background image

14

Important Safety Instructions

Leading

EDGE COMPUTING

Never attempt to repair the device, which should only be 
serviced by qualified technical personnel using suitable 
tools

A Lithium-type battery may be provided for uninterrupted 
backup or emergency power.

The device must be serviced by authorized technicians 
when:

The power cord or plug is damaged

Liquid has entered the device interior

The device has been exposed to high humidity and/or 
moisture

The device is not functioning or does not function 
according to the User’s Manual

The device has been dropped and/or damaged and/or 
shows obvious signs of breakage

Disconnect the power supply cord before loosening the 
thumbscrews and always fasten the thumbscrews with a 
screwdriver before starting the system up

It is recommended that the device be installed only in a 
server room or computer room where access is:

Restricted to qualified service personnel or users familiar 
with restrictions applied to the location, reasons therefor, 
and any precautions required

Only afforded by the use of a tool or lock and key, or 
other means of security, and controlled by the authority 
responsible for the location

CAUTION:

Risk of explosion if battery is replaced with one of an incorrect 
type; please dispose of used batteries appropriately. 

Risque d’explosion si la pile est remplacée par une autre de 
type incorrect. Veuillez jeter les piles usagées de façon appro-
priée.

Содержание DIN-1040

Страница 1: ...Leading EDGE COMPUTING DIN 1040 DIN Board User s Manual Manual Rev 1 0 Revision Date Dec 30 2017 Part No 50 11257 1000...

Страница 2: ...ii Leading EDGE COMPUTING Revision History Revision Release Date Description of Change s 1 0 Dec 30 2017 Initial Release...

Страница 3: ...en if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the...

Страница 4: ...s properly NOTE NOTE Additional information aids and tips that help users perform tasks CAUTION Information to prevent minor physical injury component dam age data loss and or program corruption when...

Страница 5: ...Indicators 2 1 3 1 Digital I O and Power 3 1 3 2 RS 232 4 1 3 3 Main Power 5 1 3 4 PWM LED Control Out 5 1 3 5 Hardware Trigger Input 6 1 3 6 Hardware Trigger Input 6 1 3 7 General Purpose Isolated Di...

Страница 6: ...vi Table of Contents Leading EDGE COMPUTING This page intentionally left blank...

Страница 7: ...Table 1 5 PWM LED Pin Assignments 5 Table 1 6 Hardware Trigger Input Pin Assignments 6 Table 1 7 Trigger Input Electrical Specification 6 Table 1 8 Isolated Digital Input Pin Assignments 7 Table 1 9...

Страница 8: ...viii List of Tables Leading EDGE COMPUTING This page intentionally left blank...

Страница 9: ...ure 1 1 I O Panel 2 Figure 1 2 Hardware Trigger Input Circuit 6 Figure 1 3 Isolated Digital Input Circuit 7 Figure 1 4 Isolated Digital Output Circuit 9 Figure 1 5 Connection Relay Application Circuit...

Страница 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank...

Страница 11: ...or output Digital or exposure output function as configured by software Operating voltage range up to 24VDC Open collector sink currents max 300 mA Overcurrent protection per channel Digital Input 4 c...

Страница 12: ...USB 4 channel USB 1 1 full speed DC Output Isolation 5VDC 15 max 100mA DC Input 24V DC 10 max 30 VDC DC Input Power Protection Over current fuse 3A Power reverse Mechanical Environmental Dimensions 12...

Страница 13: ...I O and power F Isolated Digital Output B RS 232 G Isolated Digital Input C Power H DI O status LED D PWM LED Output I LAN Port E Hardware Trigger Input J USB Port Type A x4 K USB Port Type B Pin Sign...

Страница 14: ...ments 1 3 2 RS 232 A D SUB9 male connector Table 1 3 System UART Pin Assignments 8 System PWR 21 DO0 Strobe out 0 9 System PWR 22 DI3 10 GND 23 DI0 11 GND 24 DI2 12 GND 25 DI1 13 GND 26 GND Pin Signal...

Страница 15: ...0 1 3 3 Main Power Table 1 4 Power Pin Assignments 1 3 4 PWM LED Control Out Table 1 5 PWM LED Pin Assignments Pin Signal 1 Power in 2 GND 3 Isolated 5V power out 4 Isolated GND Pin Signal 1 PWN outpu...

Страница 16: ...rcuit Table 1 7 Trigger Input Electrical Specification 1 3 7 General Purpose Isolated Digital Input Four isolated digital input channels are provided Pin Signal 1 Trigger input 2 Trigger input Min Max...

Страница 17: ...gure 1 3 Isolated Digital Input Circuit Pin Signal 1 DI0 2 DI0 3 DI1 4 DI1 5 DI2 6 DI2 7 DI3 8 DI3 9 Isolated GND Min Max Number of Channels 4 digital inputs Input Resistance 2 4K Normal Input High Th...

Страница 18: ...a 1 logic high is written by FPGA to a DO channel sink current passes through the transistors and the DO channel goes low and when a 0 logic low is written by FPGA to a DO channel no cur rent passes t...

Страница 19: ...er of Channels 4 digital outputs Output Type Sink current for each channel Max 300mA Channel Output Working Voltage Max 24V Overcurrent Protection Max 750mA per channel 25 C Output Inactive Leakage Cu...

Страница 20: ...on ON DC power off OFF DI0 Green DI high ON DI low OFF DI1 Green DI high ON DI low OFF DI2 Green DI high ON DI low OFF DI3 Green DI high ON DI low OFF DO0 Yellow DO active ON DO inactive OFF DO1 Yell...

Страница 21: ...Introduction 11 DIN 1040 1 4 Accessory Connection Figure 1 6 DIN 1040 Accessory Connection...

Страница 22: ...12 Introduction Leading EDGE COMPUTING Table 1 12 DIN 1040 Accessories P N Accessory 30 01203 0010 VGA USB cable 30 01246 0000 Gig E cable 30 01201 0000 Power DI O cable...

Страница 23: ...e of 50 C When installing mounting or uninstalling removing device or when removal of a chassis cover is required for user ser vicing See Introduction on page 1 Turn off power and unplug any power cor...

Страница 24: ...f breakage Disconnect the power supply cord before loosening the thumbscrews and always fasten the thumbscrews with a screwdriver before starting the system up It is recommended that the device be ins...

Страница 25: ...ng this surface could result in bodily injury To reduce risk allow the surface to cool before touching RISQUE DE BR LURES Ne touchez pas cette surface cela pourrait entra ner des blessures Pour viter...

Страница 26: ...16 Important Safety Instructions Leading EDGE COMPUTING This page intentionally left blank...

Страница 27: ...60 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel...