background image

NetVanta 5305

Hardware Installation Guide

4200990L1

NetVanta 5305 AC System

4200990G1

NetVanta 5305 AC System (RoHS Compliant)

4200990G2

NetVanta 5305 AC System with Enhanced Feature Pack (RoHS Compliant)

4200992L1

NetVanta 5305 AC System with T3 Wide Module

4200995L1

NetVanta 5305 DC System

4200368L3

Enhanced Feature Pack (Hardware and Software) for IPsec VPN Upgrade

1200831G1

NetVanta 5305 System Controller Module (RoHS Compliant)

1200832L1

NetVanta T3 Wide Module

1200934L1

NetVanta HSSI Wide Module 

1202843E1

NetVanta Octal T1/E1 Wide Module

1200840G1#120

NetVanta 5305 AC Power Supply, 120 VAC

1200840G1#240

NetVanta 5305 AC Power Supply, 240 VAC

1200841G1

NetVanta 5305 DC Power Supply

61200990L1-34P
July 2014

Содержание 1200831G1

Страница 1: ... 4200995L1 NetVanta 5305 DC System 4200368L3 Enhanced Feature Pack Hardware and Software for IPsec VPN Upgrade 1200831G1 NetVanta 5305 System Controller Module RoHS Compliant 1200832L1 NetVanta T3 Wide Module 1200934L1 NetVanta HSSI Wide Module 1202843E1 NetVanta Octal T1 E1 Wide Module 1200840G1 120 NetVanta 5305 AC Power Supply 120 VAC 1200840G1 240 NetVanta 5305 AC Power Supply 240 VAC 1200841G...

Страница 2: ...lication Software Licensing Agreement Each ADTRAN product contains a single license for ADTRAN supplied software Pursuant to the Licensing Agreement you may a use the software on the purchased ADTRAN device only and b keep a copy of the software for backup purposes This Agreement covers all software installed on the system as well as any software available on the ADTRAN website In addition certain...

Страница 3: ... 34P Copyright 2014 ADTRAN Inc 3 Conventions Notes provide additional useful information Cautions signify information that could prevent service interruption or damage to equipment Warnings provide information that could prevent injury or endangerment to human life ...

Страница 4: ...They may explode Check with local codes for special disposal instructions 5 The socket outlet shall be installed near the equipment and shall be easily accessible If any of the following conditions occur unplug the product from the electrical outlet and replace the part or contact your qualified service personnel 1 The power cable extension cable or plug is damaged 2 An object has fallen into the ...

Страница 5: ... information The telephone company may require this equipment to be disconnected from the network until the problem is corrected or it is certain the equipment is not malfunctioning 5 This unit contains no user serviceable parts 6 This equipment is designed to connect to the telephone network or premises wiring using an FCC compatible modular jack which is compliant with Part 68 and requirements a...

Страница 6: ...cordance with the instruction manual may cause harmful interference to radio frequencies Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Electromagnetic Compatibility EMC Table NetVanta Module P N and Name NetVanta 5305 1200831G1 System Controller Module FCC Part 15 Clas...

Страница 7: ... of Communications Cet appareil numérique respecte les limites de bruits radioelectriques applicables aux appareils numériques de Class A prescrites dans la norme sur le materiel brouilleur Appareils Numériques NMB 003 edictee par le ministre des Communications Toll Fraud Liability Be advised that certain security risks are inherent in the use of any telecommunications or networking equipment incl...

Страница 8: ...Service and Warranty NetVanta 5305 Hardware Installation Guide 8 Copyright 2014 ADTRAN Inc 61200990L1 34P ...

Страница 9: ...0831L1 21 NetVanta T3 Wide Module P N 1200832L1 22 NetVanta HSSI Wide Module P N 1200934L1 23 NetVanta Octal T1 E1 Wide Module P N 1202843E1 24 T1 E1 Mode Switch 25 Unit Installation 26 Tools Required 26 Mounting Options 27 Rack Mounting NetVanta 5305 27 Installing Modules 28 Supplying Power to the Unit 29 NetVanta 5305 AC 29 AC Grounding Instructions 29 Redundant AC Power Supplies Optional 29 Net...

Страница 10: ...Table of Contents NetVanta 5305 Hardware Installation Guide 10 Copyright 2014 ADTRAN Inc 61200990L1 34P ...

Страница 11: ...5305 AC Rear Panel Layout 19 Figure 3 NetVanta 5305 DC Rear Panel Layout 19 Figure 4 NetVanta 5305 System Controller Module 21 Figure 5 NetVanta T3 Wide Module 22 Figure 6 NetVanta HSSI Wide Module 23 Figure 7 NetVanta Octal T1 E1 Wide Module 24 Figure 8 Rack Mounting the NetVanta 5305 27 Figure 9 NetVanta VPN Accelerator Card Installation 31 ...

Страница 12: ...List of Figures NetVanta 5305 Hardware Installation Guide 12 Copyright 2014 ADTRAN Inc 61200990L1 34P ...

Страница 13: ...e 1 NetVanta 5305 LEDs 18 Table A 1 10 100Base T Ethernet Port Pinouts 33 Table A 2 CONSOLE Port DCE Pinouts 33 Table A 3 T3 Wide Module T3 Interface BNC 34 Table A 4 HSSI Wide Module Pinouts 34 Table A 5 Octal T1 E1 Wide Module Pinouts for either T1 or E1 Mode 35 ...

Страница 14: ...List of Tables NetVanta 5305 Hardware Installation Guide 14 Copyright 2014 ADTRAN Inc 61200990L1 34P ...

Страница 15: ...es and Specifications The NetVanta 5305 has the following features Unchannelized T3 network access via the T3 Wide Module Integrated IP router with bridging WAN Protocol Frame Relay PPP Stateful inspection firewall standard RIP versions 1 and 2 and OSPF routing protocols Two integrated 10 100Base T Ethernet ports RJ 48C Optional VPN accelerator card Network Address Translation 1 1 1 many NAPT and ...

Страница 16: ...tents of ADTRAN Shipments NetVanta 5305 AC System Shipments of the NetVanta 5305 AC include the following items NetVanta 5305 AC IEC 3 prong power cord 19 inch rackmount kit Quick start guide NetVanta 5305 DC System Shipments of the NetVanta 5305 DC include the following items NetVanta 5305 DC DC Molex connector 19 inch rackmount kit Quick start guide NetVanta 5305 T3 Wide Module Shipments of the ...

Страница 17: ...lation Guide Product Overview 61200990L1 34P Copyright 2014 ADTRAN Inc 17 2 PRODUCT OVERVIEW Reviewing the Front Panel Design Figure 1 shows the NetVanta 5305 front panel Figure 1 NetVanta 5305 AC and DC versions Front Panel Layout ...

Страница 18: ...ial backup module is ready for use Green flashing Unit is in dial backup Red solid Dial backup alarm condition exists Yellow solid The unit is in test LAN 1 LAN 2 TD RD Green flashing Activity on the Ethernet port Off No activity on the Ethernet port LAN 1 LAN 2 LNK Green solid 10Base T link is up Yellow solid 100Base T link is up Red Link is down Off Link is administratively down STATUS Slots 1 t...

Страница 19: ...05 DC Rear Panel Layout Rear Panel Interfaces CONSOLE Port The CONSOLE port a DB 9 interface located on the rear panel connects to a computer or modem and provides the following functions Accepts electrical EIA 232 input from a PC or modem for controlling the NetVanta 5305 Operates at rates ranging from 9 6 kbps to 115 2 kbps Acts an input for either VT100 or PC control 1 2 3 REMOVE POWER CORD PRI...

Страница 20: ...05 provides two RJ 48C connectors on the rear panel system controller module for routing data traffic and for local management access See Table A 1 on page 33 for the 10 100Base T Ethernet interface pinouts The 10 100Base T Ethernet ports provide the following Auto sensing Primary data port service Secondary DMZ port service Local management access ...

Страница 21: ...onfiguration for the system using the AOS The NetVanta 5305 System Controller module shown in Figure 4 provides control interfaces for the NetVanta 5305 system including a CONSOLE port DB 9 and two Ethernet interfaces RJ 48 See Table A 2 on page 33 for the CONSOLE connector pinouts and Table A 1 on page 33 for the Ethernet connector pinouts A system controller module is required for all NetVanta 5...

Страница 22: ...assis The T3 Wide Module may be installed in any slot 1 through 6 Table A 3 on page 34 gives the pinouts for this module Figure 5 NetVanta T3 Wide Module Features and Specifications Interface DS3 electrical coax interface Line Rate 44 736 Mbps Line Code Bipolar three zero substitution B3ZS Framing M13 or C bit Connector Dual BNC 1 receive 1 transmit Compliance EMC see Electromagnetic Compatibility...

Страница 23: ...ed in any slot 1 through 6 Table A 4 on page 34 gives the pinouts for this module Figure 6 NetVanta HSSI Wide Module Features and Specifications Interface 50 pin SCSI II female connector Line Rate 0 to 52 Mbps Signal Type Electrically balanced with non return to zero NRZ encoding Compliance EMC see Electromagnetic Compatibility EMC Table on page 6 UL CUL 60950 EN 60950 IEC 60950 AS NZS 60950 Envir...

Страница 24: ...lay Multilink Frame Relay PPP MLPPP HDLC 8xT1 Interfaces Supported Standards AT T TR 62411 AT T TR 54016 ANSI T1 403 Bellcore TR 194 Line Rate 1 544 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Support for Nx64 on all T1 interfaces Line Build Out 0 7 5 15 22 5 dB long 0 to 655 ft short DS0 Assignment Programma...

Страница 25: ...S 60950 RoHS Compliant Telecommunications exemption Environmental Operating Temperature 0 C to 50 C Storage Temperature 20 C to 70 C Relative Humidity Up to 95 percent noncondensing Physical 5 63 inch W x 8 63 inch D T1 E1 Mode Switch The Octal T1 E1 Wide Module is shipped with the T1 E1 mode switch located on the circuit board set to T1 If you require E1 functionality use your thumbnail to slide ...

Страница 26: ...ent electrical shock do not install equipment in a wet location or during a lightning storm The NetVanta 5305 is intended to be installed maintained and serviced by qualified service personnel only and should be installed in a restricted access location as described in UL IEC 60950 1 Ethernet cables are intended for intrabuilding use only Connecting an ADTRAN unit directly to Ethernet cables that ...

Страница 27: ... 1200775L1 can be purchased separately for installation in a standard 23 inch rack Follow these steps to mount the NetVanta 5305 into the equipment rack Instructions for Rack Mounting NetVanta 5305 Step Action 1 Attach the rackmount ears to the NetVanta 5305 chassis 2 To allow proper grounding scrape the paint from the rack around the mounting holes where the NetVanta 5305 will be positioned 3 Pos...

Страница 28: ...be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips For NetVanta modules with outside plant connections ensure that all cables are removed from the module before installing or removing it from the NetVanta chassis Electronic modules can be damaged by static electrical discharge Before handling modules ...

Страница 29: ...th The supplemental earthing conductor shall be connected to the equipment using a number 8 ring terminal and should be fastened to the grounding lug provided on the rear panel of the equipment The ring terminal should be installed using the appropriate crimping tool AMP P N 59250 T EAD Crimping Tool or equivalent The supplementary equipment earthing conductor must not be smaller in size than cros...

Страница 30: ...must be from a reliably grounded 48 VDC SELV source Use only copper conductors minimum 14 AWG when making power connections The ground wire shall be fitted with a number 8 ring terminal and should be fastened to the grounding lug on the back panel of the unit The ring terminal shall be installed using AMP P N 59250 T EAD crimping tool or equivalent Install unit in accordance with the requirements ...

Страница 31: ... s Support Forum The NetVanta VPN Accelerator card is intended to be installed only by qualified service personnel Instructions for Installing the VPN Accelerator Card Step Action 1 Remove power from the unit 2 Use a screwdriver to take the screws out of the system controller module Remove the module 3 Gently slide the accelerator card into the PCI slot as shown The card is keyed to fit into the s...

Страница 32: ...Unit Installation NetVanta 5305 Hardware Installation Guide 32 Copyright 2014 ADTRAN Inc 61200990L1 34P ...

Страница 33: ...mit Positive 2 TX2 Transmit Negative 3 RX1 Receive Positive 4 5 Unused 6 RX2 Receive Negative 7 8 Unused Table A 2 CONSOLE Port DCE Pinouts Pin Name Description 1 DCD Data Carrier Detect output 2 RD Receive Data output 3 TD Transmit Data input 4 DTR Data Terminal Ready input 5 SG Signal Ground 6 DSR Data Set Ready output 7 RTS Request to Send flow control input 8 CTS Clear to Send output 9 RI Ring...

Страница 34: ...tion Description 1 26 HSSI SG Signal Ground 2 27 I HSSI RT Receive Timing 3 28 I HSSI CA DCE Available 4 29 I HSSI RD Receive Data 5 30 I HSSI LC Loopback Circuit C 6 31 I HSSI ST Send Timing 7 32 HSSI SG Signal Ground 8 33 O HSSI TA DTE Available 9 34 O HSSI TT Terminal Timing 10 35 O HSSI LA Loopback Circuit A 11 36 O HSSI SD Send Data 12 37 O HSSI LB Loopback Circuit B 13 38 HSSI SG Signal Grou...

Страница 35: ...DTRAN Inc 35 Table A 5 Octal T1 E1 Wide Module Pinouts for either T1 or E1 Mode Pin Name Description 1 R1 Receive data from the network Ring 1 2 T1 Receive data from the network Tip 1 3 Unused 4 R Transmit data toward the network Ring 5 T Transmit data toward the network Tip 6 8 Unused ...

Страница 36: ...Appendix A NetVanta 5305 Hardware Installation Guide 36 Copyright 2014 ADTRAN Inc 61200990L1 34P ...