5.4.2
Editing of the value of operational parameters
By
accessing
the
configuration
mode
from
the
parameter
selection
menu,
the
instrument
shows
the
parameter's
value
or
code
on
the
main
display.
The
display
flashes
to
indicate
that
the
instrument
is
ready
to
accept
the
edited
parameter’s
value.
Press
key
to
increase
the
value
of
the
selected
parameter
(once
the
maximum
value
is
reached,
the
system
returns
automatically
to
0).
If
the
data
shown
is
a
weight
(e.g.
a
relay
threshold),
the
increase
takes
place
according
to
the
configured
sensitivity.
By
keeping
key
pressed,
the
increase
gradient
is
automatically
increased
up
to
maximum
128
times
the
basic
increase
value.
Press
key
to
decrease
the
value
of
the
selected
parameter
(once
zero
is
reached,
the
system
returns
automatically
to
the
maximum
value).
If
the
data
shown
is
a
weight
(e.g.
a
relay
threshold),
the
decrease
takes
place
according
to
the
configured
sensitivity.
By
keeping
key
pressed,
the
decrease
gradient
is
automatically
increased
up
to
maximum
128
times
the
basic
decrease
value.
Press
to
cancel
the
configuration
request
and
return
to
the
selection
menu
of
the
next
parameter.
Press
key
to
confirm
the
change.
The
instrument
checks
if
the
set
value
is
acceptable
and
displays
the
following
message
for
2
seconds:
D O N E
and
then
it
automatically
returns
to
the
parameter’s
selection
menu.