![ADLINK Technology PCI-9524 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/adlink-technology/pci-9524/pci-9524_user-manual_2852817026.webp)
6
Introduction
PCI-9524
ADLINK Technology Inc.
User’s Manual
Copyright 2008
Table 1-5: Settling Error: (Typical, 25°C)
X
Time-base source: Internal 40 MHz
X
Trigger mode: post-trigger
X
Offset error:
Z
Before calibration: ±0.5mV typical
Z
After calibration: ±0.001mV typical (auto-zero disabled),
< ±0.001mV typical (auto-zero enabled)
X
Transfer Linearity:
Z
Better than: ±0.0035% over full-scale input range
X
Gain error:
Z
Before calibration: ±1% typical
Z
After calibration: ±0.5% typical
Analog Input (AI) for General Purpose
X
Number of channels: (programmable)
Z
4 differential input (DI)
X
A/D converter:
Z
ADS1255
X
Maximum sampling rate:
Z
30,000 samples/s (single channel)
Z
1.638 samples/s (multiplexed/scanning)
X
Resolution:
Z
24-bit
X
Input coupling: DC
Input Range
Condition
Settling Error
±200mV
Scanning 200mV step
max 0.01%