background image

BIOS Setup

 55

DEX-100

Power Up

Lists Power-Up Watchdog status.

Содержание DEX-100

Страница 1: ...Leading EDGE COMPUTING Manual Rev 1 0 Revision Date Dec 30 2017 Part No 50 100 DEX 100 Data Extraction System User s Manual...

Страница 2: ...ii Leading EDGE COMPUTING Revision History Revision Release Date Description of Change s 1 0 Dec 30 2017 Initial Release...

Страница 3: ...n if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the E...

Страница 4: ...s properly NOTE NOTE Additional information aids and tips that help users perform tasks CAUTION Information to prevent minor physical injury component dam age data loss and or program corruption when...

Страница 5: ...4 1 Power Button 9 1 4 2 VGA Out 9 1 4 3 DisplayPort 10 1 4 4 PS 2 Ports 11 1 4 5 Serial ports COM1 and COM2 12 1 4 6 USB Ports 13 1 4 7 LAN Ports 14 1 4 8 USB Micro b Connector 16 1 4 9 DI Connectors...

Страница 6: ...ime System Date 32 A 1 3 Board Information 33 A 2 Advanced 34 A 2 1 CPU Configuration 35 A 2 2 Graphics Configuration 36 A 2 3 Onboard Device Configuration 37 A 2 4 Advanced Power Management 45 A 2 5...

Страница 7: ...Table of Contents vii DEX 100 Getting Service 69...

Страница 8: ...viii Table of Contents Leading EDGE COMPUTING...

Страница 9: ...1 5 COM1 and COM2 Connectors Pin Assignments 12 Table 1 6 USB 2 0 Pin Assignments 13 Table 1 7 USB 3 0 Pin Assignments 14 Table 1 8 LAN Port Pin Definitions 15 Table 1 9 LAN Port LED Legend 15 Table 1...

Страница 10: ...x List of Tables Leading EDGE COMPUTING This page intentionally left blank...

Страница 11: ...ors 12 Figure 1 11 USB 2 0 13 Figure 1 12 USB 3 0 13 Figure 1 13 LAN Port 15 Figure 1 14 USB Micro b Connector 16 Figure 1 15 DI Connector 17 Figure 1 16 Right Side Panel I O 18 Figure 1 17 Left Side...

Страница 12: ...xii List of Figures Leading EDGE COMPUTING This page intentionally left blank...

Страница 13: ...g required with the system acquiring and processing targeted display content from multiple pages 2 DI connections interface with external devices and extend M2M function enabling integration of new de...

Страница 14: ...s w Windows default font 9 pt speed may vary with resolution and font size Data Extraction and User Full Machine Control modes hard or soft switchable by user Script generation Over 100 script command...

Страница 15: ...GA input DVI input VGA output DVI output DisplayPort For local DP display 2x isolated DI Power Supply DC Input 12 36 VDC AC Input Optional 40W AC DC adapter LED Indicators Power Storage WDT Mechanical...

Страница 16: ...Operating 100G half sine 11 ms duration w SD mSATA SSD EMC CE FCC Class A EN610006 4 EN61000 6 2 Safety UL by CB Power Consumption Power off 1 2W 0 05A 24VDC In shutdown mode with DC input and only U...

Страница 17: ...Introduction 5 DEX 100 1 3 Mechanical Drawings Figure 1 1 Front View NOTE NOTE All dimensions shown are in millimeters mm unless otherwise stated 140 0 5 80...

Страница 18: ...6 Introduction Leading EDGE COMPUTING Figure 1 2 Top View Figure 1 3 Right Side View 140...

Страница 19: ...Introduction 7 DEX 100 Figure 1 4 Left Side View Figure 1 5 Rear Side View...

Страница 20: ...ont Panel I O I O connectors and controls on the DEX 100 front panel as labeled are as follows Power button VGA Out DisplayPort PS 2 keyboard port PS 2 mouse port Serial ports COM1 and COM2 USB2 0 por...

