Installation
36
61287802F1-34B
Revision B
5. To terminate the 2 Power leads and, and if needed, the 5 alarm status leads, cut wire to
length and strip the insulation back 1/4 inch.
6. Loosen each retaining screw and insert the wire into the appropriate slot (see
on page 34 and
7. Tighten the retaining screws.
8. Reinstall the Power/Alarm Connector in the Electronics Module.
Figure 14. Power/Alarm Connector Installed
9. Tie wrap and route these wires as shown above. This will prevent the connector from
coming loose when the Electronics Module is closed.
5.3.5
Installation of the Power Supply
WARNING!
f
■ Before making any power connections to this equipment, verify the power is off (fuse
removed/breaker tripped).
■ This equipment should only be operated from the type of certified/listed power supply
supplied by the manufacturer with the equipment.
NOTE
g
When installing the UPS, refer to the UPS manufacturer’s mounting instructions where
possible.
7
SIG R
TN
ONT
BA
T
REP
BA
T
BA
T
MIS
LOW BA
T
12V R
TN
+12 VDC
6 5 4 3 2 1
Tie Wrap Wires as shown
Note:
Even though there are brackets
to position the Power / Alarm
Connector wires, their use is
not
recommended. Use of
these brackets can “bind” the
wires when the Electronics
Module is closed.
Power / Alarm Connector
Back of Electronics Module