61245001L6-5G
Section 61245001L6-5, Issue 7
11
Figure 10. Current System Status Screen
Figure 10A. Current System Status Screen - HRE
CIRCUIT ID: Circuit XXXXX 02/01/99 11:15:34
LOOP #1 <NETWORK> LOOP #2 CURRENT SYSTEM STATUS LOOP #1 <CUSTOMER>LOOP #2
-------- HRE #1 --------- -------- HRE #1 ---------
00 dB 00 dB <- LOSS -> 31 dB 30 dB
YES YES <- SYNC -> YES YES
000/00000 000/00000 <- ES 15M/24H -> 000/00000 000/00001
000/00000 000/00000 <- SES 15M/24H -> 000/00000 000/00000
000/00012 000/00012 <- UAS 15M/24H -> 000/00016 000/00012
LOOPBACK INACTIVE HRE CUST PAIRS REVERSED LOOPBACK INACTIVE
HRE#1 NET SIGNAL QUALITY N = NETWORK SIDE RECEIVER HRE#1 CUST SIGNAL QUALITY
[X] 9 [X] C = CUSTOMER SIDE RECEIVER [X] 9 [X]
L[X] 8 L[X] L[X] 8 L[X]
O[X] 7 O[X] ____ ____ ____ O[X] 7 O[X]
O[X] 6 O[X] |HTUC| LOOP1 |HRE1| LOOP1 |HTUR| O[X] 6 O[X]
P[X] 5 P[X] | |========N| |C========| | P[X] 5 P[X]
[X] 4 [X] | | | | | | [X] 4 [X]
1[X] 3 2[X] | |========N| |C========| | 1[X] 3 2[X]
[X] 2 [X] |____| LOOP2 |____| LOOP2 |____| [X] 2 [X]
[X] 1 [X] [X] 1 [X]
[X] 0 [X] [X] 0 [X]
Press “Z” to zero registers, “M” for Main Menu
“P” for previous view.
CIRCUIT ID: Circuit XXXXX 02/01/99 11:14:38
LOOP #1 <NETWORK> LOOP #2 CURRENT SYSTEM STATUS LOOP #1 <CUSTOMER>LOOP #2
-------- HTU-C ---------- -------- HTU-R ----------
02 dB 02 dB <-- LOSS --> 32 dB 32 dB
YES YES <-- SYNC --> YES YES
000/00000 000/00000 <-- ES 15M/24H --> 000/00000 000/00000
000/00000 000/00000 <-- SES 15M/24H --> 000/00000 000/00000
000/00012 000/00012 <-- UAS 15M/24H --> 000/00016 000/00016
LOOPBACKS INACTIVE LOOPBACKS INACTIVE
HTU-C SIGNAL QUALITY DSX-1 DS1 HTU-R SIGNAL QUALITY
[X] 9 [X] ------------------------------ [X] 9 [X]
L[X] 8 L[X] ESF <- FRAME -> ESF L[X] 8 L[X]
O[X] 7 O[X] B8ZS <- CODE -> B8ZS O[X] 7 O[X]
O[X] 6 O[X] 0-133 <- LBO -> 0 dB O[X] 6 O[X]
P[X] 5 P[X] N/A <- NIU -> YES P[X] 5 P[X]
[X] 4 [X] 00001 <- BPV -> 00001 [X] 4 [X]
1[X] 3 2[X] 00001 <- ES -> 00001 1[X] 3 2[X]
[X] 2 [X] 00000 <- SES -> 00001 [X] 2 [X]
[X] 1 [X] 00000 <- UAS -> 00000 [X] 1 [X]
[X] 0 [X] NONE <- ALARMS -> NONE [X] 0 [X]
SEALING CURRENT PRESENT
Press “Z” to zero registers, “M” for Main Menu
“H” for HDSL Range Extender #1 (HRE) View.
Содержание 1245001L6
Страница 20: ...20 Section 61245001L6 5 Issue 7 61245001L6 5G ...
Страница 24: ...A 4 Section 61245001L6 5 Issue 7 61245001L6 5G ...