Chapter 2. Installation
2-2
Express 3010/3110 User Manual
61200239L1-20
Verify Switch Settings
Dip switches 1 and 2 located on the rear panel of the Express 3010/
3110 allow you to physically configure certain settings. Figure 2-2
shows the location of the dip switches on the rear panel of the unit.
The factory default position for all switches is down (On) during ini-
tial installation.
If switch 1 is set to the Off position, the unit is set to operate at a DTE
rate of 230.4 kbps. A special COM port using a 16650 UART is re-
quired while in this mode. If switch 1 is set to the On position, the unit
will automatically adapt to the DTE rate (up to 115.2 kbps).
If switch 2 is set to the Off position (up), the unit continues to use the fac-
tory default settings until switch 2 is set to the On position (down). Also,
area code, phone numbers, SPIDS, and stored numbers are cleared.
If both switches are up, the unit is offline in Command Mode.
Figure 2-2. Dip Switches on Rear Panel
SW 1:
Off (Up)
= 230.4 kbps
On (Down)
= Autobaud (speeds up to 115.2 kbps)
SW 2:
Off (Up)
= Factory Default
On (Down)
= Normal (previous settings saved)
OFF
EIA232
PWR
ISDN
2
1
OFF
ON
1
2
1
2
ON
12VDC
Содержание Express 3010
Страница 20: ...xx Express 3010 3110 User Manual 61200239L1 20 List of Figures and Tables ...
Страница 26: ...Chapter 1 Overview 1 6 Express 3010 3110 User Manual 61200239L1 20 ...
Страница 36: ...Chapter 2 Installation 2 10 Express 3010 3110 User Manual 61200239L1 20 ...
Страница 88: ...Appendix B LEDs B 2 Express 3010 3110 User Manual 61200239L1 20 ...
Страница 102: ...Appendix C Status Buffer Messages C 14 Express 3010 3110 User Manual 61200239L1 20 ...
Страница 106: ...Appendix D Loop Status Messages D 4 Express 3010 3110 User Manual 61200239L1 20 ...
Страница 114: ...61200239L1 1 Express 3010 3110 User Manual Index 6 Index ...