Motion Control Theory
127
PCI-8254 / PCI-8258
4.6 Jog Move
Jog operation is commonly available at control panel of machine.
Its main function is to manually control the movement of motion
axis or function together with mechanical switch with digital input
to use DI signal as the jog movement startup signal. You may use
switch on control panel to operate jog movement by setting up
relevant parameters instead of coding control program.
There are two jog movement modes:
1.
Continuous mode:
This is similar to velocity movement
with given maximum speed and acceleration profile.
When JOG-ON signal (*) produces rising edge event
trigger then the specified control axis starts velocity
movement. When JOG-ON signal (*) produces falling
edge event trigger then the specified control axis starts
deceleration stop. See figure below:
Figure 4-30: Relation between V-T chart of JOG movement and JOG-ON
signal
NOTE
NOTE
JOG-ON signal is a software digital signal where ON is
represented by value 1 and OFF by 0
ON(1)
OFF(0)
JOG-ON
V
T
signal
Содержание PCI-8254
Страница 2: ...ii Revision History Revision Date Description 2 00 2014 08 13 First release ...
Страница 8: ...viii Table of Contents Important Safety Instructions 209 Getting Service 211 ...
Страница 12: ...xii List of Figures ...
Страница 14: ...xiv List of Tables ...
Страница 24: ...10 Introduction ...
Страница 54: ...40 Getting Start with The Installation ...
Страница 78: ...64 Signal Connection ...
Страница 111: ...Motion Control Theory 97 PCI 8254 PCI 8258 MCP2 Bode plot page ...
Страница 165: ...Motion Control Theory 151 PCI 8254 PCI 8258 Example Figure 4 55 Continuous interpolation examples ...
Страница 222: ...208 Motion Control Theory ...