Appendix H. Glossary
H-2
DSU IV ESP User Manual
61204011L1-1
CD
carrier detect. A signal generated by a modem or DSU/CSU. CD indicates the
presence of a carrier signal on a communications link.
channel service unit
CSU. A device used to connect a digital phone line (T1 or Switched 56 line) com-
ing in from the phone company to either a multiplexer, channel bank, or directly
to another device producing a digital signal; for example, a digital PBX, a PC, or
data communications device. A CSU performs certain line-conditioning and
equalization functions, and responds to loopback commands sent from the cen-
tral office. A CSU regenerates digital signals. It monitors them for problems, and
provides a way of testing the digital circuit.
CIR
committed information rate. Less than or equal to the access rate, the CIR is used
by the service provider for rate enforcement when the network is congested.
When rates exceed the CIR, frames may be discarded.
clocking
An oscillator-generated signal that provides a timing reference for a transmis-
sion link. A clock provides signals used in a transmission system to control the
timing of certain functions. The clock has two functions, (1) to generate periodic
signals for synchronization and (2) to provide a time base.
CPE
customer premise equipment. All telecommunications terminal equipment
located on the customer premises, including telephone sets, private branch
exchanges (PBXs), data terminals, and customer-owned coin-operated tele-
phones.
C/R bit
In the Q.921 protocols, a bit that identifies a data-link-layer frame as either a
command or a response.
CRC
cyclic redundancy check. A computational means to ensure the accuracy of
frames transmitted between devices in a frame relay network. The mathematical
function is computed, before the frame is transmitted, at the originating device.
Its numerical value is computed based on the content of the frame. This value is
compared with a recomputed value of the function at the destination device.
Содержание 1202011L1
Страница 1: ...DSU III AR Data Service Unit User Manual Part Number 1202011L1 61202011L1 1C May 2001...
Страница 18: ...Table of Contents xviii DSU III AR User Manual 61202011L1 1...
Страница 24: ...List of Tables xxiv DSU III AR User Manual 61202011L1 1...
Страница 72: ...Chapter 6 Configuring DTE Options 6 18 DSU III AR User Manual 61202011L1 1...
Страница 82: ...Chapter 9 Manual Command 9 4 DSU III AR User Manual 61202011L1 1...
Страница 110: ...Chapter 11 Testing and Troubleshooting 11 26 DSU III AR User Manual 61202011L1 1...
Страница 130: ...Appendix B AT Commands B 12 DSU III AR User Manual 61202011L1 1...
Страница 134: ...Appendix C Default Configuration Profiles C 4 DSU III AR User Manual 61202011L1 1...
Страница 136: ...Appendix D EIA 232 Connector D 2 DSU III AR User Manual 61202011L1 1...
Страница 140: ...Appendix E DSU to DSU Tail Circuit E 4 DSU III AR User Manual 61202011L1 1...
Страница 144: ...Appendix F Specifications Summary F 4 DSU III AR User Manual 61202011L1 1...
Страница 158: ...Appendix H Glossary H 10 DSU IV ESP User Manual 61204011L1 1...