background image

Warranty

: ADTRAN will replace or repair this product within the warranty period if it does not 

meet its published specifications or fails while in service. Warranty information can 

be found online at 

www.adtran.com/warranty

.

©2015 ADTRAN, Inc. All Rights Reserved.

*61287735G3-22B*

R

EGISTRATION

 ID

There are two methods where the OLT will register the ONT:

Serial Number Activation (performed by the OLT when the ONT 
is “Discovered”)

Set Registration ID Activation using Lineman’s handset (see 
below)

Set Registration ID Activation

To set the Registration ID using a DTMF Keypad on a standard telco 
Lineman’s handset, complete the following steps:

1. Verify the PON fiber-feed is disconnected from the ONT.
2. Press the 

RESET

 button on a previously powered-up ONT, or 

perform an initial power-up on a new ONT.

3. Wait approximately one minute for the start-up to complete, 

(

PWR

 LED is ON and solid; 

LOS

 LED is ON and solid).

4. Attach the handset to the 

POTS

 Port 1 and go off-hook.

5. Observe that the reorder tone (fast busy) is generated.

NOTE

The Reorder tone is continuously played after going off-hook until
the valid Registration ID password is dialed. See Step 6.

6. On the keypad, dial the registration ID password: 

*123#

.

7. Observe that the special information tone is generated.

NOTE

This is a fast “Hi-Mid--Low” tone that repeats.

8. On the keypad, press 

*

 to initiate the Registration ID input 

sequence.

9. Observe that the special information tone stops.

10. Dial the remainder of the Registration ID sequence: 

10

 

digit

 

plus 

#

.

NOTE

If the Registration ID entered is not valid, the Special Information
tone will be re-played. An incorrect Registration ID can be changed
by re-entering the Registration ID password (

*123#

) and then re-

entering a correct Registration ID sequence.

11. Wait 2 seconds. A confirmation tone is generated by the 

handset. This indicates a valid Registration ID was entered.

12. Hang-up the handset.
13. Push the 

RESET

 button, or power-cycle the ONT.

14. Connect the fiber between the PON and ONT.
15. The ONT should begin Ranging with the new Registration ID. 

The 

NET

 LED will be solid and the 

LOS

 LED will blink during 

ranging. The 

NET

 and 

MGT

 LEDs will become solid and the 

PON

2

2

Off
Green
Green Flashing 
Slow
Green Flashing Fast

ONT is not ranged
ONT is ranged
Ranging in progress

Software download in progress

Label

Status

Indication

LOS

 LED will extinguish once the ONT has successfully 

activated. This will take approximately 10-20 seconds.

16. Once the ONT has Ranged on the PON, the handset 

Registration ID process is disabled.

NOTE

If AOE Auto Upgrade is active, a new ONT installation will be
detected and a fast blinking 

PON

 LED will indicate a new software

download has commenced. This may take 5 - 10 minutes to complete.

S

PECIFICATIONS

Refer to the following for a list of all specifications for the Indoor SFU 
ONT.

Electrical

Voltage: 12 Volts typical

Minimum Voltage: 10 Volts

Maximum Voltage: 13.9 Volts

Power Consumption: Typical 7.2 watts

Physical

10.0 inches wide (25.5 centimeters)

5.9 inches deep ((15.0 centimeters)

 1.5 inches high (3.7 centimeters)

Weight: 1 pounds (0.45 kilograms)

Environmental

Operational Temperature: 23°F to +113°F (–5°C to +45°C)

Storage Temperature: –40°F to 185°F (–40°C to +85°C)

Relative Humidity: 90%, noncondensing

Optical

TX min power: 0.5 dBm

TX max power: 5.0 dBm

RSSI max sensitivity: -27 dBm

RX overload: -8 dBm

TX wavelength: 1310 nm typical

RX wavelength: 1490 nm typical

M

AINTENANCE

The Indoor 3rd Generation SFU ONT does not require routine 
hardware maintenance for normal operation. ADTRAN does not 
recommend that repairs be attempted in the field. Repair services 
may be obtained by returning the defective unit to ADTRAN. Refer to 
the warranty for further information. Field support for software is 
provided through upgrade facilities.

S

AFETY

 

AND

 R

EGULATORY

 C

OMPLIANCE

Refer to the Total Access 300 Series

 

Indoor 3rd Generation SFU ONT

 

Safety and Regulatory Compliance Notice

 (61287735G3-17) for detailed 

safety and regulatory information.

C A U T I O N 

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

 ADTRAN CUSTOMER CARE:

From within the U.S.     1.800.726.8663

From outside the U.S. +1 256.963.8716

PRICING AND AVAILABILITY  1.800.827.0807

Отзывы: