Chapter 3
Troubleshooting and
Maintenance
Troubleshooting guidelines and maintenance information are provided in this
chapter.
TROUBLESHOOTING
Power
Condition:
P
OWER
LED
is not illuminated.
•
If locally powered, verify the power cable installation.
Electric LOS
Condition:
E
LECTRIC
L
OS
LED
is illuminated.
1.
Verify that the cable from the network demarcation is connected to the
dual BNC connectors (labeled
E
LECTRICAL
I
NTERFACE
) located on the
back panel of the OCU 45.
2.
If all connections seem intact, check the DS3/STS-1 device on the other
end of the circuit.
Electric Alarm
Condition:
E
LECTRIC
A
LARM
LED
is illuminated.
1.
Line coding violations (LCVs) are being received on the electrical
interface. Check the electrical interface configuration and verify the
current setting is correct.
2.
If the current electrical interface configuration setting is correct, check
the DS3/STS-1 device connected to the OCU 45.
Содержание 1200664L1
Страница 1: ...OCU 45 Part Number 1200664L1 2 3 4 Document Number 61200664L1 1B 61200664L1 1B September 2002 ...
Страница 14: ...14 OCU 45 User Manual 61200664L1 1B List of Figures ...
Страница 15: ...61200664L1 1B OCU 45 User Manual 15 List of Tables Table 2 1 DC Connector Symbol Definitions 22 ...
Страница 16: ...16 OCU 45 User Manual 61200664L1 1B List of Tables ...
Страница 20: ...Chapter 1 General 20 OCU 45 User Manual 61200664L1 1B ...
Страница 30: ...Chapter 3 Troubleshooting and Maintenance 30 OCU 45 User Manual 61200664L1 1B ...
Страница 36: ...Appendix A Connector Pin Definitions 36 OCU 45 User Manual 61200664L1 1B ...
Страница 38: ...61200664L1 1B OCU 45 User Manual 38 Index U UL requirements 23 Unit overview 17 ...