background image

Express-HR  

User’s Manual

Page 16

Pin No. Pin Name

Pin No. Pin Name

Pin No. Pin Name

Pin No. Pin Name

A1

GND (FIXED)

B1

GND (FIXED)

C1

GND FIXED)

D1

GND FIXED)

A2

GBE0_MDI3-

B2

GBE0_ACT#

C2

GND

D2

GND

A3

GB

B3

LPC_FRAME#

C3

USB_SSRX0-

D3

USB_SSTX0-

A4

GBE0_LINK100#

B4

LPC_AD0

C4

US

D4

US

A5

GBE0_LINK1000#

B5

LPC_AD1

C5

GND

D5

GND

A6

GBE0_MDI2-

B6

LPC_AD2

C6

USB_SSRX1-

D6

USB_SSTX1-

A7

GB

B7

LPC_AD3

C7

US

D7

US

A8

GBE0_LINK#

B8

LPC_DRQ0#

C8

GND

D8

GND

A9

GBE0_MDI1-

B9

LPC_DRQ1#

C9

USB_SSRX2-

D9

USB_SSTX2-

A10

GB

B10

LPC_CLK

C10

US

D10

US

A11

GND (FIXED)

B11

GND (FIXED)

C11

GND (FIXED)

D11

GND (FIXED)

A12

GBE0_MDI0-

B12

PW RBTN#

C12

USB_SSRX3-

D12

USB_SSTX3-

A13

GB

B13

SMB_CK

C13

US

D13

US

A14

GBE0_CTREF

B14

SMB_DAT

C14

GND

D14

GND

A15

SUS_S3#

B15

SMB_ALERT#

C15

DDI

D15

DDI1_CTRL

A16

S

B16

S

C16

DDI1_PAIR6-

D16

DDI1_CTRLDATA_AUX-

A17

SATA0_TX-

B17

SATA1_TX-

C17

RSVD

D17

RSVD

A18

SUS_S4#

B18

SUS_STAT#

C18

RSVD

D18

RSVD

A19

S

B19

S

C19

P

D19

P

A20

SATA0_RX-

B20

SATA1_RX-

C20

PCIE_RX6-

D20

PCIE_TX6-

A21

GND (FIXED)

B21

GND (FIXED)

C21

GND (FIXED)

D21

GND (FIXED)

A22

S

B22

S

C22

P

D22

P

A23

SATA2_TX-

B23

SATA3_TX-

C23

PCIE_RX7-

D23

PCIE_TX7-

A24

SUS_S5#

B24

PW R_OK

C24

DDI1_HPD

D24

RSVD

A25

S

B25

S

C25

DDI

D25

RSVD

A26

SATA2_RX-

B26

SATA3_RX-

C26

DDI1_PAIR4-

D26

DDI

A27

BATLOW #

B27

W DT

C27

RSVD

D27

DDI1_PAIR0-

A28

(S)ATA_ACT#

B28

AC/HDA_SDIN2

C28

RSVD

D28

RSVD

A29

AC/HDA_SYNC

B29

AC/HDA_SDIN1

C29

DDI

D29

DDI

A30

AC/HDA_RST#

B30

AC/HDA_SDIN0

C30

DDI1_PAIR5-

D30

DDI1_PAIR1-

A31

GND (FIXED)

B31

GND (FIXED)

C31

GND (FIXED)

D31

GND (FIXED)

A32

AC/HDA_BITCLK

B32

SPKR

C32

DDI2_CTRL

D32

DDI

A33

AC/HDA_SDOUT

B33

I2C_CK

C33

DDI2_CTRLDATA_AUX-

D33

DDI1_PAIR2-

A34

BIOS_DIS0#

B34

I2C_DAT

C34

DDI2_DDC_AUX_SEL

D34

DDI1_DDC_AUX_SEL

A35

THRMTRIP#

B35

THRM#

C35

RSVD

D35

RSVD

A36

USB6-

B36

USB7-

C36

DDI3_CTRL

D36

DDI

A37

USB6+

B37

USB7+

C37

DDI3_CTRLDATA_AUX-

D37

DDI1_PAIR3-

A38

USB_6_7_OC#

B38

USB_4_5_OC#

C38

DDI3_DDC_AUX_SEL

D38

RSVD

A39

USB4-

B39

USB5-

C39

DDI

D39

DDI

A40

USB4+

B40

USB5+

C40

DDI3_PAIR0-

D40

DDI2_PAIR0-

A41

GND (FIXED)

B41

GND (FIXED)

C41

GND (FIXED)

D41

GND (FIXED)

A42

USB2-

B42

USB3-

C42

DDI

D42

DDI

A43

USB2+

B43

USB3+

C43

DDI3_PAIR1-

D43

DDI2_PAIR1-

A44

USB_2_3_OC#

B44

USB_0_1_OC#

C44

DDI3_HPD

D44

DDI2_HPD

A45

USB0-

B45

USB1-

C45

RSVD

D45

RSVD

A46

USB0+

B46

USB1+

C46

DDI

D46

DDI

A47

VCC_RTC

B47

EXCD1_PERST#

C47

DDI3_PAIR2-

D47

DDI2_PAIR2-

A48

EXCD0_PERST#

B48

EXCD1_CPPE#

C48

RSVD

D48

RSVD

A49

EXCD0_CPPE#

B49

SYS_RESET#

C49

DDI

D49

DDI

A50

LPC_SERIRQ

B50

CB_RESET#

C50

DDI3_PAIR3-

D50

DDI2_PAIR3-

Row  A

Row  B

Row  C

Row  D

5.3

Pin Definitions

Pinouts for:

COM.0 R2.0 Type 6

C D

A B

A1

B1

C1

D1

A110

B110

C110

D110

Содержание Express-HR

Страница 1: ...Express HR User s Manual Manual Revision 2 00 Revision Date June 11 2012 Part Number 50 1J036 1000...

Страница 2: ...Express HR User s Manual Page 2 Revision History Release Date Change 2 00 June 11 2012 Initial release...

Страница 3: ...Super I O 10 2 8 TPM Trusted Platform Module 10 2 9 Power Specifications 10 2 10 Power Consumption 11 2 11 Operating Systems 12 2 12 Mechanical and Environmental 12 3 Function Diagram 13 4 Mechanical...

Страница 4: ...8 5 PCI Configuration Space Map 35 8 6 PCI Interrupt Routing Map 36 9 BIOS Setup Utility 37 9 1 Starting the BIOS 37 9 2 UEFI BIOS Setup Utility 38 9 3 Main Setup 39 9 4 Advanced Setup 40 9 5 Chipset...

Страница 5: ...sibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the European Union s Restric...

Страница 6: ...d instructions properly Additional information aids and tips that help users perform tasks Information to prevent minor physical injury component damage data loss and or program corruption when trying...

Страница 7: ...duler 2 0 1 0 XPDM support and DirectX Video Acceleration DXVA support for full AVC VC1 MPEG2 hardware decode Graphics outputs include VGA LVDS and three DDI ports supporting HDMI DVT DisplayPort or S...

Страница 8: ...QM67 Express f L3 Cache 6MB i7 2715QE 4MB i7 2655LE and i7 2610UE 3MB i5 2515E f BIOS AMI EFI with CMOS backup in 16 Mbit SPI BIOS f Debug Interface XDP SFF 26 extension for ICE debug f Hardware Moni...

Страница 9: ...on on configuring the DDI output DisplayPort DisplayPort is a VESA interface standard for digital display It defines a new license free royalty free state of the art digital audio video interconnect i...

Страница 10: ...eight ports USB 2 0 f SSD Optional SATA based Solid State Disk 8 16 32 GB 2 7 Super I O f Connected to LPC bus on carrier if needed 2 8 TPM Trusted Platform Module f Chipset Infineon SLB9635TT1 2 f Ty...

Страница 11: ...indows XP running BurnIn software Measurements were made with two 4GB 1066 MHz DDR3 SODIMM memory modules installed Intel Core i7 2715QE 2 1 GHz Power State 12V 5VSB Power Consumption Idle Windows XP...

Страница 12: ...urrent 3V Power 1 3 A 0 00000429 W 2 11 Operating Systems f Standard Support Windows XP 32 64 bit Windows Vista 32 64 bit Windows Server 2003 2008 f Extended Support BSP Embedded XP WES2009 BSP Embedd...

Страница 13: ...rt 0 5 SMBus Dual channel 24 bit LVDS 4x GP0 I2 C 8x USB 2 0 channel 0 7 CD SODIMM 2 1066 1333 MHz 1 8 GB DDR3 SPI 1 BIOS PCIe x1 port 7 HDA Audio LPC bus FDI SODIMM 2 1066 1333 MHz 1 8 GB DDR3 PCI Ex...

Страница 14: ...Express HR User s Manual Page 14 4 Mechanical Dimensions All tolerances 0 05 mm Other tolerances 0 2 mm...

Страница 15: ...cument that provides information on designing a custom carrier board for COM Express modules The design guide includes reference schematics for the external circuitry required to implement the various...

Страница 16: ...SATA2_RX B25 SATA3_RX C25 DDI1_PAIR4 D25 RSVD A26 SATA2_RX B26 SATA3_RX C26 DDI1_PAIR4 D26 DDI1_PAIR0 A27 BATLOW B27 WDT C27 RSVD D27 DDI1_PAIR0 A28 S ATA_ACT B28 AC HDA_SDIN2 C28 RSVD D28 RSVD A29 AC...

Страница 17: ...77 LVDS_B3 C77 RSVD D77 RSVD A78 LVDS_A3 B78 LVDS_B3 C78 PEG_RX8 D78 PEG_TX8 A79 LVDS_A3 B79 LVDS_BKLT_EN C79 PEG_RX8 D79 PEG_TX8 A80 GND FIXED B80 GND FIXED C80 GND FIXED D80 GND FIXED A81 LVDS_A_CK...

Страница 18: ...Low I 3 3 PU 8k2 3 3Vsb A28 ATA_ACT ATA_LED SATA LED O 3 3 PU 10k 3 3V A29 AC_SYNC AC_SYNC AC 97 Sync O 3 3 int PD 20k in QM57 A30 AC_RST AC_RST AC 97 Reset O 3 3 int PD 20k in QM57 A31 GND Ground PW...

Страница 19: ...DS_VDDEN LVDS Panel Power O 2 5 PD 10k A78 LVDS_A3 LVDS_AP3 LVDS Channel A O DP A79 LVDS_A3 LVDS_AN3 LVDS Channel A O DP A80 GND Ground PWR A81 LVDS_A_CK LVDS_CLKAP LVDS Channel A O DP A82 LVDS_A_CK L...

Страница 20: ...SATA 3 Receive Data I DP B27 WDT Watch Dog Timer O 3 3 B28 AC_SDIN2 AC_SDATAIN2 I 3 3 int PD 20k in QM57 B29 AC_SDIN1 AC_SDATAIN1 I 3 3 int PD 20k in QM57 B30 AC_SDIN0 AC_SDATAIN0 I 3 3 int PD 20k in...

Страница 21: ...Data2 O DP B77 LVDS_B3 LVDS_BP3 LVDS Channel B Data3 O DP B78 LVDS_B3 LVDS_BN3 LVDS Channel B Data3 O DP B79 LVDS_BKLT_EN LVDS Panel Backlight Enable O 3 3 PD 100k B80 GND Ground PWR B81 LVDS_B_CK LVD...

Страница 22: ...CLKIN O DP C30 DDI1_PAIR5 SDVO1_TVCLKIN O DP C31 GND Ground PWR C32 DDI2_CTRLCLK_AUX DP2_AUX HDMI2_CTRLCLK IO 3 3 C33 DDI2_CTRLDATA_AUX DP2_AUX HDMI2_CTRLDATA IO 3 3 C34 DDI2_DDC_AUX_SEL DP2 and HDMI2...