Страница 21: ...w ers down the unit LED indicator functions as follows Table 1 1 Power Button LED Indicator Legend 1 4 2 VGA Out One VGA connector for output supports 1920x1080 60Hz timing signal Figure 1 7 VGA Out C...

Страница 22: ...2160 30Hz Figure 1 8 DisplayPort Connector 4 ID2 RES 12 ID1 SDA 5 GND 13 HSync 6 RED_RTN 14 VSync 7 GREEN_RTN 15 ID3 SCL 8 BLUE_RTN Pin Signal Pin Signal 1 CN_DP0_P 2 GND 3 CN_DP0_N 4 CN_DP1_P 5 GND 6...

Страница 23: ...s Two PS 2 ports support keyboard and mouse connection Figure 1 9 PS 2 Port Table 1 4 PS 2 Port Pin Assignment 17 CN_AUX_N 18 DDP_HPD 19 GND 20 P3V3 Pin Signal Description 1 DATA Data 2 N A N C b 3 GN...

Страница 24: ...ainboard with RS 232 the default and COM2 supports RS 232 only Figure 1 10 COM1 and COM2 Connectors Table 1 5 COM1 and COM2 Connectors Pin Assignments Pin Signal RS232 RS422 RS485 1 DCD TXD422 485DATA...

Страница 25: ...USB 3 0 and 2USB 2 0 ports each provide 5V power for con nected devices Figure 1 11 USB 2 0 Table 1 6 USB 2 0 Pin Assignments Figure 1 12 USB 3 0 Pin Signal 1 Vcc 2 UV0 3 UV0 4 GNE Pin Signal 1 USB3 0...

Страница 26: ...3Qav traffic shaper Interrupt moderation VLAN support IP checksum offload PCIe OBFF Optimized Buffer Flush Fill Four transmit and four receive queues RSS and MSI X to lower CPU utilization in multi c...

Страница 27: ...E T 100BASE TX 1000BASE T 1 TX LAN_MDI0 2 TX LAN_MDI0 3 RX LAN_MDI1 4 N A LAN_MDI2 5 N A LAN_MDI2 6 RX LAN_MDI1 7 N A LAN_MDI3 8 N A LAN_MDI3 LED Activity LED1 Active Link Off No Link Orange Link Acti...

Страница 28: ...micro b connectors for connection to machine PC Figure 1 14 USB Micro b Connector Table 1 10 USB Micro b Connector Pin Definitions 1 4 9 DI Connectors Dual channel digital input function is provided w...

Страница 29: ...V Enabled 0V open Disabled 24V open Disabled 2 VCOM 0V 24V 3 Digital input 1 24V Enabled 0V Enabled 0V open Disabled 24V open Disabled Indicator Color Description U1 Green User defined U2 Green User d...

Страница 30: ...Leading EDGE COMPUTING 1 5 Right Side I O Connectors Figure 1 16 Right Side Panel I O I O connectors and controls on the DEX 100 right side panel as labeled are as follows VGA In PS 2 mouse port PS 2...

Страница 31: ...and controls on the DEX 100 left side panel as labeled are as follows DC Power Connector DVI port MPC DVI port 1 6 1 DC Power Connector Consists of V chassis ground and V pins V and V pins accept DC p...

Страница 32: ...Supply Connector Table 1 13 DC Power Supply Pin Assignments 1 6 2 DVI Port Both DVI D connectors one for input and the other for output sup port 1920x1080 60Hz timing signal Figure 1 19 DVI Port Pin S...

Страница 33: ...1 Isolated Digital Input Circuits The input can accept voltages up to 24V with extra 10k input resistors Rs Connections between outside signals are as fol lows Figure 1 20 Digital Input Sample Applica...

Страница 34: ...22 Introduction Leading EDGE COMPUTING This page intentionally left blank...

Страница 35: ...ion Obtain authorization from your dealer before returning any product to ADLINK Ensure that the fol lowing items are included in the package DEX 100 DI Connector DC Power Connector Recovery CD Techni...

Страница 36: ...24 Getting Started Leading EDGE COMPUTING Figure 2 1 Wall mount with Rear Panel Up Figure 2 2 Wall mount with Right Side Panel Up...

Страница 37: ...eft Panel Up Attach the provided wall mount brackets in the four screw holes on the underside of the chassis according to the desired configuration wall mount with rear panel up is shown as an example...

Страница 38: ...ght side up and left side up configurations 2 4 1 DIN Rail Mount w Right Side Up 1 Place the terminal plate with VGA label up and secure the provided DIN rail bracket via the two screw holes on the re...

Страница 39: ...Getting Started 27 DEX 100...

Страница 40: ...il Mount w Left Side Up 1 Place the terminal plate with DVI label up and secure the provided DIN rail bracket via the two screw holes on the rear side of the terminal plate 2 Secure the terminal plate...

Страница 41: ...om http www adlinktech com and install Chipset Graphics Ethernet USB3 Serial I O TXE Intel Trusted Execution Technology DEX PRO Utility NOTE NOTE Due to lack of controller support under Windows 10 suc...

Страница 42: ...30 Getting Started Leading EDGE COMPUTING This page intentionally left blank...

Страница 43: ...s menus for configuring settings and enabling features of the DEX 100 series Most users do not need to use the BIOS setup program as the DEX 100 ships with default settings that work well for most con...

Страница 44: ...ersion and Board version A 1 2 System Time System Date Changes system time and date Highlight System Time or System Date using the up or down Arrow keys Enter new values using the keyboard then Enter...

Страница 45: ...nufacturing date last repair date and MAC ID As well Runtime Statistics are listed including total run time current runtime power cycles boot cycles and boot reason NOTE NOTE The time is in 24 hour fo...

Страница 46: ...34 BIOS Setup Leading EDGE COMPUTING A 2 Advanced CAUTION Setting incorrect or conflicting values in Advanced BIOS Setup may cause system malfunction...

Страница 47: ...res Number of cores to enable in each processor package Intel Virtualization Technology When enabled allows a VMM to utilize the additional hardware capabilities provided by Vanderpool Technology VT d...

Страница 48: ...Critical Trip Point Temperature threshold of the Critical Trip Point Passive Cooling Trip Point Temperature threshold of the Passive Cooling Trip Point A 2 2 Graphics Configuration GTT Size Sets GTT s...

Страница 49: ...mory used by internal graphics device DVMT Total Gfx Mem Sets size of DVMT5 0 total graphic memory used by internal graphics device A 2 3 Onboard Device Configuration COM1 Control Selects COM1 mode fr...

Страница 50: ...NG HSUART Enables disables LPSS HSUART support LAN 1 Intel I210 Enables disables LAN device 1 LAN 2 Intel I210 Enables disables LAN device 2 Realtek Audio Support Enables disables Realtek audio device...

Страница 51: ...COM 1 console redirection Console Redirection Settings COM 1 Terminal Type Emulation ANSI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color function keys etc VT UTF8 Us...

Страница 52: ...Mark and Space Parity do not allow for error detection and can be used as an additional data bit Stop Bits Indicate the end of a serial data packet a start bit indicates the beginning with standard se...

Страница 53: ...ection Resolution In legacy OS the number of rows and columns supporting redi rection Putty KeyPad Selects FunctionKey and KeyPad on PuTTY Redirection After BIOS Post When Bootloader is selected Legac...

Страница 54: ...s Disables COM 2 console redirection Console Redirection Settings COM 2 Terminal Type Emulation ANSI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color function keys etc...

Страница 55: ...d Space Parity do not allow for error detection and can be used as an additional data bit Stop Bits Indicate the end of a serial data packet a start bit indicates the beginning with standard setting 1...

Страница 56: ...S Redirection Resolution In legacy OS the number of rows and columns supporting redi rection Putty KeyPad Selects FunctionKey and KeyPad on PuTTY Redirection After BIOS Post When Bootloader is selecte...

Страница 57: ...de does not support S3 S4 State After G3 Specifies state to enter when power is re applied after a power failure G3 state RTC Wake system from S5 Enables disables System Wake on alarm event where sele...

Страница 58: ...1 LAN 2 Wake Enables disables onboard Wake on LAN for 2 A 2 5 USB Configuration XHCI Hand off A workaround for OS without XHCI handoff support where XHCI ownership change should be claimed by the XHCI...

Страница 59: ...USB mass storage device Start Unit command timeout Device power up delay Maximum time the device will take before reporting to the Host Controller where Auto uses default value for a Root port 100 ms...

Страница 60: ...GE COMPUTING A 2 7 TPM Configuration Security Device Support Enables disables BIOS support for security device when enabled OS will not show the security device and TCG EFI protocol and INT1A interfac...

Страница 61: ...BIOS Setup 49 DEX 100 A 2 8 Network Stack Configuration Network Stack Enables disables UEFI network stack...

Страница 62: ...50 BIOS Setup Leading EDGE COMPUTING A 2 9 System Management Shows SEMA firmware and bootloader versions and build dates...

Страница 63: ...BIOS Setup 51 DEX 100 SEMA Features Shows features supported by the SEMA version...

Страница 64: ...52 BIOS Setup Leading EDGE COMPUTING Temperatures Shows current CPU temperature and current startup mini mum and maximum board temperatures...

Страница 65: ...BIOS Setup 53 DEX 100 Power Consumption Shows current input current and power as well as system volt ages...

Страница 66: ...54 BIOS Setup Leading EDGE COMPUTING Flags Shows BMC flags with exception codes...

Страница 67: ...BIOS Setup 55 DEX 100 Power Up Lists Power Up Watchdog status...

Страница 68: ...56 BIOS Setup Leading EDGE COMPUTING A 2 10 Miscellaneous OS Selection Allows selection of active OS...

Страница 69: ...BIOS Setup 57 DEX 100 A 2 11 Intel I210 Gigabit Network Connection Blink LEDs Identifies the physical network port by flashing the associated LED...

Страница 70: ...58 BIOS Setup Leading EDGE COMPUTING A 2 12 NIC Configuration Link Speed Specifies the port speed used for the selected boot protocol Wake On LAN Enables server power up using an in band magic packet...

Страница 71: ...able SC BIOS Lock which must be enabled to ensure SMM flash protection NOTE NOTE If only the Administrator s password is set only access to Setup is limited and authorization requested only when enter...

Страница 72: ...Leading EDGE COMPUTING A 3 1 Secure Boot Shows System Mode and Secure Boot status NOTE NOTE Secure Boot is activated when Platform Key PK is enrolled where System Mode is User Deployed and CSM functio...

Страница 73: ...ation key with 65535 0xFFFF indicating infinite wait Bootup NumLock State Sets keyboard NumLock status Quiet Boot Enables disables Quiet Boot option Fast Boot Enables disables boot with the minimal de...

Страница 74: ...pecifies the priority of boot devices with all installed boot devices detected during POST and displayed where selecting Boot Option specifies the desired boot device A 5 Save Exit Save Changes and Ex...

Страница 75: ...p options Discard Changes Discards changes to any of the setup options Restore Defaults Restores loads default values for all setup options Save as User Defaults Saves changes as User Defaults Restore...

Страница 76: ...64 BIOS Setup Leading EDGE COMPUTING This page intentionally left blank...

Страница 77: ...and 50 C with adapter supply When installing mounting or uninstalling removing device or when removal of a chassis cover is required for user ser vicing See Getting Started on page 23 Turn off power...

Страница 78: ...n the thumbscrews with a screwdriver before starting the system up It is recommended that the device be installed only in a server room or computer room where access is Restricted to qualified service...

Страница 79: ...g this surface could result in bodily injury To reduce risk allow the surface to cool before touching RISQUE DE BR LURES Ne touchez pas cette surface cela pourrait entra ner des blessures Pour viter t...

Страница 80: ...68 Important Safety Instructions Leading EDGE COMPUTING This page intentionally left blank...

Страница 81: ...0 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel...

Отзывы: