ADS FlowShark HV O&M Manual
25
Technical Specifications
The following tables include the technical specifications for the components
comprising the FlowShark HV and the CE guidelines. When applicable, certain
specifications may reflect using the equipment under optimal operational and
environmental conditions. Individual specifications also may include details
concerning possible external influences or conditions that may affect the velocity data
obtained.
Control Unit
The following table contains the specifications for the control unit.
Enclosure
Lacquered aluminum casing with shoulder strap
Dimensions
4.45 inches (113 mm) high x 6.81 inches (173 mm) wide x 8.66
inches (220 mm) deep
Protection
Rating
IP65 (NEMA 4)
Weight
8.27 pounds
Display
LCD; 4 rows x 20 characters
Operation
6-key
Range
0 to 9.8 feet per second (0 to 3 meters per second)
Accuracy
1% of the actual velocity measured
or
±0.03 feet per second
(±0.01 mps), whichever is greater
Operating
Temperature
32° to 122° F (0° to 50° C)
Storage
Temperature
23° to 140° F (-5° to 60° C)
Power Supply
12-volt/ 2 Ah rechargeable lead battery
Battery Life
4 to 6 hours of cumulative use
Battery
Charger
Primary: 115/230 V AC
Secondary: 12 V/ 500 mA
Connectors
•
Sensor
•
Charger