T1 Interface
Capacity
1.544 Mbps (each)
Connection
RJ-48C jacks
Line Code
B8ZS, AMI
Framing
ESF, D4
Alarms
AIS, Red, Yellow, BPVs, LOS
Loopbacks
Local and remote (line and link)
User Interface
Panel
Alarm LEDs
Diagnostics
Line and Link Loopbacks
Test Points
RSSI and GND
Alarms
Normally Open (NO) and Normally Closed (NC)
VT100 Terminal
Menu Driven User Interface, Control of the Remote End,
Loopback Test, Optional Password Protection, Event
History
VT100 Terminal Interface
Data Rate
9600 bps
Data Bits
8
Parity
None
Stop Bits
1
Terminal Emulation
VT100
Mechanical and Environmental
Operating Temperature
-25° C to 65° C
Size
17.12” W x 9.34” D x 1.72” H
Humidity
95%, Non-condensing
Weight
9 lbs (TRACER 4102), 7 lbs (TRACER 4202)
Power
Input Voltage
21 to 60 VDC, either polarity referenced to ground
Power Consumption
< 20 Watts
Connector
2 pin terminal block (DC)
Fuse
1A, 250V slow-blo fuse (2-inch)
Table 9. At-A-Glance Specifications