![ADLINK Technology MECS-7211 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/adlink-technology/mecs-7211/mecs-7211_user-manual_2852842050.webp)
Preliminary
50
MECS-7211
4.6.2 OEM ADLINK Get LED Status
NetFn=2Eh, Cmd=11h
Byte
Data Field
1-3
ADLINK Manufacturer ID – 005F13h, LS byte first.
4
LED ID:
01h= UID LED (Blue, UID led)
02h = USR LED (Yellow, HDD shared)
03h = Alert LED (Red)
04h = LED1 (HB Green, default blink)
05h = LED2 (HB Red, default off)
Other values: reserved
Response Field
1
Completion Code
2-4
ADLINK Manufacturer ID D of ran, LS byte first.
5
LED ID:
01h= UID LED (Blue)
02h = USR LED (Yellow, HDD shared)
03h = Alert LED (Red)
04h = LED1 (HB Green, default blink)
05h = LED2 (HB Red)
Other values: reserved
6
LED Function:
00h = LED OFF override.
01h - 1Eh = LED BLINKING override. The off duration is specified by
the value of this byte, and the on duration is specified by the value of
byte 7. Both values specify the time in hundreds of milliseconds (100
ms-3 s).
1Fh = LED is in Local Control state
20h-FEh Reserved
FF = LED ON override
7
On-duration :
The LED on-time in hundreds of milliseconds if (01h <= Byte 6 <= 1Eh)
and ignored otherwise set to 0h.