Chapter 2. Installation
22
OCU 45 User Manual
61200664L1-1B
POWERING THE UNIT
The OCU 45 contains a three-position modular terminal lug connector for
supplying DC power to the unit. The modular terminal lug connector allows
the user to easily connect and disconnect DC power when replacing
rackmount units.
To establish DC power, use 12 to 26 AWG wire to connect the modular
connector as follows:
1.
Connect the wire lugs on the modular connector which corresponds to
the positive (+) and negative (-) terminals on the rear panel to a -48V
DC, 0.5A source.
2.
Connect the remaining wire lug to the frame ground.
3.
Once the modular connector is wired, push it firmly into one of the rear
panel
P
OWER
connectors.
Table 2-1 and Figure 2-1 illustrate the DC power connector and give
definitions for the four connector symbols.
Table 2-1. DC Connector Symbol Definitions
Figure 2-1. DC Power Connector
Use copper conductors only.
Symbol
Definition
+
Positive side of DC power source (usually ground)
-
Negative side of DC power source (usually -48V)
Frame Ground
+
Содержание 1200664L1
Страница 1: ...OCU 45 Part Number 1200664L1 2 3 4 Document Number 61200664L1 1B 61200664L1 1B September 2002 ...
Страница 14: ...14 OCU 45 User Manual 61200664L1 1B List of Figures ...
Страница 15: ...61200664L1 1B OCU 45 User Manual 15 List of Tables Table 2 1 DC Connector Symbol Definitions 22 ...
Страница 16: ...16 OCU 45 User Manual 61200664L1 1B List of Tables ...
Страница 20: ...Chapter 1 General 20 OCU 45 User Manual 61200664L1 1B ...
Страница 30: ...Chapter 3 Troubleshooting and Maintenance 30 OCU 45 User Manual 61200664L1 1B ...
Страница 36: ...Appendix A Connector Pin Definitions 36 OCU 45 User Manual 61200664L1 1B ...
Страница 38: ...61200664L1 1B OCU 45 User Manual 38 Index U UL requirements 23 Unit overview 17 ...