background image

Cooling System

 47

Figure 4-9: 

Clean or replace filter

3. Clean the existing filter or replace it with the one pro-

vided.

4. Place the filter back in position, replace the filter cover

and screws, and reinstall the filter module into the chas-
sis.

4.5 Temperature Alarm

When the subsystem’s internal temperature exceeds 50°C, the
TEMP LED will flash and an audible warning will be heard (see
Figure 5.2 above for LED location). To reset the alarm and disable
the audible warning, press the Alarm Reset button.

In order to protect the system from damage resulting from over-
heating, it should be shut down immediately. Inspect the operating
environment for causes of the overheating condition. After the sys-
tem has cooled down sufficiently, power it up and be observant of
any future temperature alarm conditions.

Содержание cPCIS-6418U Series

Страница 1: ...Advance Technologies Automate the World Manual Rev 2 01 Revision Date December 21 2006 Part No 50 15040 1000 cPCIS 6418U Series 4U Height 8 Slot 6U CompactPCI Subsystem User s Manual...

Страница 2: ...tial damages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copy...

Страница 3: ...ice adlinktech com TEL 886 2 82265877 FAX 886 2 82265717 Address 9F No 166 Jian Yi Road Chungho City Taipei 235 Taiwan Please email or FAX this completed service form for prompt and satisfactory servi...

Страница 4: ......

Страница 5: ...7 2 3 Rear Transition Module Installation Removal 9 2 4 Power Supply Unit Replacement 10 2 5 Powering Up the System 12 3 Backplanes 13 3 1 Features 13 3 2 Specifications 14 3 3 Mechanical Drawing 15 P...

Страница 6: ...ii Table of Contents 5 Power Supply Unit 51 5 1 cPS H325 AC 51 Features 51 Specifications 51 Input Characteristics 52 Output Characteristics 52 Important Safety Instructions 55 Warranty Policy 57...

Страница 7: ...cBP 6814U Backplane Rear View 16 Figure 3 3 cBP 6814U Backplane Front View 17 Figure 3 4 cBP 6814U Backplane Rear View 18 Figure 3 5 cBP 6814U N110 Backplane Rear View 19 Figure 4 1 System Alarm Board...

Страница 8: ...iv...

Страница 9: ...tors chassis temperature voltage and fan status and provides an RS 232 interface on the rear panel 1 1 Features General X 4U height for 6U cPCI cards with 80mm rear RTMs for I O X Bench top or standar...

Страница 10: ...rear panel Boards Space X Board space supports standard 6U height and 8 slot width X One 4HP system slot at bottom dual slot system boards occupy one peripheral slot X Both front and rear access poss...

Страница 11: ...module on R side 4 offset fans One exhaust fan on L side One exhaust fan at rear for PSU and drive bay cooling All fans support hot swap Drive Bay Space for one slim type EIDE CD ROM Power Supply Supp...

Страница 12: ...4 Introduction 1 3 PCIS 6418U Mechanical Layout Figure 1 1 cPCIS 6418U Front View Figure 1 2 cPCIS 6418U Rear View...

Страница 13: ...Introduction 5 Dimensions in mm Figure 1 3 cPCIS 6418U Top View Figure 1 4 cPCIS 6418U Side View...

Страница 14: ...drive support be sure that the appropriate CPU module and Rear Transition Module are ordered 1 5 Customized Systems Subsystems can be customized to meet the specific needs of your application To cust...

Страница 15: ...ackage includes power cords for 110V and 220V wall sockets replacement air filter ergonomic rack mount handles and pouch containing screws zip ties etc X This User s Manual 2 2 CompactPCI Card Install...

Страница 16: ...use without blanking plates for all empty slots otherwise the EMC and cooling performance will be compromised 2 Hold the SBC module or peripheral card horizontally Make sure that the handles are unla...

Страница 17: ...odule handles securely 6 To remove the module undo the retaining screws press the red release buttons and reverse steps 1 through 5 above 2 3 Rear Transition Module Installation Removal The installati...

Страница 18: ...stallation procedures for PSUs are the same as for CompactPCI cards except there is only one han dle To replace a PSU module refer to the figures and instructions below 1 To remove the PSU module undo...

Страница 19: ...ting Started 11 2 Pull outwards to remove the PSU Figure 2 4 Pull outwards to remove the PSU 3 Insert the new PSU module push on the handle until it latches into position and replace the retaining scr...

Страница 20: ...to the appropriate card slots as described in Sections 2 2 and 2 3 The cPCIS 6418U Subsystem features a guarded power switch Use the tool provided in the Accessory Packet or a suitably shaped object s...

Страница 21: ...the backplane for the cPCIS 6418U Subsystem and has the same features as the cBP 6418U but does not support CT Bus 3 1 Features X Standard CompactPCI 3U height for 6U cPCI cards X Supports 80mm rear I...

Страница 22: ...bit 33MHz X System slot rear I O P3 P4 and P5 rear I O with AB type shroud X Peripheral slots four X H 110 bus Compliant with PICMG 2 5 for all peripheral slots cBP 6418U N110 does not support CT Bus...

Страница 23: ...Backplanes 15 3 3 Mechanical Drawing Power Section Figure 3 1 cBP 6814U Backplane Front View...

Страница 24: ...16 Backplanes Figure 3 2 cBP 6814U Backplane Rear View Note cBP 6814U N110 does not have connectors CN3 and CN17...

Страница 25: ...Backplanes 17 CompactPCI Section Figure 3 3 cBP 6814U Backplane Front View Red triangle indicates system slots Slot 8 Blue circles are peripheral slots Slots 1 7...

Страница 26: ...18 Backplanes Figure 3 4 cBP 6814U Backplane Rear View...

Страница 27: ...Backplanes 19 Figure 3 5 cBP 6814U N110 Backplane Rear View...

Страница 28: ...DC IN 31 GA2 46 ACN DC IN 30 V1 SENSE 45 CGND 29 V1ADJ 44 V3 SHARE 28 GA1 43 IPMB_PWR 27 EN 42 FAL 26 RESERVED 41 V2 SHARE 25 GA0 40 IPMB_SDA 24 RTN 39 INH 23 RESERVED 38 DEG 22 RTN 37 IPMB_SCL 21 V4...

Страница 29: ...Backplanes 21 System IPMB Connector CN2 Album Power CN3 Pin Signal 1 IPMI_CLK 2 GND 3 IPMI_DATA IPMI_Power ALERT Pin Signal 1 12V 2 5V 3 3 3V 4 GND 5 12V 1...

Страница 30: ...ta 9 Host data 5 7 8 Host data 10 Host data 4 9 10 Host data 11 Host data 3 11 12 Host data 12 Host data 2 13 14 Host data 13 Host data 1 15 16 Host data 14 Host data 0 17 18 Host data 15 Ground 19 20...

Страница 31: ...ector CN9 12V Connector CN10 Pin Signal Pin Signal 1 3 3V 11 3 3V 2 3 3V 12 12V 3 GND 13 GND 4 5V 14 PS_ON_L 5 GND 15 GND 6 5V 16 GND 7 GND 17 GND 8 PWRGOOD 18 5V 9 STB5V 19 5V 10 12V 20 5V Pin Signal...

Страница 32: ...24 Backplanes 5V Connector CN11 3 3V Connector CN12 Pin Signal 1 5V 2 GND Pin Signal 1 3 3V 2 GND...

Страница 33: ...ckplanes 25 Power IPMB Connector CN13 Power Sense CN14 INH Connector CN15 Pin Signal 1 IPMI_CLK 2 GND 3 IPMI_DATA IPMI_Power ALERT Pin Signal 1 12V 2 5V 3 3 3V 4 GND 5 12V Pin Signal 1 INH 2 GND 3 DEG...

Страница 34: ...26 Backplanes RST Connector J1 FAL Connector J2 INH Connector J3 Pin Signal 1 PRSTA 2 GND Pin Signal 1 FAL 2 GND Pin Signal 1 INH 2 GND...

Страница 35: ...17 GND 3 3V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BDSEL TRDY GND 12 14 Keying Area 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V...

Страница 36: ...rved GND Reserved GND 13 GND Reserved GND V I O Reserved Reserved GND 12 GND Reserved Reserved Reserved GND Reserved GND 11 GND Reserved GND V I O Reserved Reserved GND 10 GND Reserved Reserved Reserv...

Страница 37: ...erved Reserved Reserved Reserved Reserved GND 11 GND Reserved Reserved Reserved Reserved Reserved GND 10 GND Reserved Reserved Reserved Reserved Reserved GND 9 GND Reserved Reserved Reserved Reserved...

Страница 38: ...rved GND 16 GND Reserved Reserved Reserved Reserved Reserved GND 15 GND Reserved Reserved Reserved Reserved Reserved GND 12 14 Keying Area 11 GND Reserved Reserved Reserved Reserved Reserved GND 10 GN...

Страница 39: ...rved Reserved GND 13 GND Reserved Reserved Reserved Reserved Reserved GND 12 GND Reserved Reserved Reserved Reserved Reserved GND 11 GND Reserved Reserved Reserved Reserved Reserved GND 10 GND Reserve...

Страница 40: ...AR C BE 1 GND 17 GND 3 3V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BDSEL TRDY GND 12 14 Keying Area 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD...

Страница 41: ...d GND Reserved Reserved Reserved GND 14 GND AD 35 AD 34 AD 33 GND AD 32 GND 13 GND AD 38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 GND 11 GND AD 45 GND V I O AD 44 AD 43 GND 10 GND...

Страница 42: ...GND 12 GND Reserved Reserved Reserved Reserved Reserved GND 11 GND Reserved Reserved Reserved Reserved Reserved GND 10 GND Reserved Reserved Reserved Reserved Reserved GND 9 GND Reserved Reserved Rese...

Страница 43: ...ND 17 GND No Pin No Pin No Pin No Pin No Pin GND 16 GND No Pin No Pin No Pin No Pin No Pin GND 15 GND Vbat No Pin No Pin No Pin Vbat Rtn GND 12 14 Keying Area 11 GND CT_D29 CT_D30 CT_D31 V I O CT_FRAM...

Страница 44: ...Reserved Reserved Reserved GND 13 GND Reserved Reserved Reserved Reserved Reserved GND 12 GND Reserved Reserved Reserved Reserved Reserved GND 11 GND Reserved Reserved Reserved Reserved Reserved GND...

Страница 45: ...f Enumeration Bus Signals JP1 cBP 6814U only default 1 2 shorted V I O Setting Jumper J4 J6 default J4 J5 shorted Column 1 Column 2 Column 3 NC SGA0 GND NC SGA1 GND NC SGA2 GND NC SGA3 GND NC SGA4 GND...

Страница 46: ...38 Backplanes...

Страница 47: ...itional exhaust An embedded alarm board monitors fan status and initiates a visible and audible alarm upon fan failure and over temperature condition 4 1 System Alarm Board X Supports fault alarm for...

Страница 48: ...40 Cooling System Mechanical Drawing Figure 4 1 System Alarm Board Mechanical Drawing...

Страница 49: ...ure fan status Should a fan become disabled the Fan LED will light up and an audible warning will be heard To disable the audible warning press the Alarm Reset button The Fan LED will continue to flas...

Страница 50: ...ules please contact your ADLINK distributor Front Access Intake Fan 1 Loosen the screws attaching the front access intake fan module at the right side of the chassis 2 Pull the faulty fan module out o...

Страница 51: ...Cooling System 43 Rear Exhaust Fan 1 Loosen the screws attaching the rear exhaust fan mod ule PSU at the right rear of the chassis as shown below Figure 4 4 Remove the rear exhaust fan module PSU...

Страница 52: ...isconnect the rear exhaust fan module PSU power cable 3 Reverse steps 1 2 to replace the fan module Ensure the power cable is properly placed in the cut out on the fan casing to prevent it from catchi...

Страница 53: ...odule screws 2 Pull the fan module out of the chassis by the front edge disconnect the power cable and replace with a func tional fan module Figure 4 7 Remove the left exhaust fan module and disconnec...

Страница 54: ...ment air filter is supplied and can be found in the Accessory Packet Air Filter Removal and Replacement Procedure 1 Remove the front access intake fan module as shown in Figure 4 3 above 2 Lay the fan...

Страница 55: ...rature exceeds 50 C the TEMP LED will flash and an audible warning will be heard see Figure 5 2 above for LED location To reset the alarm and disable the audible warning press the Alarm Reset button I...

Страница 56: ...the alarm board connect a PC to the serial port on the rear of the cPCIS 6418U chassis using a 1 to 1 DB 9 cable not a nul modem cable Use Windows HyperTerminal to interface with the alarm board using...

Страница 57: ...Delta FFB0912EHE rear exhaust fan Z Dimensions 92 x 92 x 38mm Z Weight 198 g Z Type 12V DC brush less with ball bearing motor Z Rated voltage 12V 1 0A Z Rated power 12W Z Fan speed 4800 RPM Z Maximum...

Страница 58: ...50 Cooling System...

Страница 59: ...meets EN 55022 FCC CLASS A X CE marking compliance Specifications X Operating Temperature Range 0 C to 50 C at full load with specified air flow Derates linearly to 50 at 70 C X Storage Temperature 4...

Страница 60: ...ss A X Hold up Time 5mS after power fail signal X Remote ON OFF Available at INH EN pins X Power Fail Signal Available at FAL pin X Status LED Green means valid input voltage Amber means a critical fa...

Страница 61: ...lled at each rail X Output Wattage Typ 250W continuous X Output Connector Positronic 47 pin PCIH47M400A1 X Line Regulation Typ 0 1 X Load Regulation Typ 1 2 X Noise Ripple Typ 1 peak to peak or 50mV w...

Страница 62: ...54 Power Supply Unit...

Страница 63: ...voltage selector switch make sure that the switch is set to the proper position for the area The voltage selector switch is set at the factory to the cor rect voltage X For pluggable equipment ensure...

Страница 64: ...attery CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose used batteries as instructed in the instructions X The equipment should be checked by service personnel if one of t...

Страница 65: ...party products not manufactured by ADLINK will be covered by the original manufactur ers warranty X For products containing storage devices hard drives flash cards etc please back up your data before...

Страница 66: ...f battery fluid during or after change of batteries by customer user X Damage from improper repair by unauthorized ADLINK technicians X Products with altered and or damaged serial numbers are not enti...

Отзывы: