background image

Industrial PCs IPC1300

 

 

© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen

 

9

 

 

2

 

S

AFETY INFORMATION

 

The device is electrically charged and contains highly sensitive components. Permissible 
modification by the user is limited to installing add-on cards. The manufacturer or a service 
provider authorized by the manufacturer should be consulted if any other modifications are 

to be carried out. Whenever such modifications are carried out the device must first be 
switched off and the power cable must be disconnected. The appropriate measures should 

be implemented to avoid electrostatic shock to the components upon contact. Opening of 
the device by a non-authorized person could result in hazards to the user and renders any 
warranty claims invalid. 

G

ENERAL NOTICE

 

The manual should be read by all users and should be kept readily accessible at all 
times. 

 

Mounting, startup and operation should only be carried out by trained personnel. 

 

All persons using the device should observe the safety information and the 
manual. 

 

The rules and regulations pertaining to accident prevention should be observed in 
the place of device installation. 

 

The manual contains the most important information required for safe operation of 
the device. 

 

Proper storage, transport, installation and startup are required to ensure correct 
and safe device operation. 

 

Caution:  

The device should be switched off prior to connecting any cables (power supply, 

peripherals) to prevent damage to the device. 

2.1

 

P

LACE OF INSTALLATION

 

The control system is intended for installation in the control cabinet. The specified ambient 

conditions should always be adhered to. Use in non-specified environments (e.g. on boats, 
in explosive hazard areas or at extreme altitudes) is prohibited. 
 

 

Caution:  

In order to avoid formation of condensation, the device should only be switched on once 

it has acclimated to the room temperature. The same applies if the device has been 

exposed to extreme variations in temperature.  
Preventing overheating during operation: The device should not be exposed to direct 

sunlight or other sources of light. 

Pos : 11 /D atent ec hni k/Betri ebs hi nweis e/ Sc häden durch uns achg emäß en G ebrauc h/Schäden durc h unsac hgemäß en G ebr auch @ 0\ mod_1158827867958_681. doc @  728 @    

2.2

 

D

AMAGE CAUSED BY IMPROPER USE

 

This device must immediately be shut down and protected from any accidental 

commissioning if the operating system shows any obvious damage caused by, for example, 
improper operating or storage conditions, or by improper use or handling.  

 

 

Pos : 12 /D atent ec hni k/Betri ebs hi nweis e/ Gewährleist ung / R eparatur/ G ewährleist ung / R epar at ur @ 0\ mod_1158828054427_681. doc @ 730 @  

 

2.3

 

W

ARRANTY 

/

 REPAIR

 

During the warranty period any repair must only be carried out by the manufacturer or by 

a person authorised by the manufacturer.  

 

Pos : 13 /D atent ec hni k/Mont age/Mont agemöglichkeiten/M ontag emöglichkeit  f ür I PC 1100 @  0\ mod_1158830335724_681.doc @ 742 @  

 

Содержание IPC1300

Страница 1: ...User Manual Industrial PCs IPC1300 Version 1 0...

Страница 2: ...Industrial PCs IPC1300 2 ads tec GmbH Raiffeisenstr 14 70771 Leinfelden Echterdingen Product Portfolio Copyright ads tec GmbH Raiffeisenstr 14 D 70771 Leinfelden Echterdingen Germany...

Страница 3: ...STRATION IPC1300 24V DC 11 3 3 DEVICE MOUNTING ILLUSTRATION IPC1300 230V DC 12 3 4 MOUNTING PROCEDURE 13 4 ADD ON CARD INSTALLATION 14 4 1 PRE INSTALLATION NOTES 14 4 2 NOTES ON CONFIGURING THE ADD ON...

Страница 4: ...felden Echterdingen 7 1 HARD DRIVE COMPACTFLASH IDE INTERFACE 23 8 SOFTWARE DRIVER INSTALLATION 24 8 1 INSTALLING THE OPERATING SYSTEM 24 9 TECHNICAL DETAILS 25 9 1 COMPUTER TECHNICAL DATA 25 10 SERVI...

Страница 5: ...ei ne Hinweise R elevante Dokumentationen zum Ger t Rel evante D okumentati onen f r IPC PLC ITC 0 mod_1158742442637_681 doc 686 Echterdingen S chterdingen 45894 0 45894 990 des large enterprises and...

Страница 6: ...DATA FIGURES AND MODIFICATIONS All texts data and figures are non binding We reserve the right of modification in accordance with technological progress At that point in time when the products leave o...

Страница 7: ...1187896232_681 doc 6146 1 6 AMBIENT CONDITIONS The device can be operated in the following ambient conditions The device warranty will be rendered invalid upon noncompliance with these specifications...

Страница 8: ...e legal requirements in force on electromagnetic compatibility all components and cables used for unit connection must also be compliant with said regulations It is therefore necessary to employ BUS a...

Страница 9: ...n The device should be switched off prior to connecting any cables power supply peripherals to prevent damage to the device 2 1 PLACE OF INSTALLATION The control system is intended for installation in...

Страница 10: ...o prevent heat accumulation should be implemented if the device is installed in a console casing or similar enclosing structure The maximum permissible ambient temperature should not be exceeded The f...

Страница 11: ...Industrial PCs IPC1300 ads tec GmbH Raiffeisenstr 14 70771 Leinfelden Echterdingen 11 3 2 DEVICE MOUNTING ILLUSTRATION IPC1300 24V DC...

Страница 12: ...USTRATION IPC1300 230V DC Pos 15 D atentechni k Montage Rei henfolge der Montage Rei henfolge der Montage f r IPC 1100 PLC 300 ITC Serie 0 mod_1158842002183_6 doc 303 Pos 15 D atentechni k Montage Rei...

Страница 13: ...hten the screws and insert the rest of the screws Note The device is connected to the power supply using a lead out terminal with a screw connection A ground connection does not have to be made becaus...

Страница 14: ...shock to the components upon contact Pos 17 D atentechni k Steckkar tenei nbau Hi nweis zur Konfiguration der Steckkarten Hinweise zur Konfiguration der Steckkarte 0 mod_1158844984298_681 doc 779 4 2...

Страница 15: ...e the cover with force Reduce electrostatic charge by implementing the appropriate measures see above remove the add on card from the packaging place it in the slot and bolt it to the card mount Each...

Страница 16: ...the matching drivers have to be installed to be able to use the interfaces Pos 20 D atentechni k Inbetri ebnahme Kabelmontage Kabelmontage f r OPC Seri e IPC 5100 5300 5500 1100 0 mod_1158848147709_68...

Страница 17: ...16042480_681 doc 5557 Pos 25 D atentechni k Bedienung Status Anzeig en SYS LED SYS LED f r OPC CPC PLC OTC ITC VMT Monitore Seri e IPC 5100 5300 5500 1100 1 mod_1204714132162_681 doc 3406 5 5 STATUS I...

Страница 18: ...USB Anschluss U SB Anschl uss f r OPC IPC C PC PLC OTC ITC VMT MSD Seri e 0 mod_1158923823971_681 doc 865 PIN NUMMER 1 2 3 Ind ads tec GmbH Raiffeisenstr RATION IRQ ADDRESS 4 3F8h PLY e is provided v...

Страница 19: ...rface complies with the USB 2 0 standard PIN NUMBER SIGNAL NAME 1 VDC 2 D 3 D 4 GND Note The USB interfaces may be locked using the Lock USB software tool You ll find this software and the documentati...

Страница 20: ...NUMBER SIGNAL NAME 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 NC Pos 31 D atentechni k Schnittstell en Seriell e Schnittstell e C OM RS232 Serielle Schnittstell e C OM RS232 f r OPC IPC C PC PLC OTC ITC VM...

Страница 21: ...occur if not observed Pos 33 D atentechni k Schnittstell en Temparatur ber wachung Tempar atur ber wachung f r OPC IPC 5100 5300 5500 1100 CPC PLC OTC ITC Serie 0 mod_1158930009922_681 doc 887 6 8 TEM...

Страница 22: ...video s ect a digital display to the device It is also pos suitable DVI VGA adapter ce is a Single Link Interface The DVI Interface w m mode SIGNAL NAME TMDS Data2 TMDS Data2 TMDS Data2 4 Shield N C...

Страница 23: ...mplements a 2 5 Festplatte mind 60 GB SATA The hard drive is formatted using the NTFS file system Windows XP default Note Recommendations for choosing the storage medium for a basic installation Compa...

Страница 24: ...e existing interfaces An external keyboard is required for installation 8 1 INSTALLING THE OPERATING SYSTEM If the device is not equipped with an integrated drive installing the operating system can o...

Страница 25: ...t Intel GMA X4500 in GS45 Chipset Graphic memory max 256 MB shared Mass Storage 2 5 Automotive Hard Disk min 60GB SATA oder 2 5 SSD Interfaces COM 1 RS232 COM 2 RS232 1 x DVI I 6 x USB 2 0 Network 4 x...

Страница 26: ...spect to specific configurations and software installations arise it can only be resolved by the system manufacturer For devices not directly purchased from ads tec we cannot be responsible for the su...

Отзывы: