Chapter I. Safety Notice 

To avoid personal injury and property damage, please read the following 
safety information carefully before testing and using the Driver. Please 
strictly follow the safety measures below: 

¾

 

Please read the User’s Manual carefully, and follow the safety rules 
strictly. 

¾

 

If the input voltage of Q2BYG403MD is higher than 36V, please 
check whether voltage of the Driver terminal is in safe range with a 
multimeter after the power is cut off, and then connect the wire or 
check, or else it may cause electric shock. 

¾

 

Do not connect the wires or insert/remove the terminal when the 
Driver and motor are working, or else it may cause electric shock. 

¾

 

Do not open the shell of the Driver after the power supply is 
connected or when the Driver is running, or else it may cause 
electric shock.   

¾

 

To avoid personal injury or property damage, please ask qualified 
personnel to operate the Driver. 

¾

 

Please follow the technical specification and electrical installation 
standard during the installation. The Driver must be grounded 
properly, and the cross-sectional area of the grounding cable should 
be at least 1.25mm

2

¾

 

Do not put any object in the Driver, or else it may damage the 
Driver. 

¾

 

If the Driver has any failure, please send it to the maintenance 
center. Disassembling the Driver without authorization or improper 
operation may damage the Driver. It will violate the warranty if the 
user opens the Driver shell without authorization. 

¾

 

To dispose of the Driver, please follow local regulations on 
industrial waste disposal to avoid environment pollution. 

 Statement: 

—

 

If this Driver is applied to the machinery and equipment 
directly related to personal safety (nuclear power control, 
medical equipment, truck, train, aircraft, entertainment and 
security equipment), it is required to install protection 
equipment to avoid personal injury. 

—

 

Electronic equipment isn’t permanently reliable. The equipment 
must have sufficient safety measure, in order to protect the 
safety of personnel and equipment in case of Driver failure. The 
customer shall assume the losses due to machine failure or 

Содержание Q2BYG403MD

Страница 1: ...ri iv ve er r U Us se er r s s M Ma an nu ua al l Add F 5 Bldg 27 29 Tianxia IC Industrial Park Yiyuan Rd Nanshan District Shenzhen Tel 0755 26099116 Fax 0755 26722718 616 Postal code 518052 E mail e...

Страница 2: ...ndividual are prohibited This manual doesn t contain any assurance stance or implication in any form Adtech and the employees are not responsible for any direct or indirect data disclosure profits los...

Страница 3: ...cal specification and electrical installation standard during the installation The Driver must be grounded properly and the cross sectional area of the grounding cable should be at least 1 25mm2 Do no...

Страница 4: ...2 2 Features Allow driving 4 6 8 wires two phase step motor Ultra low vibration noise Internal software uses micro segmentation technology which can obtain high segmentation effect in low speed low se...

Страница 5: ...point 18VDC Phase current A 1 2 1 6 2 0 2 4 2 8 3 0 3 6 4 2 Subdivisions 1 2 4 8 16 32 64 128 256 5 10 25 50 100 200 Control mode Pulse direction Type of protection circuit Undervoltage overvoltage a...

Страница 6: ...ow voltage level 0 0 5V high voltage level 4 5V pulse width 1 5us EN EN Enable control signal Used to enable release motor EN is connected to 5V EN is grounded the Driver will cut off the current of t...

Страница 7: ...itter terminal 3 SCI receiver terminal RXD Serial data receiver terminal 4 NC Reserved 5 5V power supply grounding GND Power point 4 Driver status indicator The green LED is power indicator When the p...

Страница 8: ...s differential interface circuit builds in high speed optocoupler the receiving frequency is higher than similar products interface is highly compatible and anti jamming capacity is strong especially...

Страница 9: ...ted to 12V R is 1K when VCC is connected to 24V R is 2K 2 Common cathode wiring when VCC is connected to 5V R is short connected when VCC is connected to 12V R is 1K when VCC is connected to 24V R is...

Страница 10: ...ection If the Driver and motor are connected in different modes the motor running will have significantly different effect Generally the supply voltage of the Driver determines the high speed performa...

Страница 11: ...available Serial mode has large torque at low speed but it can t rotate fast as connected to center tap and the current should be set to 70 of the rated current center tap mode has high speed performa...

Страница 12: ...inaccurate motor positioning instable system and other faults 3 If one power supply is provided to several Drivers it is required to connect them in parallel rather than in chain 4 Do not insert or re...

Страница 13: ...F OFF 4 OFF ON OFF OFF 8 ON ON OFF OFF 16 OFF OFF ON OFF 32 ON OFF ON OFF 64 OFF ON ON OFF 128 ON ON ON OFF 256 OFF OFF OFF ON 5 ON OFF OFF ON 10 OFF ON OFF ON 25 ON ON OFF ON 50 OFF OFF ON ON 100 ON...

Страница 14: ...lected please select the model of appropriate torque according to the load 3 During working it is allowed to change the system transmission ratio through gear box and synchronous belt and thus adjust...

Страница 15: ...put Adjust the pulse signal Subdivision has error Reset the subdivisions Motor load is too high Change the motor or increase the current Position is inaccurate Motor wire bad contact Check and connect...