Chapter 7. Test Menu
7-4
ESU LT User Manual
61200410L1-1
CLR ERRORS
CLR
ERRORS
has two functions.
1. It clears out the 511 error total when you press
Enter
.
2. It displays a total of the 511 errors. If 511 errors are being
received, the display is updated accordingly. See Figure
7-3.
Figure 7-3. Clear Errors Screen
This menu function is very useful for testing end-to-end
integrity of the network. First loop up the far end ESU LT.
Then send a 511 pattern from the local ESU LT. The
CLR
ERRORS
screen can then be used to determine if the link is
functioning properly by verifying that no errors are being
counted.
INSERT QRSS or 511 ERRORS
When running a 511 or QRSS pattern test, press
Enter
to
insert an error into the pattern.