Function Library
57
EOS-1200
Parameter(s)
CardNumber
ID of the card for release.
Mode
Operating mode for adding or removing messages, wherein
0: Remove an existing message interrupt event defined
argument evt.
1: Add a new message for an interrupt event defined
evt
Handle of the INT event to handle
windowHandle
Handle to the window in which a Windows message will be
received when the specified INT event occurs; if windoHan-
dle is 0, no Windows messages will be sent
Message
User-defined message issued when the specified INT event
occurs. The message can be of any value. In Windows, the
message can be set to a value including any Windows pre-
defined messages, such as WM_PAINT. To define a custom
message, any value ranging from WM_USER (0x400) to
0x7fff can be used, this range reserved by Windows for
same.
callbackAddr
Address of the user callback function. The PCIS-DASK calls
this function when the specified INT event occurs. If no call-
back function is required, set callbackAddr to 0.
Return Code(s)
NoError
ErrorInvalidCardNumber
ErrorCardNotRegistered
ErrorFuncNotSupport