Страница 23: ...I DP C76 GND Ground PWR C77 RSVD FAN_TACH I 5 C78 PEG_RX8 PCIe 8 Recieve I DP C79 PEG_RX8 PCIe 8 Recieve I DP C80 GND Ground PWR C81 PEG_RX9 PCIe 9 Recieve I DP C82 PEG_RX9 PCIe 9 Recieve I DP C83 RSV...

Страница 24: ...1_PAIR1 DP1_LANE1 TMDS1_DATA1 SDVO1_GRN O DP D30 DDI1_PAIR1 DP1_LANE1 TMDS1_DATA1 SDVO1_GRN O DP D31 GND Ground PWR D32 DDI1_PAIR2 DP1_LANE2 TMDS1_DATA0 SDVO1_BLU O DP D33 DDI1_PAIR2 DP1_LANE2 TMDS1_D...

Страница 25: ...EG_TX7 PCIe 7 Transmit O DP D76 GND Ground PWR D77 RSVD NC D78 PEG_TX8 PCIe 8 Transmit O DP D79 PEG_TX8 PCIe 8 Transmit O DP D80 GND Ground PWR D81 PEG_TX9 PCIe 9 Transmit O DP D82 PEG_TX9 PCIe 9 Tran...

Страница 26: ...t OA Analog Output OD Digital Output I O DP Differential Pair Input Output O DP Differential Pair Output I DP Differential Pair Input PWR Power or Ground STO Strapping Output PU Pull Up Resistor PD Pu...

Страница 27: ...output type go to the BIOS setup utility and navigate to the following screens Chipset System Agent SA Configuration Graphics Configuration LCD Control DDI Function Choose Select from the following op...

Страница 28: ...initial value to zero When the system is operating normally the software that sets the intial value periodically resets the counter so that the it never reaches zero If the counter reaches zero befor...

Страница 29: ...PI or GPO Pin Signal Type AIDI ID bit Remark A54 GPI0 0 Express HR can configure this pin for GPI and GPO A63 GPI1 1 Express HR can configure this pin for GPI and GPO A67 GPI2 2 Express HR can configu...

Страница 30: ...simple APIs at the application level to support these functions and adds alarm functions when voltage or temperature levels exceed the upper or lower limit set by the user On the Express HR the follo...

Страница 31: ...f 60h 4 GB 144 MB 12MB 172KB F7C2B000 F7C2B00F 16 B ME B0D16F0 4 GB 144 MB 12MB 164KB F7C29000 F7C29FFF 4 KB Remote Keyboard and Text KT B0D16F3 When iAMT support 4 GB 144 MB 12MB 160KB F7C28000 F7C28...

Страница 32: ...uivalent 060 062 064 066 8742 equivalent keyboard 061 NMI control and status 070 077 Real Time Clock Controller bit 7 NMI mask 080 091 DMA page register 092 Reset Bit 0 Fast GateA20 Bit 1 093 09F DMA...

Страница 33: ...yboard controller IRQ1 via SERIRQ No 2 Cascade interrupt from slave PIC Slave controller INTR output No 3 Serial Port 2 COM2 IRQ3 via SERIRQ No 4 Serial Port 1 COM1 IRQ4 via SERIRQ No 5 Available N A...

Страница 34: ...a SERIRQ No 6 Reserved N A No 7 Reserved N A No 8 Real time clock Internal RTC HPET 1 No 9 SCI PCI IRQ9 via SERIRQ No 10 Reserved N A No 11 Reserved N A No 12 PS 2 Mouse IRQ12 via SERIRQ No 13 Math Pr...

Страница 35: ...rnal PCI Express Root port 3 00h 1Ch 03h Internal PCI Express Root port 4 00h 1Ch 04h Internal PCI Express Root port 5 00h 1Ch 05h Internal PCI Express Root port 6 00h 1Ch 06h Internal PCI Express Roo...

Страница 36: ...INT B INT B C INT C INT C X X X D INT D INT D X X E X F G X X X H 8 6 PCI Interrupt Routing Map PIRQ PCIE port 0 PCIE port 1 PCIE port 2 PCIE port 3 PCIE port 4 PCIE port 5 PCIE port 6 PCIE port 7 A I...

Страница 37: ...S ver A1 0 9 1 Starting the BIOS To enter the setup screen follow these steps 1 Power on the motherboard 2 Press the Delete key on your keyboard when you see the following text prompt Press DEL or Del...

Страница 38: ...d Minus Arrow keys allow you to change the field value of a particular setup item For example Date and Time Tab The Tab key allows you to select Aptio TSE fields F1 This key displays the general help...

Страница 39: ...Page 39 Express IA533 User s Manual Page 39 Express IA533 User s Manual Express HR User s Manual Page 39 Page 39 Express HR User s Manual 9 3 Main Setup System and Board Information...

Страница 40: ...guration Setting incorrect or conflicting values in Advanced BIOS Setup may cause system malfunctions Launch PXE OpROM Enabled Set this value to allow the option for Legacy Network Device Disabled Set...

Страница 41: ...e the system will enter when the Suspend button is pressed The Default value is set as S3 Suspend to RAM Emulation AT ATX When AT mode is set Windows will not turn off power when performing a shutdown...

Страница 42: ...Express HR User s Manual Page 42 ACPI RTC Wake Sets the ACPI RTC Wake time 9 4 3 RTC Wake Settings 9 4 2 Trusted Computing...

Страница 43: ...xecute Disable Bit Execute Disable Bit can prevent certain classes of malicious buffer overflow attacks when combined with a supporting OS Hardware Prefetcher This feature is used for reducing the wai...

Страница 44: ...ple operating systems separately and simultaneously enabling one system to function virtually as several systems Options are Enabled Disabled 9 4 5 SATA Configuration SATA Controller Enable or disable...

Страница 45: ...Express HR User s Manual Page 45 Page 45 Express HR User s Manual 9 4 6 Intel TXT LT Configuration This option allows the user to configure Intel Trusted Execution Technology 9 4 7 PCH FW Configuratio...

Страница 46: ...Configuration This option allows the user to configure Intel Anti Theft Technology Intel Anti Theft Tech Enables or disables Intel Anti Theft technology and sets the maximum number of recovery attempt...

Страница 47: ...s Manual Page 47 Page 47 Express HR User s Manual Legacy USB Support Enables and disables Legacy USB support Disabling this option will keep USB devices available only for EFI applications 9 4 10 USB...

Страница 48: ...ed by EHCI driver Configuration options Enable Disable USB Transfer Time out The time out value for Control Bulk and Interrupt transfers Options 10 20 30 40 sec Device Reset Timeout USB mass storage d...

Страница 49: ...Description Manual Setting by manual PWM Auto Mode Module Link to Module temperature Auto Mode ADT 7490 Link to ADT 7490 temperature Auto Mode CPU Link to CPU temperature Fan1 2 Expect PWM Output Sets...

Страница 50: ...l port 1 2 Options are Enabled Disabled Change Settings This option specifies the base I O port address and Interrupt Request address of serial port 1 2 Configuration options Auto 3F8 3E8 2F8 2E8 9 4...

Страница 51: ...e 51 Page 51 Express HR User s Manual 9 4 13 Serial Port Console Redirection Console Redirection Options are Enabled Disabled Console Redirection Settings The settings specify how the host computer an...

Страница 52: ...e to 7 or 8 Parity Set this option to select parity for console redirection The settings for this value are None Even Odd Mark and Space Stop Bits Stop bits indicate the end of a serial data packet Th...

Страница 53: ...age 53 Express HR User s Manual 9 4 14 Sandy Bridge PPM Configuration This option allows the user to view and configure the settings for processor power management EIST Allows the user to enable disab...

Страница 54: ...set Configuration Select the Chipset tab from the setup screen to enter the Chipset Configuration screen 9 5 1 System Agent SA Configuration VT d This option allows the user to enable disable Intel Vi...

Страница 55: ...e user to enable disable the integrated graphics GTT Size Allows the user to set the Graphics Translation Table size Options 1MB 2MB Aperture Size Allows the user to set the Aperture Size Options 128M...

