4. 

INSTALLATION

 (Please also refer to the following drawing) 

4.1  Fix the metallic window plate on the rear panel of your computer case. 

4.2  Plug the connector of the enclosed “Y” type power cord into the 

window plate. 

4.3  Plug the connector of the power cord from the UPS with the 

matching connector of “Y” power cord. 

4.4  The “Y” power cord has 2 outlets for your computer and monitor. To 

ensure that your computer will be protected during a utility failure, the 
outlets of UPS must be connected with your computer and monitor, 
and apply the original power cord of your computer as the input cord of 
the UPS. When the connection is completed. The UPS can be turned 
on by one touch at the control button on the front panel. 

 

 

 

 

 

 

 

 

 

 

 

 

    

    

    

  

5. 

 

TESTING 

YOUR 

UPS

5.1

 

Before test, please have the UPS charged for one day or the time 
mentioned in the spec. sheet. 

(Do not have to turn on your computer, just keep the city power 
connected to the UPS and turn on your UPS – green LED will be on.)

 

5.2

 

In normal mode of UPS, turn on your computer, push the UPS button 
on the front panel for self-test.  If it is OK, green LED will be on. 
While if it is over loaded, the UPS will alarm.    Or if the battery level is 
low, it will emit quick beep for several seconds and stay in normal 
mode for recharging. 

Please also refer to the, “LED/Alarm Indication” in item 7.5. 

5.3  Push the button for 4sec, and check if the UPS can be turned-off 

manually. 

5.4  Push the button again to turn on the UPS, then UPS will enter 

stand-by status, and finish the test. 

 

6. 

ERROR MESSAGE OF THE TEST 

6.1  During the test, if the UPS emits a quick beep, it means the battery 

level is low. Please leave the UPS in normal mode for at least 10 
hours, and the batteries will be fully charged.

 

6.2  If the UPS emits a continuous beep during the test, it may be in an 

overload situation. The over load may result in an unexpectedly short 
runtime during a blackout. Please turn off the computer and check if 
any equipment can be removed from the UPS. 

 

6.3  If the UPS emits a continuous urgent beep for 12 seconds after test, 

it means that the batteries are no good and may need replacement.

 

6.4  Since the UPS is made with frequency auto-select function.  Either 

50Hz or 60Hz of your city power, the UPS will detect it, and apply the 
same frequency in operation.  However, if the frequency of city 
power is abnormal, outside the range 47 – 65Hz, the UPS will switch 
to backup mode for protecting your computer. (Even the city power 
voltage is O.K.)   

 

ORIGINAL POWER CORD   

OF COMPUTER 

 METALLIC 

 WINDOW 

 

 

PLATE

SWITCHING 

SUP

POWER 

IEC FEMALE 

PLY

IEC FEMALE 

TO MONITOR   

IF REQUIRED 

DB9 

IEC MALE

Micro PC series 

Micro PC series 

 

3                                                                                                                                                                            4 

Содержание micro PC Series

Страница 1: ... 90 LED ALARMINDICATION Normal In charge GRN LED No Beep Backup AbnormalInputVoltage RED LED Flashing 2 Beeps 4 sec Power Saving When No Load RED LED Flashing 1 Beep 4 sec Auto off in 30 sec Low Battery RED LED Flashing 4 Beeps sec Battery Replacement RED LED Flashing 8 Beeps sec Over Load Fault RED LED Flashing Continuous Beep AbnormalInputFrequency Backup RED LED Flashing No Beep OPERATION TEMP ...

Страница 2: ...puter interface port is diagramed above for your reference Use Pin4 as the common of Pin2 and Pin5 Pin2 and Pin4 will become close loop from open when the utility is fail Pin5 and Pin4 will become close loop from open when the battery level is low The UPS will shut down when the high level from RS 232 sustained for 3 seconds is applied between Pin6 and Pin7 8 BUTTON FUNCTION ON FRONT PANEL button ...

Страница 3: ... for a Pentium III including 15 LCD monitor is about 10 minutes with Micro PC 300 and about 30 minutes with Micro PC 600 2 MAIN FEATURE Microprocessor based design Green power design with auto on off function Suitable for 5 1 4 disk size Protection for overload short circuit Easy installation 3 CAUTION The UPS is suitable for personal computer workstation only and is to be installed inside a compu...

Страница 4: ... seconds and stay in normal mode for recharging Please also refer to the LED Alarm Indication in item 7 5 5 3 Push the button for 4sec and check if the UPS can be turned off manually 5 4 Push the button again to turn on the UPS then UPS will enter stand by status and finish the test 6 ERROR MESSAGE OF THE TEST 6 1 During the test if the UPS emits a quick beep it means the battery level is low Plea...

Отзывы: