 6 RX2 Receive Negative 7 8 Unused Table A 2 SFP Slot Pinouts Pin Name Pin N...

Страница 28: ...le A 3 1000Base T Gigabit Ethernet Port Pinouts Pin Name Description 1 TRD0 Transmit Receive Positive 2 TRD0 Transmit Receive Negative 3 TRD1 Transmit Receive Positive 4 TRD2 Transmit Receive Positive...

Отзывы: