120
IPMI User Guide
9.5
Communications with IPMC
Operating systems need to use a serial port to communicate with
the IPMC. The resource setting of the serial port must be IO:
0x2F0 and IRQ: 7. The communication setting of the serial port
must be BaudRate: 9600, DataBit: 8, ParityCheck: None, StopBit:
1, and FlowControl: None. In Windows XP, use "COM6" to com-
municate with the IPMC.
9.6
IPMI Sensors List
Sensor
Number
Sensor name
Normal
Reading
Sensor Reading Value of
IPMI Get Sensor Reading
Command
01h
BMC Watchdog
Timeout action:
000b = no action
001b = Hard Reset
000b = Power Down
011b = Power Cycle
100b - 111b = reserved
02h
3.3V
3.3 V
Raw data of 3.3V sensor
03h
5V
5 V
Raw data of 5.0V sensor
04h
12V
12 V
Raw data of 12.0V sensor
05h
CPU Temp
40ºC
Raw data of CPU Temp sensor
06h
SYSTEM Temp
25ºC
Raw data of SYSTEM Temp
sensor
Содержание cPCI-6210 Series
Страница 6: ...vi Preface This page intentionally left blank ...
Страница 10: ...x Table of Contents This page intentionally left blank ...
Страница 12: ...xii List of Tables This page intentionally left blank ...
Страница 14: ...xiv List of Figures This page intentionally left blank ...
Страница 30: ...16 Specifications This page intentionally left blank ...
Страница 76: ...62 Getting Started This page intentionally left blank ...
Страница 80: ...66 Driver Installation This page intentionally left blank ...
Страница 94: ...80 Utilities 4 After the update process is complete system will auto matically reboot ...
Страница 110: ...96 BIOS Setup Utility 8 3 9 H W Monitor ...
Страница 124: ...110 BIOS Setup Utility This page intentionally left blank ...
Страница 136: ...122 IPMI User Guide This page intentionally left blank ...