CS2 SERIES
–OPERATION MANUAL(EN)-A-2017-11-16
28 / 41
D
−
3
aOhs
199(9
199(
9
1
50)0
will be
changed
according to
hIsc
set.
aOhs
(Ao.HS): the High point is relative to
Analogue Output high;
To set the higher display value versus high
output range (as like as 20mA in
A4-20
)
Ex. Output range set to be
A4-20
(4~20mA)
is relative to display 0~199.99. User can set
the
[
aOhs
]
(Ao.HS) to be
15)00.
At
meantime
,
the output signal will be 20mA
when the present value(PV) is 150.00.
Settable range: -19999~29999
Shift
Up
Down
Enter
D
−
4
aOzro
0
0000
0
`
7233
aOzro
(Ao.Zro): Fine Zero Adjustment for
Analog Low Output;
Users can get Fine zero Adjustment for
analogue output by front key. Please
connect standard meter to the terminal of
analogue output for measuring the output
value. To press the front key(up or down
key) to adjust and check the output of meter.
Settable range: -38011~27524
Shift
Up
Down
Enter
D
−
5
aOspn
0
0000
0
3
2767
aOspn
(Ao.SPn): Fine Span Adjustment for
Analog high Output;
Users can get Fine span Adjustment for
analogue output by front key of the meter as
like as
[
aOzro
]
(Ao.Zro).
Settable range: -38011~27524
Shift
Up
Down
Enter
D
−
6
ZSclr
none
none
both
ZSclr
(Z.S.CLr): Clear the Fine Zero / Span
Adjustment for Analog Output
Programmable:
none
(None):
Do not clear
aOzro
(Ao.Zro):
Clear low adjust
aOspn
(Ao.SPn):
Clear high adjust
both
(both):
Clear low & high
adjust
Up
Down
Enter
D
−
7
aOlmt
11)00
11)0
0
1
0)00
aOlmt
(Ao.LMt): Analog Output High Limit
Set Scaling:
[
lOsc
]
:
)00
,
[
hIsc
]
:
19(99
;
Output:
[
aOls
]
:
5)00
(Display value Low),
[
aOhs
]
:
15)00
(Display value High);
[
aOlmt
]
:
8)00
%( of Output Range)
0.00%
100.00%
50.00%
OUTPUT
Ao.LMt: 80.00%
80.00%
SCALE
19(99
[
hIsc
]
)00
[
lOsc
]
10)00
5)00
[
aOls
]
15)00
[
aOhs
]
[
aOlmt
]
Settable range:
0.00~ 110.00% of FS
Shift
Up
Down
Enter
■
RS485 Group
(The group will be hidden, if the relay function is not to be specify )
INDEX
FUNCTION DESCRIPTION
PARAMETERS & SETTING SET
rs485
group
RS485 GROUP INDEX PAGE
In following pages, press
for
1 second to return the RS485
GROUP INDEX PAGE.
E
−
1
adres
1
00
1
2
55
adres
(Address): Device number of the
meter.
Settable range: 1~255
Shift
Up
Down
Enter
E
−
2
baud
9600
9600
38400
baud
(bAUd): Baud rate
Programmable:
1200
/
2400
/
4800
/
9600
/
19200
/
38400
Up
Down
Enter
NEXT PAGE