NetVanta 5305 Hardware Installation Guide
Unit Installation
61200990L1-34P
Copyright © 2014 ADTRAN, Inc.
31
Figure 9. NetVanta VPN Accelerator Card Installation
Your NetVanta unit is now ready to be configured and connected to the network. For information on
configuration for a specific application, refer to the configuration guides provided online on
For details on the CLI, refer to the
AOS Command Reference Guide
. All other related documents
are also available online on
The NetVanta VPN Accelerator card is intended to be installed only by qualified service
personnel.
Instructions for Installing the VPN Accelerator Card
Step
Action
1
Remove power from the unit.
2
Use a screwdriver to take the screws out of the system controller module. Remove the module.
3
Gently slide the accelerator card into the PCI slot as shown. The card is keyed to fit into the slot
only one way. To avoid damaging the card pins, do not use excessive force.
4
Slide the system controller module into the controller slot until the module is firmly positioned
against the chassis.
5
Secure the screws at both edges of the module. Tighten with a screwdriver.
6
Restore power to the unit.
Содержание 1200831G1
Страница 10: ...Table of Contents NetVanta 5305 Hardware Installation Guide 10 Copyright 2014 ADTRAN Inc 61200990L1 34P ...
Страница 12: ...List of Figures NetVanta 5305 Hardware Installation Guide 12 Copyright 2014 ADTRAN Inc 61200990L1 34P ...
Страница 14: ...List of Tables NetVanta 5305 Hardware Installation Guide 14 Copyright 2014 ADTRAN Inc 61200990L1 34P ...
Страница 32: ...Unit Installation NetVanta 5305 Hardware Installation Guide 32 Copyright 2014 ADTRAN Inc 61200990L1 34P ...
Страница 36: ...Appendix A NetVanta 5305 Hardware Installation Guide 36 Copyright 2014 ADTRAN Inc 61200990L1 34P ...