Страница 56: ...1400x1050 DCLK 122MHz 1600x1200 LVDS 1366x768 LVDS 1680x1050 LVDS 1920x1200 LVDS 1024x768 LVDS 1280x800 LVDS 1920x1080 LVDS 1024x600 LVDS 1280x600 LVDS Active LFP Options No LVDS Int LVDS Panel Color...

Страница 57: ...Page 57 Express IA533 User s Manual Page 57 Express IA533 User s Manual Express HR User s Manual Page 57 Page 57 Express HR User s Manual Memory Configuration NB PCIe Configuration...

Страница 58: ...er loss The options for this value are Last State Power On and Power Off Option Description Power Off Set this value to always power off the system while AC power is restored Power On Set this value t...

Страница 59: ...ion Allows the user to enable disable the USB Enhanced Host Controller Interfaces PCI Express Configuration Target Link Speed Options GEN1 GEN2 PCIE Ports 0 3 Configuration Allows the user to set the...

Страница 60: ...rd press the Number Lock key located on the upper left hand corner of the 10 key pad The Number Lock LED on the keyboard will light up when the Number Lock is engaged On Set this value to allow the Nu...

Страница 61: ...rupt 19 Capture Allows option ROMs to trap Int 19 Set this value to Enabled Disabled Boot Option Priorities This option sets the priorities of the boot options The user can change the priorities by se...

Страница 62: ...ecurity Setup Administrator Password Use this option to set a password for administrators with full control of the BIOS setup utility User Password Use this option to set a password for users with lim...

Страница 63: ...save changes and continue booting the system New configuration parameters will take effect after the next system restart Discard Changes and Exit Select this option to quit Setup without saving change...

Страница 64: ...ES to Save Changes and continue Discard Changes Discard any unsaved changes Restore Defaults Restore standard default values for all the setup options Save as User Defaults Save the changes made so fa...

Страница 65: ...are very useful for debugging problems that occur during the preboot process Beep codes are used by the BIOS to indicate a serious or fatal error They are used when an error occurs before the system v...

Страница 66: ...ription 0x0 Not used Progress Codes 0x1 Power on Reset type detection soft hard 0x2 AP initialization before microcode loading 0x3 North Bridge initialization before microcode loading 0x4 South Bridge...

Страница 67: ...l Presence Detect SPD data reading 0x2C Memory initialization Memory presence detection 0x2D Memory initialization Programming memory timing information 0x2E Memory initialization Configuring memory 0...

Страница 68: ...ess Codes 0xE0 S3 Resume is stared S3 Resume PPI is called by the DXE IPL 0xE1 S3 Boot Script execution 0xE2 Video repost 0xE3 OS S3 wake vector call 0xE4 0xE7 Reserved for future AMI progress codes 0...

Страница 69: ...tarted 0x6A North Bridge DXE SMM initialization is started 0x6B North Bridge DXE initialization North Bridge module specific 0x6C North Bridge DXE initialization North Bridge module specific 0x6D Nort...

Страница 70: ...Reset 0xA2 IDE Detect 0xA3 IDE Enable 0xA4 SCSI initialization is started 0xA5 SCSI Reset 0xA6 SCSI Detect 0xA7 SCSI Enable 0xA8 Setup Verifying Password 0xA9 Start of Setup 0xAA Reserved for ASL see...

Страница 71: ...ailable DXE Beep Codes of Beeps Description 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 1 Invalid password 6 Flas...

Страница 72: ...ription 0x5 OEM SEC initialization before microcode loading 0xA OEM SEC initialization after microcode loading 0x1D 0x2A OEM pre memory initialization codes 0x3F 0x4E OEM PEI post memory initializatio...

Страница 73: ...ver ventilation openings Make sure to use recommended voltage and power source settings Always install and operate equipment near an easily accessible electrical socket outlet Secure the power cord do...

Страница 74: ...3 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology Beijing Address 1 E 801 100085 Rm...

Страница 75: ...iaison Office Address 1675 12 8 8F Mointer B D 1675 12 Seocho Dong Seocho Gu Seoul 137 070 Korea Tel 82 2 2057 0565 Fax 82 2 2057 0563 Email korea adlinktech com ADLINK Technology Singapore Pte Ltd Ad...

Страница 76: ......