4
61287781F1C-13A
Step 3: Connect Ethernet
The C424G ONU supports four, 1 Gigabit (10/100/1000Base-T) connections (1 to 4).
If Ethernet cables are not available, use the following procedure and table to create the Ethernet cables:
1. Trim the insulation for the subscriber Ethernet cable.
2. Using a CAT 6 cable, connect the wires per the following table using an RJ-45 Crimper.
3. Refer to
and insert the CAT 6 rated cable in the appropriate Ethernet port.
Step 4: Connect Power
and plug the 12 VDC Power Adapter (supplied with the unit) into the
12V DC2.5A
connection on the rear of the chassis.
Connect the AC plug to a standard 120 VAC outlet.
Step 5: Connect Uninterrupted Power Source (UPS)
The step is optional. The C424G ONU can typically use an un-interruptible power supply (UPS) if desired. Power is supplied to the
C424G ONU by a local power source with battery backup that utilizes the AC power at the customer premises. The UPS powers the
C424G ONU supplying continuous 12 VDC. Refer to the installation material that is provided with the UPS.
To connect UPS, refer to
and connect a UPS cable from the source to the UPS port on the rear of the unit.
g
NOTE
ADTRAN offers a UPS Cable assembly (P/N 1287402G1) for this connector.
The UPS Power/Alarm Connections Table below defines each pin on the connector.
UPS Power/Alarm Table
The following table below provides a pinout of the UPS connection.
If an UPS is being used and its internal battery is disconnected or fails, the C424G ONU is not protected from power outages, and will
send a “Battery Missing” alarm to the OLT.
Ethernet RJ-45 Pin-out
Pin
Name
Description
Color Code
1
TRD0+
Transmit/Receive Positive
White/Orange
2
TRD0-
Transmit/Receive Negative
Orange
3
TRD1+
Transmit/Receive Positive
White/Green
4
TRD2+
Transmit/Receive Positive
Blue
5
TRD2-
Transmit/Receive Negative
White/Blue
6
TRD1-
Transmit/Receive Negative
Green
7
TRD3+
Transmit/Receive Positive
White/Brown
8
TRD3-
Transmit/Receive Negative
Brown
Pin-Out
Description
Alarm
1
Power Input (+12 VDC)
-
2
UPS Status - On Battery
1
3
UPS Status - Battery Missing
2
4
Signal Return
-
5
Power 12 V Return
-
6
UPS Status - Replace Battery
3
7
UPS Status - Low Battery
4
8
No Connection
-