Admag SE100DJ/EJ Скачать руководство пользователя страница 19

IM 1E10D0-01E

5-1

5. OUTLINE

5.

OUTLINE

STANDARD SPECIFICATIONS

Protection: IP67, NEMA 4X, JIS C0920 water tight type

Size in mm (inch):

15 (0.5), 25 (1), 40 (1.5), 50 (2), 80 (3), 100 (4),
150 (6), 200 (8), 250 (10), 300 (12), 350 (14), 400 (16)

Coating:

Terminal Box:

Polyurethane corrosion-resistant coating,
Deep sea moss green (Munsell 0.6Y3.1/2.0)

• Terminal box is coated for all type

Body:

Polyurethane corrosion-resistant coating,
Deep sea moss green (Munsell 0.6Y3.1/2.0)

• All sizes of carbon steel flange type
• 150 and 200 mm of wafer type

No coating

• 15 to 100mm of stainless steel flange type
• 15 to 100mm of wafer type

Flow Tube Material:

Size 15 to 100mm (0.5 to 4 in.)

Housing : Stainless steel

(15mm:SCS11, 25 to100mm:SUS304)

Mini-flange for wafer conn. : Stainless steel

(SUS430)

Flange : Carbon steel (SS400) or stainless steel

(SUS304)

Pipe :

Stainless steel
(15 to 25mm:SCS13, 40 to 100mm:
SUS304)

Terminal box : Aluminum alloy

Size 150 to 400mm (6 to 16 in.)

Housing  : Carbon steel (SS400)
Mini-flange for wafer conn. : Carbon steel

(SS400)

Flange : Carbon steel (SS400) or stainless steel

(SUS304)

Pipe :

Stainless steel (SUS304)

Terminal box : Aluminum alloy

Wetted Part Material :

Lining :

Fluorocarbon PFA

Elecctrode : Stainless steel (SUS316L), Hastelloy

C (equivalent to Hastelloy C-276)
Titanium, Tantalum, Platinum-Iridium,
Tungsten Carbide.

Earth Ring : • Size 15 to 200mm

   Stainless steel (SUS316), Hastelloy C
   (equivalent to Hastelloy C-276),
   Titanium, PFA Earth
   electrode*.

*Earth Electrode: Tantalum,
  Platinum-Iridium.

• 

 Size 250, 300mm

   Stainless steel(SUS316), Hastelloy C
   (equivalent to Hastelloy C-276),
   Titanium

• 

 Size 350, 400mm

   Stainless steel (SUS316)

Note : Hastelloy is a registered trademark  of Haynes
International Inc.

Gasket :

•  VALQUA#4010 ; Fluoro rubber, viton (between

flow tube body and earth ring; for optional
code/FRG)

•  Non-asbestos joint sheet sheathed with fluoro

resin PTFE (between earth ring and process
flange; for optional code /BSF)

* Other gaskets between flow tube and earth ring;

•  VALQUA#4010(Mixing#RCD970) ; Alkari

resistance gasket for PVC piping(Fluoro
rubber)

•  VALQUA#4010(Mixing#RCD470) ; Acid

resistance gasket for PVC piping(Fluoro
rubber)

Contact YOKOGAWA office. (Refer to TI 1E6A0-06E)

Electrode Construction: External insertion type.

Electrical Connection:

ANSI 1/2NPT female, DIN Pg13.5 female,
ISO M20 X 1.5 female, JIS G1/2 female.

STANDARD pERFORMANCE

Accuracy :

Size in mm 

(inch)

Span in m/s 

(ft/s)

Accuracy

15 to 400

(0.5 to 16)

T01.EPS

0.25% of span
(at indications below 50% of span)

0.5% of rate
(at indications 50% of span or more)

0.5% of span

0.3 to 1

(1 to 3)

1 to 10

(3 to 33)

Repeatability: 0.1% of flowrate(minimum 1mm/s)

Maximum Power Consumption: 11W (incl.converter)

Insulation Resistance:

• 100MW between excitation terminal(EX1) and

signal terminals(A, B and C) at 500V DC.

• 100MW between common terminal(C) and signal

terminals(A and B) at 500V DC.

• 100MW between signal terminal (A) and signal

terminal(B) at 500V DC.

Withstand Voltage:

• 1000V AC between excitation terminals (EX1 and

EX2) and ground terminal(G) for 1 minute.

• 500V AC between signal terminals(A and B) and

ground terminal(G) for 1 minute.(for /KF2, /FF1)

• 2000V AC between signal terminals(A and B) and

excitation terminals(EX1 and EX2) for 1 minute.
(for /KF2, /FF1)

CAUTION

When performing the Voltage Breakdown Test,
Insulation Resistance Test or any unpowered
electrical test, wait 10 seconds after the power
supply is turned off before removing the hous-
ing cover. Be sure to remove the Short Bar at
terminal “G”. After testing, return the Short Bar
to its correct position. Screw tightening torque
should be 1.18N-m(0.88ft-lb)or more, because
the G-terminal is thought as a protective
grounding and should conform to the Safety
Requirements.

Содержание SE100DJ/EJ

Страница 1: ...User s Manual Y okogawa Electric Corporation Models SE100DJ EJ SE200DJ EJ and SE300DJ EJ Magnetic Flow Tube IM 1E10D0 01E IM 1E10D0 01E 8th Edition...

Страница 2: ...recautions 3 3 3 2 2 Flow Tube Piping 3 4 3 3 Mounting 3 4 3 3 1 Nominal Diameter 15mm 0 5 to 40mm 1 5 Wafer Type 3 4 3 3 2 Nominal Diameter 50 mm 2 to 200 mm 8 Wafer Type 3 6 3 3 3 Nominal Diameter 1...

Страница 3: ...recautions The following general safety precautions must be observed during all phases of operation service and repair of this instrument Failure to comply with these precautions or with specific WARN...

Страница 4: ...self because the surface of body and case reach a high temperature When removing the instrument from hazardous processes avoid contact with the fluid and the interior of the flow tube All installation...

Страница 5: ...e Precautions In case the instrument is expected to be stored over a long term please give attention to the followings The instrument should be stored in its original packing condition The storage loc...

Страница 6: ...ucer pipe Expander pipe Tee 90 degrees bent Various types of valves 5 D or more 2 D or more 2 D or more 2 D or more 10 D or more 10 D or more 5 D or more 5 D or more Do not care to 0 D Do not care to...

Страница 7: ...uid is always filled in the pipes The Vertical Mounting is effective for fluids that is easily separate or slurry settles within pipes In this case please flow a fluid from bottom to up GOOD GOOD BAD...

Страница 8: ...prevent persons from injuring when it is handled 3 2 1 General Precautions 1 Precaution for Carrying The Magnetic Flow Tube is packed tightly When it is unpacked please give attention to prevent dama...

Страница 9: ...elding scrap or wood chips may exist Please remove them by flushing piping before mounting the flow tube Slant Mis alignment F030202 EPS Figure 3 2 2 Slant and Mis alignment of Flow Tube Piping 3 3 Mo...

Страница 10: ...pieces Please use appropriate bolts and nuts according to Process connection Horizontal Mounting Vertical Mounting F030301 2 EPS Figure 3 3 1 Mounting Procedure Size 15 mm 0 5 to 40 mm 1 5 Table 3 3 1...

Страница 11: ...es two for each and lower adjacent holes of both flanges Refer to Figure 3 3 2 Please give attention to the nominal size and flange ratings of the centering devices Refer to Table 3 3 5 3 Positioning...

Страница 12: ...has equal elasticity T030303 EPS Table 3 3 4 Tightening Torque Values for PVC Piping in N m kgf cm in lbf Size mm inch JIS 10K JIS 20K ANSI 150 ANSI 300 DIN PN10 50 2 80 3 100 4 150 6 200 8 8 2 84 73...

Страница 13: ...termi nal box In case the measuring fluid flows against the arrow direction please refer to the section Reversing Flow Direction in the Instruc tion Manual of SE14 Magnetic Flow Converter Flange Flow...

Страница 14: ...363 531 65 0 93 0 663 949 575 823 125 1 151 5 1280 1550 1112 1347 153 5 180 9 1570 1850 1365 1608 94 0 125 0 959 1275 832 1106 135 9 164 3 1390 1680 1208 1460 154 5 199 5 1580 2040 1373 1773 151 5 192...

Страница 15: ...er if it is too short Please replace the short cable with the cable which is appropriate length wholly The all cable ends are to be provided with round crimp on terminal The signal cables must be rout...

Страница 16: ...cables JIS C3401 or Polyvinyl chloride insulated and sheathed portable power cables JIS C3312 or equivalents Outer Diameter 6 5 to 12mm in diameter 10 5 to 11 5 mm for waterproof gland ECG ECU Nominal...

Страница 17: ...terminal C and terminal A B Between terminal A and terminal B Between terminal EX1 and ground Between terminal EX2 and ground All insulation measurements must be performed with a 500V megger Insulati...

Страница 18: ...converter Please refer to Instruction Manual of SE14 magnetic flow converter IMPORTANT Be sure to disconnect the cables at the terminals of the flow tube when checking 1 Excitation Coil Check Check th...

Страница 19: ...and earth ring for optional code FRG Non asbestos joint sheet sheathed with fluoro resin PTFE between earth ring and process flange for optional code BSF Other gaskets between flow tube and earth rin...

Страница 20: ...00 150 200 250 300 350 400 0 1909 0 5302 1 3572 2 1206 5 429 8 483 19 086 33 93 53 02 76 35 103 91 135 72 Size 6 361 17 671 45 23 70 68 180 95 282 74 636 1 1 130 9 1 767 1 2 544 6 3 463 4 523 SI Units...

Страница 21: ...for 80 to 150mm because of same mating dimensions Note 2 Only ANSI1 2NPT electrical connection is available for FM or CSA explosion proof type JIS G1 2 electrical connection is not available for any...

Страница 22: ...ing Treatment Degreased cleansing treatment Packing with desiccant Coating is changed to three layer coating Urethane coating on two layer Epoxy coating X2 K5 GOS Calibration Certificate for GOST Only...

Страница 23: ...8 1 H H1 L 1 111 4 4 48 1 9 80 5 3 2 Lining Outside diameter Height Fluorocarbon PFA 86 3 4 D D D Ground Terminal SD2d eps 1 When no earth ring is selected the face to face length is shorter by approx...

Страница 24: ...11 5 11 5 11 3 13 0 10 5 6 4 6 4 6 1 6 2 5 4 5 5 4 9 4 9 0 7 0 7 1 1 2 0 2 4 3 1 Flange outside dia Dia of holes Number of holes Thickness Except P T Earth ring D C 10 1 Lining Fluorocarbon PFA Fluor...

Страница 25: ...ole pitch 22 5 22 5 22 5 22 5 22 5 22 5 22 5 22 5 22 5 45 45 45 150mm 6in 200mm 8in Flange Type Unit mm Approx inch Ground Terminal 80 5 3 2 48 1 9 86 3 4 111 4 4 20 5 0 8 68 2 7 H1 H2 L 1 T 2 H C D N...

Страница 26: ...10 16 400 16 22 0 9 26 1 431 8 17 450 8 18 25 4 1 31 7 1 2 414 16 3 23 0 9 40 1 6 59 2 3 34 1 3 36 1 4 34 1 3 34 1 3 400 15 7 25 1 44 1 7 430 16 9 27 1 1 16 16 10 12 12 16 12 96 104 87 88 87 87 91 SE3...

Страница 27: ...nstallation WARNING All wiring shall comply with local installation requirements and local electrical code In hazadous locations the cable entry devices shall be of a certified flameproof type suitabl...

Страница 28: ...ure 70 C 85 C 120 C 150 C Minimum Process Temperature 40 C 40 C 40 C 40 C Enclosure NEMA 4X Ambient Temperature 20 to 60 C Maximum Working Pressure 4MPa SE115E to SE205E 2MPa SE208E to SE220E Flange r...

Страница 29: ...of Certification 6 4 SAA 1 Technical Data SA Certificate No AUS Ex 3764X Type of Protection Ex d m ia II C T6 T3 Enclosure Type IP67 Excitation Circuit 41Vmax 6 6 25Hz Electrode Circuit Um 250V ac dc...

Страница 30: ...02D E are not attached CE mark of PED because they do not come under CE marking of PED 2 Installation WARNING Please tighten the bolts for piping joint according to the prescribed torque values Please...