Section 61179512L2-5, Issue 1

61179512L2-5A

Total Access 1000 RT. When deployment requires the
HDSL Repeater (HRE), this ICOT can also be
deployed with one HRE and a Total Access 1000 RT.

Architecture

The DS1 or DSX-1 input signal to the ICOT is
supplied from the network.  The HDSL signals are
provided to the local loop.

The ICOT terminates a DSX-1 network-side interface
from the COT or switch and converts the DSX-1
signal to 4-wire HDSL and adds span powering.  The
HDSL signal is delivered over two twisted copper
pairs to the Total Access 1000 RT system where the
HDSL signal is converted into 24 POTS services.

Provisioning, test access, and performance monitoring
for the ICOT are accessed through the DB-9 craft
interface port.

The Total Access 1000 RT system is comprised of an
outside plant (OSP) housing, HDSL Line Interface
Unit (HLIU), Power Supply Unit/Ring Generator
(PSU/RG), Bank Controller Unit (BCU), and POTS or
ISDN access modules.  Refer to the Total Access 1000
RT Installation and Maintenance Practice, P/N
61179001L1-5, for more information regarding these
units.

The HLIU card provides the network interface for the
Total Access 1000 RT system.  The HLIU passes span
power to the PSU/RG, and the PSU/RG terminates the
span power from the network and provides regulated
operating  voltages to all components within the Total
Access 1000 RT system.  Also, the HLIU terminates
the HDSL signal, converts it to a DSX-1 level signal,
and passes it to the BCU.  The BCU terminates the
DS0 level signals to the POTS cards.  The BCU
provides the remote access point for provisioning,
testing, and monitoring system performance.  The

BCU and the HLIU VT100 terminal screens can be
accessed at the network end of the HDSL loops via
the DB-9 craft interface port on the ICOT faceplate.

The Total Access 1000 RT system can be deployed in
an integrated DLC configuration (

Figure 2

)  or a

universal DLC configuration (

Figure 3

).  When used

in the IDLC mode, a switch provides a DSX-1 to the
ICOT, the ICOT converts the DSX-1 to HDSL and
adds span powering.  The Total Access 1000 RT
terminates the HDSL and span powering, converts the
HDSL to DSX-1, and provides up to 24 subscriber
interfaces. In the UDLC configuration, the Total
Access 1000 RT interoperates with the Total Access
1500 COT.  The Total Access 1500 COT provides the
twenty-four 2-wire interfaces to the switch and, in
turn, provides the DSX-1 interface to the ICOT.

The ICOT contains an onboard fuse.  If the fuse
opens, it supplies a -48 VDC voltage to the fuse alarm
bus and all faceplate indicators will be Off.  This fuse
is not designed to be replaced in the field.

The 3192 ICOT uses a DC-to-DC converter to derive
its internal logic  and span  powering voltages from
the -48 VDC office supply.  The 3192 ICOT can
span-power up to one HRE and Total Access 1000 RT
as listed above.  Span-powering voltages meet all
requirements of Class A2 voltages as specified by
Bellcore GR-1089-CORE.

2. INSTALLATION

After unpacking the unit, inspect it for damage. If
damage is noted, file a claim with the carrier, and then
contact ADTRAN.  Refer to 

Warranty and Customer

Service

.

Figure 2.  Integrated DLC Configuration

NO

NO

SX

SX

SYNC

SYNC

CRC

CRC

QM

QM

DISC

DISC

REM

REM

NO

NO

DSU

DSU

LBK

LBK

RX

RX

(OUT)

(OUT)

TX

TX

(IN)

(IN)

TRDDB

TRDDB

1291004

1291004

DDS

DDS

Total Re

ach

otal Reach

ON

ON

19.2

19.2

56

56

64

64

SC

SC

9.6

9.6
4.8

4.8
2.4

2.4
QM

QM
LLB

LLB

66

77

88

99

55

44

33

22

11

AP

AP

CUSTOM

TELECOM

E190349

Customer Premises

Central Office

or RT

 ICOT

Module

T1

TR-08

SF

or

ESF

HDSL

Total Access 1000 RT

System

Phone

Switch

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

750

1

BUSY

1

2

3

4

BUSY

1

2

3

4

BUSY

1

2

3

4

BUSY

1

2

3

4

BUSY

1

2

3

4

BUSY

2

3

4

POWER

RG ON

RG DIS

LOOP 1

LOOP 2

POTS

1179408L1

POTS

1179408L1

POTS

1179408L1

POTS

1179408L1

POTS

1179408L1

POTS

1179408L1

PSU

1179007L1

BCU

1175012L1

BCU

1175012L1

TEST

ALARM

A
D
M
I
N

S

S

S

S

S

C A U T I O N 

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Содержание 3192

Страница 1: ... this document are trademarks registered trademarks or trade names of their respective holders LP1 LP2 DSX ALM LBK H D S L R S 2 3 2 1179512L2 TA1000 ICOT 1 GENERAL This practice is an installation and maintenance guide for the 3192 Integrated Central Office Terminal ICOT P N 1179512L2 illustrated in Figure 1 This unit is to be used exclusively with the Total Access 1000 Remote P N 1179001L1 Revis...

Страница 2: ... Figure 3 When used in the IDLC mode a switch provides a DSX 1 to the ICOT the ICOT converts the DSX 1 to HDSL and adds span powering The Total Access 1000 RT terminates the HDSL and span powering converts the HDSL to DSX 1 and provides up to 24 subscriber interfaces In the UDLC configuration the Total Access 1000 RT interoperates with the Total Access 1500 COT The Total Access 1500 COT provides t...

Страница 3: ...C REM NO DSU LBK RX OUT TX IN TRDDB 1291004 DDS Total Reach ON 19 2 56 64 SC 9 6 4 8 2 4 QM LLB 6 6 7 7 8 8 9 9 5 5 4 4 3 3 2 2 1 1 AP CUSTOM TELECOM E190349 Customer Premises Central Office Total Access1500 with FXO Module ICOT Module T1 HDSL 2 Wire Total Access 1000 RT System Phone Switch S S S S S S S S S S S S S S S S S S S S S S S S 750 1 BUSY 1 2 3 4 BUSY 1 2 3 4 BUSY 1 2 3 4 BUSY 1 2 3 4 BU...

Страница 4: ... o r r e d e t c e t e D 2 P L f f O d e R w o l l e Y n e e r G g n i k n i l B n o i t a z i n o r h c n y s o N 1 2 p o o L n o y t i l a u q l a n g i s r o o P 0 7 R E B 2 p o o L n o y t i l a u q l a n g i s l a n i g r a M 1 e v o b a n i g r a m B d 2 0 7 R E B 1 e v o b a n i g r a m B d 2 2 p o o L n o y t i l a u q l a n g i s d o o G 0 7 R E B 2 p o o L f o d n e r e h t i e n o r o r...

Страница 5: ...w alarm 13 A digroup 5 SLC 96 D4 B C D digroup 1 ESF 3 Status 4 Statistics 2 Loopback to Network at ICOT 3 Loopback to Network at HLIU 4 BCU Line Loopback at RT 5 BCU Payload Loopback at RT 1 Self Test 2 900 ohms 3 600 ohms 2 16 Farads 4 900 ohms 2 16 Farads 5 Auto 1 600 ohms 2 Line Loopback 3 Payload Loopback 1 Stop Test 2 DSX 1 Line Coding 3 HDSL Loopback Timeout 1 Line Buildout 2 Transmit Atten...

Страница 6: ...all cases is a logic level loopback at the point within the ICOT where the DSX 1 signal passes into the HDSL modulators Figure 8 depicts all of the loopback locations possible with ADTRAN HDSL equipment Figure 8 Loopback Configurations Figure 7 Bantam Jack Arrangement DSX 1 MON RX ICOT DATA PUMP LOOP DC POWER SOURCE DSX 1 T1 R1 DSX 1 T R HDSL LOOP 1 HDSL LOOP 2 ICOT HDSL LOOP 1 HDSL LOOP 2 EQ RX D...

Страница 7: ...hin acceptable limits 5 If steps 1 through 4 pass and loop sync is still not available replace the unit with one known to be in proper working condition Condition All front panel indicators are Off Power is present and adequate but loop sync is not available LP1 and or LP2 LEDs are Off Figure 9 CSA Deployment Guidelines 0 12 11 10 9 8 7 6 5 4 3 2 1 0 1 2 3 4 WORKING LENGTH OF 26 GAUGE CABLE KFT WO...

Страница 8: ...ABAM 134 266 feet ABAM 267 399 feet ABAM 400 533 feet ABAM 534 655 feet ABAM DSX 1 Line Code AMI B8ZS DSX 1 Format SF ESF SLC 96 DSX 1 Channelization Channels 1 12 on HDSL Loop 1 Channels 13 24 on HDSL Loop 2 Power Tested with the ADTRAN Total Access 1000 RT P N 1179001L1 Total Power 48 VDC 273 mA with HTU R HTU C Power Dissipation 5 503 watts with HTU R Span Power 135 VDC Internally Generated cur...

Страница 9: ... S and Canada Carrier Networks Equipment Warranty document 60000087 10 Contact Customer And Product Service CAPS prior to returning equipment to ADTRAN For service CAPS requests or further information contact one of the following numbers ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Pre sales Applications Post sales Technical Assistance 800 726 8663 Standard hours Monday ...

Страница 10: ...10 Section 61179512L2 5 Issue 1 61179512L2 5A ...

Страница 11: ...cks Arm FF48 1111 1111 0100 1000 ESF facility data link ESF only when sent from the network all units will be armed and an HLIU network loopback will be activated This code has no functionality when sent from the customer Disarm 11100 also known as a 3 in 5 pattern All units are removed from the armed state If any of the units are in loopback when the 11100 pattern is received they will loop down ...

Страница 12: ...rors are injected if all HDSL receiver points ICOT LP1 LP2 HRE 1 NET LP1 LP2 HRE 1 CST LP1 LP2 and HLIU or Total Access 1000 RT LP1 LP2 indicate pulse attenuation is 30 or lower and signal quality margin is 6 dB or higher 11 errors at a time are injected if any of the 8 receiver points indicate pulse attenuation is greater than 30 dB and or signal quality margin is less than 6 dB Loopback Time Out...

Страница 13: ... deployment with the Total Access 1124 If the ICOT module is not being deployed with the Total Access 1124 remove this label from the front panel LP1 LP2 DSX ALM LBK H D S L R S 2 3 2 1179512L2 TA1000 ICOT LED is red and Craft port is inoperative when deployed with TA1124 Alarm Label 3192 Integrated Central Office Terminal ICOT Document Addendum for 61179512L2 5A ...

Отзывы: