door/window is closed.

5.  Go through each interior zone individually. Walk in front of any interior motion detectors and listen

for three beeps from the touchpad. The interior zone or description should appear on the display
and clear when you exit the protected area. Wireless motion detectors require a 3 minute delay
between activations.

6.  Test all smoke detectors and follow the manufacturer’s instructions. The detector identification

should appear on the display.

7.  When all protection points have been checked and are intact (e.g., closed), there should be no zone

identification number(s) displayed on the touchpad.

8.  Before exiting test mode, check that there are no zone identification numbers displayed on the

touchpad and that all required sounds were activated and then silenced. If any confirming sounds
or zone identifications were not activated at the correct time, call for service immediately.  Exit test
mode by entering your security code + [1]. Test mode will automatically shut off after 4 hours if not
manually turned off. 

To learn more about testing your system, please visit  

System Testing

.

Other System Information

Time & Date Programming

To View Current Date and Time

 

Enter your [security code] + [#] + [6] [3]. The time/date will remain for about 30 seconds.

To Set Date and Time

Enter your [security code] + [#] + [6] [3]. When the time/date are displayed, press [*].  Enter the 2-digit
hour setting. Press [*]. Enter the 2-minute setting. Press [1] for PM or [2] for AM. Enter the last two digits
of the current year. Enter the 2-digit month setting. Enter the 2-digit day setting. When the cursor is at the
last digit, press [*] or wait 10 seconds to exit. 

Paging Features

Your system may be set up to automatically send alert messages to a pager when certain conditions
occur in your system. An installer can program your system to send a message about arming, disarming,
alarms, and trouble conditions. You can also program the system to send an automatic message in the
event that someone has not arrived home (no disarmament) within a defined period of time.

The pager display format is AAAAAAAAAAAAAAAA – BBB – CCCC

Содержание Safewatch Pro 3000

Страница 1: ...ing Other System Information System Overview Overview The Safewatch Pro 3000 represents the latest in home and business security protection technology providing ADT customers with Burglary emergency a...

Страница 2: ...y Perimeter burglary zones such as protected windows and doors are armed Fire Appears when a fire alarm or fire fault is present Accompanied by a display of the zone in alarm Bat Low battery condition...

Страница 3: ...3 4 Away Mode arms the entire interior and exterior As such this mode is not ideal for those with pets children roaming in and out of interior zones Away mode triggers the exit delay setting the away...

Страница 4: ...ir at the same time Function Signal to Customer Care Sound Activated Silent Alarm Silent alarm No audible alarm to indicate silent alarm has been activated but message sent to Customer Care Audible Al...

Страница 5: ...Can only arm the system cannot disarm or do other functions 4 Guest Typically assigned to a babysitter or a cleaner a guest can arm the system in the assigned partitions but cannot disarm the system u...

Страница 6: ...assign a wireless button device keyfob to this user For the zone number enter the number assigned to a button on the keyfob that will be used for arming disarming by this user Pager On Off Mast Prog...

Страница 7: ...ediately Exit test mode by entering your security code 1 Test mode will automatically shut off after 4 hours if not manually turned off To learn more about testing your system please visit System Test...

Страница 8: ...Paging which will alert a parent via their pager and a secret code if their child did not disarm the system at the scheduled time Scheduling To Create a Schedule Enter the Master code 6 4 Enter 2 digi...

Страница 9: ...t number type of event by code zone user number partition where the event occurred time and date of event 3 Pres to display previous events press to display future events 4 To exit the Event Log press...

Страница 10: ...function Please see the manufacturer s manual for a detailed explanation of this feature Accessing Other Partitions and Multi Partition Arming For information about accessing other partitions please...

Страница 11: ...red and the countdown to arming has begun Entry Delay beeps indicate that you ve entered the building and the countdown to an alarm has begun So disarm the system as soon as you get in Trouble beeps t...

Страница 12: ...hether open or bypassed low battery supervisory AC power or backup battery failures To get a Short System Status press is labeled Status The system sounds beeps according to the current arming level O...

Страница 13: ...hpads in your system emit alarm sounds whenever an alarm occurs either by a sensor or panic button activation Each type of alarm sounds and reacts differently when activated as described in the follow...

Отзывы: