ADTRAN D4 U-BR1TE V Скачать руководство пользователя страница 8

8

Section 61104020L4-5, Issue 3

61104020L4-5C

The front panel bantam jacks accommodate standard
DS0 Logic Testers such as the TPI 108/109 RT II or
FIREBERD 4000/6000 which perform both the
upstream and downstream testing.

NOTE

On  DDS  circuits  the  internal  2047  Pattern
Generator on the U-BR1TE V should be used
only when the service is operating at 64 kbps.  If
DDS service is operating at 56 kbps or less, the
U-BR1TE V will display errors if the internal
2047  Pattern  Generator  is  used.    The  use  of
external DDS test equipment is required for all
data rates at 56 kbps and below.

Loopback Tests (ADR1 - ADR6, NT1)

Loopbacks in the Network-to-Customer direction can
be initiated from either the ISDN switch or the front
panel.  Either the internal 2047 test pattern or a DS0
digital test set provide the 64 kbps test pattern to be
tested in B1 or B2.  When initiating loopbacks from
the U-BR1TE V front panel, the downstream direction
is automatically selected based on the card position in
the network.

To initiate a loopback using the internal 2047 test
pattern, perform the following:

1. Select the desired loopback address using the ten-

position rotary switch.  See Table 2.

2. Select the desired bearer channel using the B1/B2

DIP switch.

3. Select PTRN on the NORM/PTRN DIP switch.

4. Depress the recessed TEST pushbutton to initiate

the test.  The TEST LED will illuminate GREEN
when the loopback is established to the selected
address, and the ERR LED should go out
following synchronization to the test pattern.  If
the selected address does not respond, the TEST
LED will remain out and the ERR LED will
illuminate.

5. To insert one bit error, momentarily  (for less

than two seconds) depress the TEST pushbutton.
The ERR LED should flash upon receipt of the
injected error.

6. Tests to additional network addresses may be

performed by changing the selector knob to the
desired address.  It is not necessary to exit the test
mode to select a new address.

7. To deactivate the loopback, depress the TEST

pushbutton for two seconds, until the GREEN
TEST LED is extinguished, or select NORM on
the NORM/PTRN DIP switch.

To initiate a loopback at any data rate when using an
external DS0 digital test set, perform the following:

1. Insert the TX and RX bantam plug of the DS0

digital test set into the U-BR1TE V respective
front panel bantam jacks.  Connect the clock
input of the DS0 digital test set to the channel
bank’s clock source (the D4 OIU, or the SLC-96
SSU).  Configure the test set for Near Logic and
64 kbps.

2. Select the desired loopback address using the ten-

position rotary switch.  See Table 2.

3. Select the desired bearer channel using the B1/B2

DIP switch.

4. Depress the recessed TEST pushbutton to initiate

the test.  The TEST LED will illuminate
YELLOW when the loopback is established to
the selected address.  If the selected address does
not respond, the TEST LED will remain off.
Observe the DS0 digital test set for bit errors.

5. Tests to additional network addresses may be

performed by changing the selector knob to the
desired address.  It is not necessary to exit the test
mode to select a new address.

6. To deactivate the loopback, depress the TEST

pushbutton or remove the transmit bantam plug.
Upon deactivation of the test, the TEST LED will
go out.

Point-to-Point Test (CRTX, LPTX)

A point-to-point (straight-away) test can be performed
to either the U-interface (LPTX) or the T-1 carrier
interface (CRTX).  In both cases, either the internal
2047 test pattern generator or a DS0 DP digital test set
is used to verify the performance of the selected
bearer channel.

To initiate a point-to-point test using the internal 2047
test pattern, perform the following:

1. Select the desired test direction, LPTX or CRTX,

using the ten-position rotary switch.  See Table 2.

2. Select the desired bearer channel using the B1/B2

DIP switch.

3. Select PTRN on the NORM/PTRN DIP switch.

Содержание D4 U-BR1TE V

Страница 1: ...cations Clear channel capability B8ZS is not required of the T1 facility if zero byte substitution is enabled The U BR1TE V plugs into a single channel slot of the D4 bank but can require three time s...

Страница 2: ...es three time slots In a D4 or SLC 96 Mode III channel bank it occupies the time slot associated with the physical channel slot that it occupies plus the next two time slots to the right The physical...

Страница 3: ...d D only occupies only the two time slots associated with the physical slot used In this configuration option the unit for Slot 1 4 7 or 10 Figure 2 Backplane Pin Assignments 28 29 30 31 32 33 34 35 3...

Страница 4: ...of the U BR1TE V Figure 5 SW1 SW3 and SW6 Labeling 1 TRM B1 B2 D ZBS DIS 1 O N 2 2 3 4 5 6 O N ZBS EN LUNT COT 1 TRM B1 B2 D ZBS DIS 2 3 4 5 6 O N ZBS EN 1 O N 2 LUNT COT SW1 SW3 TANDEM LULT RT ADJ T...

Страница 5: ...s e b d l u o h s h c t i w s s i h T s i h T n o i t a r u g i f n o c e c r u o S e c i f f O m e d n a T r o r e m o t s u C o t t n e c a j d A r e t a e p e R U e c i f f O m e d n a T d n a h c...

Страница 6: ...n Switch Settings at Network Locations for ISDN Applications 2 Wire 2 Wire T1 2 Wire 2 Wire T1 2 Wire T1 2 Wire 2 Wire T1 ISDN Switch D4 Channel Bank Customer NT1 D4 SLC 96 RT Channel Bank Adjacent to...

Страница 7: ...a l F Testing will flash yellow when BER 10 6 is e e s g n i r o t i n o M 0 1 R E B a n e h w w o l l e y e t a n i m u l l i d n a d e t c e t e d 5 d e t c e t e d s i R C s u t a t S r e i r r a C...

Страница 8: ...anging the selector knob to the desired address It is not necessary to exit the test mode to select a new address 7 To deactivate the loopback depress the TEST pushbutton for two seconds until the GRE...

Страница 9: ...attern 511 2047 If the far end unit is a U BR1TE V using the internal 2047 test pattern perform steps 1 through 4 of the previous section 6 Observe the DS0 digital test set for bit errors 7 To deactiv...

Страница 10: ...the in band DDS loopback commands The U BR1TE V responds to latching loopback sequences for the DS0 DP The U BR1TE V allows the OCU loopback command to pass in band downstream to the IDSL OCU R Upon...

Страница 11: ...and CSU latching loopbacks 1 Minimum of 35 transition in progress TIP bytes X0111010 2 Minimum of 35 loopback select code LSC bytes DS0 DP X0000101 OCU X1010101 CSU X0110001 3 Minimum of 100 loopback...

Страница 12: ...the U BR1TE toward the customer See Figure 10 This allows data to be sent from the remote end to test the local loop and the OCU R This loopback is indicated by a flashing CUST LBK LED on the IDSL OC...

Страница 13: ...rvices to ISDN equipment By using the 2 wire ISDN interface for 128 kbps data rate the U BR1TE V Leased Mode Operation allows pair savings over traditional DDS deployment DDS Frame Relay support allow...

Страница 14: ...sales Applications Post sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for Repair Upgrade 256...

Отзывы: