![Admag SE100DJ/EJ Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/admag/se100dj-ej/se100dj-ej_user-manual_2852899010.webp)
IM 1E10D0-01E
3-5
3. INSTALLATION
(3) Positioning Flow Tube
Please pass two through-bolts to adjacent holes of both
flanges and mount the Flow Tube, and pass other
through-bolts to other holes. (Refer to Figure 3.3.1) In
case stud type of through-bolts are used, position them
coming in contact centering devices with thread of
bolts.
(4) Tightening Nuts
Please tighten the bolts according to Torque Values in
Table 3.3.1. In case of PVC piping, please select
optional code /FRG, use rubber gasket and tighten with
the torque value in Table 3.3.2.
CAUTION
As the lining material is Fluorocarbon PFA, it is
possible that nuts may loose by its character as
time passes. Please tighten the nuts regularly.
Please be sure to tighten the bolts following
prescribed torque values. Please tighten the
flange bolts diagonally with the same torque
values, step by step up to the prescribed torque
value.
Through-Bolt
and nut
Flange
Mini-Flange
Gasket
F030301-1.EPS
Centering Device
2-pieces
Please use appropriate bolts and
nuts according to Process connection.
Horizontal Mounting
Vertical Mounting
F030301-2.EPS
Figure 3.3.1
Mounting Procedure (Size: 15 mm(0.5") to 40
mm(1.5")
Table 3.3.1
Tightening Torque Values for Metal Piping in N-m{kgf-cm}[in-lbf]
Size mm(inch)
JIS 10K
JIS 20K
ANSI 150
ANSI 300
DIN PN40
15(0.5)
25(1)
40(1.5)
4.5 - 6.5
{46 - 66}
[40 - 58]
14.5 - 19.0
{148 - 194}
[128 - 168]
26.0 - 31.0
{265 - 316}
[230 - 274]
4.5 - 6.5
{46 - 66}
[40 - 58]
14.5 - 19.0
{148 - 194}
[128 - 168]
26.0 - 31.0
{265 - 316}
[230 - 274]
5.0 - 7.0
{51 - 71}
[44 - 62]
12.0 - 15.0
{122 - 153}
[106 - 133]
22.0 - 25.0
{224 - 255}
[195 - 221]
5.0 - 7.0
{51 - 71}
[44 - 62]
14.5 - 19.0
{148 - 194}
[128 - 168]
30.0 - 37.0
{311 - 377}
[270 - 327]
5.0 - 6.5
{51 - 66}
[44 - 58]
12.5 - 14.0
{128 - 143}
[111 - 124]
28.5 - 31.0
{291 - 316}
[252 - 274]
*Please use compressed non-asbestos fiber gasket, PTFE gasket or the gasket which has equal elasticity.
T030301.EPS
Table 3.3.2
Tightening Torque Values for PVC Piping in N-m{kgf-cm}[in-lbf]
Size mm(inch)
JIS 10K
JIS 20K
ANSI 150
ANSI 300
DIN PN40
15(0.5)
25(1)
40(1.5)
1.3
{13}
[12]
3.5
{36}
[31]
5.7
{58}
[50]
1.3
{13}
[12]
2.8
{29}
[25]
4.6
{47}
[41]
1.3
{13}
[12]
2.7
{28}
[24]
5.7
{58}
[50]
*Please select optional code /FRG and use rubber gasket or others which has equal elasticity.
T030302.EPS