16
••
Operation Theorem
Digital Value
HEX value
Output Voltage
32767
0x7FFF
+9.99969V
16384
0x4000
+5.00000V
8192
0x2000
+2.50000V
1
0x0001
0.00031V
0
0x0000
0.00000V
-1
0xFFFF
-0.00031V
-8192
0xE000
-2.50000V
-16384
0xC000
-5.00000V
-32767
0x8001
-9.99969V
-32768
0x8000
-10.00000V
4.2 Current Output and Range Control
The current output is implemented by the precision voltage-to-current
converter XTR110. The current output channel n (An) is control by the
voltage of channel n (Vn). The block diagram of the current output
channels is shown in Fig 3.1.
X T R 1 1 0
5 0 O h m
O n B o a r d + 1 5 V
V n
A n
E x t e r n a l L o a d
(R e s i s t e r R
L
= 2 5 0 O h m t y p ical)
A . G N D
I o
C u r r e n t O u t p u t
R a n g e C o n t r o l
Fig 3.1