C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty:
ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442703PG2-22B*
This
device
complies
with
Part
15
of
the
FCC
rules.
Operation
is
subject
to
the
following
two
conditions:
1. This
device
may
not
cause
harmful
interference.
2. This
device
must
accept
any
interference
received,
including
interference
that
may
cause
undesired
operation.
Changes
or
modifications
not
expressly
approved
by
ADTRAN
could
void
the
user
ʹ
s
authority
to
operate
this
equipment.
CAUTION
C
The
SFP
OC
‐
12
contains
a
Class
1
laser
that
complies
with
the
Laser
Safety
requirements
of
FDA
21
CFR
1040.10
and
1040.11,
and
EN
60825
‐
1,
and
‐
2.
The
SFP
OC
‐
12
is
NRTL
Listed
and
CB
Certified
to
all
applicable
American
and
European
safety
standards.
CAUTION
!
♦
Per
GR
‐
1089
‐
CORE
Section
9,
the
SFP
OC
‐
12
does not have
an internal DC connection between battery return and
frame ground.
♦
The
ADTRAN
system
that
the
SFP
OC
‐
12
is
being
deployed
in
is
designed
and
intended
for
installation
as
part
of
a
Common
Bonding
Network
(CBN),
or
Isolated
Bonding
network
(IBN).
♦
The
SFP
OC
‐
12
can
be
installed
in
a
DC
‐
I
(isolated)
or
DC
‐
C
(common)
configuration.
For
installations
where
other
cards
or
the
host
system
have
internal
connections
between
battery
return
and
frame
ground,
the
system
would
be
intended
for
deployment
only
in
a
DC
‐
C
configuration.
♦
The
ADTRAN
system
chassis
frame
ground
terminal
must
be
connected
to
a
reliable
earth
ground
to
ensure
that
the
metal
enclosure
of
the
SFP
OC
‐
12
is
properly
grounded
via
the
backplane
connector.
NOTE
♦
The
OC
‐
12
port(s)
are
optical
and
therefore
are
not
classified
as
any
type
of
port
as
defined
in
Appendix
B
of
GR
‐
1089
‐
CORE
Issue
5.
♦
This
SFP
OC
‐
12
is
compliant
with
SFF
‐
8472
“Digital
Diagnostics
Monitoring
Interface
for
Optical
Transceivers,”
Revision
9.3.
♦
This
SFP
OC
‐
12
is
compliant
with
the
Small
Form
‐
Factor
Pluggable
(SFP)
Multi
‐
Source
Agreement
(MSA).
♦
This
product
is
designed
to
be
deployed
in
GR
‐
3108
‐
CORE
environment
class
1
or
2
as
defined
in
GR
‐
3108
‐
CORE
issue
2.
The
SFP
OC
‐
12
is
designed
to
meet
the
following
environmental
classes:
♦
ETSI
EN
300
019
‐
1
‐
1
“Classification
of
environmental
conditions;
Storage,”
Class
1.2
♦
ETSI
EN
300
019
‐
1
‐
2
“Classification
of
environmental
conditions;
Transportation,”
Class
2.3
♦
ETSI
EN
300
019
‐
1
‐
3
“Classification
of
environmental
conditions;
Stationary
use
at
weather
‐
protected
locations,”
Class
3.3
This
product
has
been
evlauated
to
international
safety
standards
EN
60950
‐
1,
AS/NZS
60950.1,
and
IEC
60950
‐
1.
This
product
meets
the
requirements
for
CE
marking
under
the
EMC
Directive
and
Low
Voltage
Directive.
Standards
used
to
demonstrate
Compliance
are
EN
300
386
and
EN
60950.
The
equipment
is
designed
to
function
without
degradation
during
exposure
to
all
test
severities
per
Class
3.3.
www.adtran.com
for
further
infor
‐
mation
on