Preliminary
41
MECS-7211
3.15 BMC Firmware Update via Network
The MECS-7211 supports a BMC Chassis Management firmware, IPMI v2.0 compliant.
To install the BMC firmware via network, perform the following steps.
1. Install a Linux distribution, such as Ubuntu 14/16, to the client PC.
2. Install “expect” to your debug PC (ex: sudo apt-get install expect bash –y).
3. Configure the client PC network setting, let it can ping the BMC through the network.
4. Copy the BMC FW package “BMC_MECS-7211_Release_Vx.xx” and BIOS bin file to
the same folder to the client PC, and add Execution Authority to the adlinktool using
below command.
chmod +x *.sh
Update Procedure:
1. Check the IP of the BMC of MECS-7211. Power on the MECS-7211, boot the BMC to
Linux (username: sysadmin; Passwd: superuser), and type “ifconfig” check its IP
address.
2. On the debug PC, execute the following commands to perform the upgrade.
cd BMC_MECS-7211_Release_Vx.xx
cd FW
./adlinktool.sh bmc1 rom.ima 172.20.5.77