CS2-T-2010-09-27
C2-09
-1/8
CS2-T
TEMPERATURE Indicator
DESCRIPTION
CS2-T Temperature Indicator has been designed with high accuracy
measurement, display and communication of Thermocouple or
Pt100
Ω
.
They are also building in 4 Relay outputs, 3 External Control Inputs, 1
Analogue output and 1 RS485 (Modbus RTU Mode) interface with
versatile functions such as control, alarm, re-transmission and
communication for a wide range of machinery and testing equipments
application.
FEATURE
●
Measuring RTD: Pt100
Ω
; Thermocouple: K, J, E, T, R, S, B
●
4 relay can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch / Go energized with Start Delay /
Hysteresis / Energized & De-energized Delay functions, or to be a remote control.
●
Analogue output and RS 485 communication port in option
●
3 external control inputs can be programmed individual to be Relative PV (Tare) / PV Hold / Maximum or
Minimum Hold / DI (remote monitoring) / Reset for Relay Energized Latch….
●
CE Approved & RoHS
ORDERING INFORMATION
CS2
−
T
−
Input
Signal
−
Relay
Output
−
Analogue
Output
−
RS 485
Port
−
Aux.
Powered
CODE
INPUT RANGE
CODE
INPUT RANGE
CODE RELAY O/P CODE ANALOG O/P CODE RS485 PORT
CODE AXU. POWER
P1
Pt100
Ω
-50.00~199.99 °C
K1
Type K 0.0~1200.0
°C
N
None
N
None
N
None
A
AC115/230V
P2
Pt100
Ω
-150.0~800.0 °C
J1
Type J 0.0~750.0
°C
R2
2 Relay
8
RS 485
E1
Type E 0.0~1000.0
°C
R4
4 Relay
V
0(1) ~ 5 V
0 ~ 10 V
T1
Type T 0.0~400.0
°C
ADH
AC 85~264V
DC 100~300V
R1
T/C type R 400~1600
°C
I
0 ~ 10 mA
0(4)~20 mA
ADL
DC 20~56V
S1
T/C type S 400~1600
°C
B1
T/C type B 400~1800
°C
Low cut:
Settable range: -19999~29999 counts
TECHNICAL SPECIFICATION
Digital fine adjust:
pVzro
:
Settable range: -19999~+29999
Input
pVspn
:
Settable range: -19999~+29999
Measuring Range
Input Impedance
Excitation Supply
P1
Pt100
Ω
-50.00~199.99 °C
≥
1M ohm
Reading Stable Function
P2
Pt100
Ω
-150.0~800.0 °C
≥
1M ohm
Sensing Current: 1.6mA
Average:
Average:
K1
Type K 0.0~1200.0 °C
≥
1M ohm
Moving average:
Moving average:
J1
Type J 0.0~750.0 °C
≥
1M ohm
Digital filter:
Digital filter:
E1
Type E 0.0~1000.0 °C
≥
1M ohm
T1
Type T 0.0~400.0 °C
≥
1M ohm
Control Functions(option)
R1
Type R 400~1600 °C
≥
1M ohm
Set-points:
Four set-points
S1
Type S 400~1600 °C
≥
1M ohm
Control relay:
Four relays
B1
Type B 400~1800 °C
≥
1M ohm
Relay 2 & Relay 3: Dual FORM-C, 5A/230Vac, 10A/115V
Relay 1 & Relay 4: Dual FORM-A, 1A/230Vac, 3A/115V
Calibration:
Digital calibration by front key
Relay energized mode:
Energized levels compare with set-points:
A/D converter:
16 bits resolution
Hi / Lo / Go.12 / Go.23 /
Hi.HLd
/
Lo.HLd
; programmable
Accuracy:
Pt100
Ω
:
≤
±
0.1% of FS
±
1C;
DO function: Energized by RS485 command of master.
Thermocouple:
≤
±
0.2% of FS
±
1C;
Banks pre-set:
4 banks pre-set for all relay functions to relative 4
Sampling rate:
15 cycles/sec
difference scaling, and selectable by 3 External
Response time:
≤
100 m-sec.(when the AvG = “1”) in standard
Control Inputs(E.C.I.) Or front key
Cold junction in T/C:
25
±
10
˚
C, error
≤
0.5
˚
C
Energizing functions:
Start delay / Energized & De-energized delay / Hysteresis /
Energized
Latch
Display & Functions
Start band
(Minimum level for Energizing): 0~9999counts
LED:
Numeric:
5 digits, 0.8”(20.0mm)H red high-brightness LED
Start delay time:
0:00.0~9(Minutes):59.9(Second)
Relay output indication:
4 square red LED
Energized delay time:
0.00.0~9(Minutes):59.9(Second)
RS 485 communication:
1 square orange LED
De-energized delay time:
0.00.0~9(Minutes):59.9(Second)
E.C.I. function indication:
3 square green LED
Hysteresis:
0~5000 counts
Max/Mini Hold indication:
2 square orange LED
Display range:
According to sensor range
External Control Inputs(ECI)
Scaling function:
Fix range, please don’t set.
Input mode:
3 ECI points, Contact or open collect input, Level trigger
Fix range, please don’t set.
Functions:
Relative PV (Tare) / PV Hold / Reset for Max or Mini. Hold /
Decimal point:
Fix range, please don’t set.
DI
/ Reset for Relay Energized latch / 4 Banks selection
Over range indication:
ovfl
,
when input is over 20% of input range Hi
Debouncing time:
Settable range 5 ~255 x (8m seconds)
Under range indication:
-ovfl
,
when input is under -20% of input range Lo
Max / Mini recording:
Maximum and Minimum value storage during power on.
Display functions:
PV / Max(Mini) Hold / RS 485 Programmable
Front key functions:
Relative PV / PV Hold / Reset for maxi(mini) hold /
Reset for relay energized latch programmable
CSM-321S
CS2-
V
A
CSM-321S CSM-
CSM-
CS2-T
CSM-321S CSM-
CSM-
CSM-321S
CSM-
CSM-321S
OPTION 2
OPTION 3
OPTION 1
OPTION 4