2

61287800F1-13A

2. Select the appropriate mounting bracket and using the holes in the 

mounting brackets as a template, mark the surface where the 
screws will attach the ADTRAN 602 to the plywood surface.

3. Secure the brackets to the sides of the ADTRAN 602 using the 

screws provided.

4. Secure the ADTRAN 602 to the plywood using two #6 to #10 wood 

screws, at least 3/4” in length. 

Step 2: Ground the ADTRAN 602

To ground the ADTRAN 602, refer to the illustration on the first page and 
complete the following steps:

1. Attach a minimum 18 

AWG

 ground strap to the Chassis Ground 

using a UL approved ring lug and anti-rotational device (star 
washer).

2. Tighten the ground strap using the 1/4 inch nut supplied with the 

ADTRAN 602.

3. Connect the other end of the ground strap to a known, reliable 

ground at the installation site/location.

4. Using an ohmmeter, verify continuity between the ground lug and 

known good frame ground. The reading should be less than 1 ohm.

Step 3: Clean the LAN or WAN Connections

To clean the Customer 

LAN

 or 

WAN

 connections for the ADTRAN 602, 

refer to the illustration on the first page and complete the following steps:

1. Clean Optical interfaces of the appropriate SFP+/XFP.

f

     

CAUTION!

Do not allow disconnected optical connectors to touch surrounding 
unrelated surfaces and do not touch optical surfaces for any reason 
other than while performing the cleaning process.

Do not use compressed air to clean optical connectors.

Clean the optical surfaces as follows:

Use a fiberscope or videoscope to verify proper cleaning of 
connectors prior to connecting components together.

Use pure alcohol (reagent grade, 99.5% pure) when cleaning the 
endface of connectors. The alcohol can be applied with either 
laboratory grade lint-free tissues or with pre-moistened optical 
grade wipes.

Use microporous fabric spiral wrapped cleaning tips to clean 
bulkhead ferrules.

g

     NOTE

The following are guidelines for installing the 

SFP/XFP

:

The latch on the SFP/XFP is for removal only. When removing the
SFP/XFP, rotate the latch away from the SFP/XFP cage until a
physical click occurs. The SFP/XFP should slide easily out of the cage.

Always have dust caps and dust plugs installed when connectors or

adapters are not mated. Store dust caps in a sealable plastic bag
when not in use.

Step 4: Install SFP+ or XFP

To install the SFP+ or XFP, complete the following steps:

1. Insert the appropriate SFP+ or XFP into the appropriate cage with 

the latch handle facing outward. Slide the SFP+ or XFP all the way 
into the SFP cage.

2. Using thumb and forefinger, exert adequate pressure to ensure the 

SFP+ or XFP is completely seated in the cage.

Phillips-head screw driver

Assorted tie wraps for securing cabling and wiring

For fiber optic connections, the following are required:

Fiber optical fusion splice tools

ODC

 Fiber cleaning tool

SC/UPC

 Fiber connector

Installation Steps

To install the ADTRAN 602, complete the following steps.

Step 1: Locate the ADTRAN 602

There are three options to install the ADTRAN 602: Desk Top, Rack 
Mount, and Wall Mount. All options are described below.

g

     NOTE

Included with the ADTRAN 602 is a 4-foot power cord. All installation 
locations should be within 4-feet of a wall outlet.

Desk Top Installation

The ADTRAN 602 can be located on a desktop. 

f

     

WARNING!

Ensure that the ADTRAN 602 does not come in contact with water or other 
liquids.

f

     

CAUTION!

Ensure that the ADTRAN 602 is not located in direct sunlight or next to 
any thermal obstructions.

Rack Mount Installation

Refer to 

Figure 1

 and perform the following steps: 

1. Select the appropriate mounting bracket and secure it to the side of 

the ADTRAN 602 in the orientation desired using the screws pro-
vided.

2. Secure the ADTRAN 602 to a rack using the appropriate mounting 

screws.

Figure 1. Attach Mounting Brackets

Wall Mount

Refer to 

Figure 1

 and perform the following steps: 

1. Prepare the mounting surface by attaching a board (typically ply-

wood, 1/4” to 1/2” thick) to the wall studs using appropriate lag bolts. 

Mounting Bracket
(P/N: 3265479-2E@E)

Mounting Bracket
(P/N: 3265937-1E@C)

Содержание 602

Страница 1: ...cluding the following UL CUL 60950 1 IEC 60950 1 EN 60950 1 AS NZS 60950 1 RoHS FCC Part 15 Class B IEEE 802 3 FRONT PANEL CONNECTIONS The following table describes the connections on the front panel INSTALLATION Before installing the ADTRAN 602 inspect it for damage If damage has occurred during shipping file a claim with the carrier and then contact ADTRAN For more information refer to the warra...

Страница 2: ...g the SFP XFP The latch on the SFP XFP is for removal only When removing the SFP XFP rotate the latch away from the SFP XFP cage until a physical click occurs The SFP XFP should slide easily out of the cage Always have dust caps and dust plugs installed when connectors or adapters are not mated Store dust caps in a sealable plastic bag when not in use Step 4 Install SFP or XFP To install the SFP o...

Страница 3: ...al Directional Coupler OMCI OpenManageTM Client Instrumentation ONT Optical Network Terminal PON Passive Optical Network SC UPC Standard Connector Ultra Physical Contact SFP Small Form factor Pluggable UPS Uninterruptible Power Supply TWDM Time and Wavelength Division Multiplexing WAN Wide Area Network XFP 10G Form factor Pluggable XGSPON Ten Gigabits Passive Optical Network Operational Specificat...

Страница 4: ...alisation de toute opération de maintenance Consultez les normes nationales régionales et locales sur les installations électriques pour connaître les exigences en matière de câblage pour l alimentation et la mise à la terre C ATTENTION Ce produit contient ou utilise un module laser de classe 1 qui est conforme à la FDA 21 CFR 1040 10 1040 11 et IEC 60825 1 Pour maintenir la conformité avec les no...

Отзывы: