Section 61104020L4-5, Issue 3

61104020L4-5C

Figure 6

 displays the position switch settings at

network locations.

Front Panel Features

The U-BR1TE V front panel features a two position
DIP switch, a recessed pushbutton, a rotary switch, a
bantam jack, and LEDs, as illustrated in Figure 1.
The B1/B2 DIP Switch selects the desired bearer
channel, B1 or B2, to be tested during local tests
using the U-BR1TE V front panel.

The NORM/PTRN DIP Switch is recessed to prevent
inadvertent operation.  The ten-position rotary switch
is used to determine the specific test that will be
performed, including downstream loopbacks
(see 

Table 2

).

LED indicators display current status of the unit, as
listed in 

Table 3

.

Figure 6.  Position Switch Settings at Network Locations for ISDN Applications

2-Wire

2-Wire

T1

2-Wire

2-Wire

T1

2-Wire

T1

2-Wire

2-Wire

T1

ISDN

Switch

D4

Channel

Bank

Customer

NT1

D4/SLC-96

RT

Channel

Bank

Adjacent to 

Switch

Tandem Office 

(Source)

Tandem Office (Sink)

Adjacent to Customer

D4

Channel 

Bank

D4/SLC-96

COT

Channel

Bank

L

U

L
T

L

U

L
T

L

U
N

T

L

U
N

T

D4/SLC- 96

COT

Channel

Bank

D4/SLC-96

RT

Channel

Bank

Adjacent to

Switch

Adjacent to

Customer

Adjacent to

Switch

Adjacent to

Customer

L

U

L
T

L

U
N

T

Customer

NT1

Note: 

Refer to Table 1 for switch 
function descriptions.

D4/SLC-96

COT

Channel

Bank

D4/SLC-96

RT

Channel

Bank

L

U

L
T

L

U
N

T

2-Wire

Loop

Customer

NT1

ISDN

RP

    

   SW3    

1 - LUNT (COT)
2 - ADJ

    

   SW3    

1 - LULT (RT)
2 - ADJ       

    

   SW3    

1 - LUNT (COT)
2 - ADJ

    

   SW3    

1 - LULT (RT)
2 - ADJ

    

  SW3    

1 - LUNT (COT)
2 - ADJ

    

  SW3    

1 - LULT (RT)
2 - TANDEM

    

  SW3    

1 - LUNT (COT)
2 - TANDEM

    

  SW3    

1 - LULT (RT)
2 - ADJ

SW6

Norm

SW6

Power

SW6

Norm

SW6

Norm

SW6

Norm

SW6

Norm

SW6

Norm

SW6

Norm

Содержание D4 U-BR1TE V

Страница 1: ...cations Clear channel capability B8ZS is not required of the T1 facility if zero byte substitution is enabled The U BR1TE V plugs into a single channel slot of the D4 bank but can require three time s...

Страница 2: ...es three time slots In a D4 or SLC 96 Mode III channel bank it occupies the time slot associated with the physical channel slot that it occupies plus the next two time slots to the right The physical...

Страница 3: ...d D only occupies only the two time slots associated with the physical slot used In this configuration option the unit for Slot 1 4 7 or 10 Figure 2 Backplane Pin Assignments 28 29 30 31 32 33 34 35 3...

Страница 4: ...of the U BR1TE V Figure 5 SW1 SW3 and SW6 Labeling 1 TRM B1 B2 D ZBS DIS 1 O N 2 2 3 4 5 6 O N ZBS EN LUNT COT 1 TRM B1 B2 D ZBS DIS 2 3 4 5 6 O N ZBS EN 1 O N 2 LUNT COT SW1 SW3 TANDEM LULT RT ADJ T...

Страница 5: ...s e b d l u o h s h c t i w s s i h T s i h T n o i t a r u g i f n o c e c r u o S e c i f f O m e d n a T r o r e m o t s u C o t t n e c a j d A r e t a e p e R U e c i f f O m e d n a T d n a h c...

Страница 6: ...n Switch Settings at Network Locations for ISDN Applications 2 Wire 2 Wire T1 2 Wire 2 Wire T1 2 Wire T1 2 Wire 2 Wire T1 ISDN Switch D4 Channel Bank Customer NT1 D4 SLC 96 RT Channel Bank Adjacent to...

Страница 7: ...a l F Testing will flash yellow when BER 10 6 is e e s g n i r o t i n o M 0 1 R E B a n e h w w o l l e y e t a n i m u l l i d n a d e t c e t e d 5 d e t c e t e d s i R C s u t a t S r e i r r a C...

Страница 8: ...anging the selector knob to the desired address It is not necessary to exit the test mode to select a new address 7 To deactivate the loopback depress the TEST pushbutton for two seconds until the GRE...

Страница 9: ...attern 511 2047 If the far end unit is a U BR1TE V using the internal 2047 test pattern perform steps 1 through 4 of the previous section 6 Observe the DS0 digital test set for bit errors 7 To deactiv...

Страница 10: ...the in band DDS loopback commands The U BR1TE V responds to latching loopback sequences for the DS0 DP The U BR1TE V allows the OCU loopback command to pass in band downstream to the IDSL OCU R Upon...

Страница 11: ...and CSU latching loopbacks 1 Minimum of 35 transition in progress TIP bytes X0111010 2 Minimum of 35 loopback select code LSC bytes DS0 DP X0000101 OCU X1010101 CSU X0110001 3 Minimum of 100 loopback...

Страница 12: ...the U BR1TE toward the customer See Figure 10 This allows data to be sent from the remote end to test the local loop and the OCU R This loopback is indicated by a flashing CUST LBK LED on the IDSL OC...

Страница 13: ...rvices to ISDN equipment By using the 2 wire ISDN interface for 128 kbps data rate the U BR1TE V Leased Mode Operation allows pair savings over traditional DDS deployment DDS Frame Relay support allow...

Страница 14: ...sales Applications Post sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for Repair Upgrade 256...

Отзывы: