NetVanta 3200/3300/3400 Series
Option Modules
61200860L1-34AE
Copyright © 2019 ADTRAN, Inc.
45
NetVanta T1/FT1 + DSX-1 NIM (P/N 1202863L1)
The NetVanta T1/FT1 + DSX-1 NIM (shown in
) provides a full T1 or fractional T1 network
interface and a DSX-1 interface. See
for the WAN-T1 connector pinouts,
for the DSX-1 connector pinouts, and
for the DBU connector pinouts.
An optional DIM is required for dial backup applications.
WAN-T1
DSX-1
DBU
Figure 19. NetVanta T1/FT1 + DSX-1 NIM
Features and Specifications
Operating Modes
•
Frame Relay, multilink Frame Relay
•
PPP, MLPPP
•
HDLC
T1/FT1 Interface
•
Supported Standards: AT&T TR 62411,
AT&T TR 65016, ANSI T1.403,
Bellcore TR 194
•
Line Rate: 1.544 Mbps +75 bps
•
Line Code: AMI or B8ZS
•
Framing: D4 (SF) or ESF
•
FT1 Line Rate: DS0 channelized (multiples
of 56/64 kbps)
•
Input Signal: 0 to -36 dB (DS1)
•
Line Build Out: 0, -7.5, -15, -22.5 dB
(long), 0 to 655 ft. (short)
•
DS0 Assignment: Programmable
•
Connector: RJ-48C
DSX-1 Interface
•
Line Interface: DSX-1 per ANSI T1.102
•
DSX Receiver Input Range: -10 dBdsx to
+6 dBdsx
•
Line Rate: 1.544 Mbps
•
Capacity: 1 to 24 DS0s
•
Line Codes: AMI, B8ZS
•
DSX-1 Interface to PBX
•
Framing: D4 (SF) or ESF
•
Line Length: 0 to 655 feet and -7.5 dB
•
Connector: RJ-48C
Clock Source
•
Network
•
Internal
•
Through
Diagnostics
•
Test Pattern Generation and Detection:
511, QRSS, all ones, all zeros
•
Network loopbacks (local and remote);
responds to inband and FDL loop codes (T1
interface only)
•
Alarm generation and detection
•
Network and user sets of performance data
(15 minutes and 24 hours)
Compliance
•
FCC Part 15 Class A
•
EN 55022 Class A
•
EN 55024
•
UL/CUL 60950-1
•
ACTA/FCC Part 68
•
IC CS-03
Environmental
•
Operating Temperature: 0°C to 50°C
•
Storage Temperature: -20°C to 70°C
•
Relative Humidity: Up to 95 percent,
noncondensing
Physical
•
Dimensions: 2.75-inch W x 4.25-inch D