116
IPMI User Guide
OemRescanGaInput
This command is used to rescan the geo-address input pins and
reset the IPMB address according to the input value.
OemTestFunction
Internal test purposes only.
OemSetBlueLEDLongBlinking
This command is used to enable or disable the slow blink of the
blue HotSwap LED when a voltage is detected to be over
±
5% out
of range for five seconds (see Table 4-1 on page 22).
This function
is set to enabled by default.
Action
Byte
Value
Description
Request
0
C0h
NetFn/LUN for OEM
1
22h
OEM defined command
Response
0
Complete Code
00h means OK
1
New IPMB address
New IPMB address value
Action
Byte
Value
Description
Request
0
C0h
NetFn/LUN for OEM
1
31h
OEM defined command
2
00h or 01h
00h: disable slow blink capability
01h: enable slow blink capability
Response
0
Complete Code
00h means OK
Содержание cPCI-6210 Series
Страница 6: ...vi Preface This page intentionally left blank ...
Страница 10: ...x Table of Contents This page intentionally left blank ...
Страница 12: ...xii List of Tables This page intentionally left blank ...
Страница 14: ...xiv List of Figures This page intentionally left blank ...
Страница 30: ...16 Specifications This page intentionally left blank ...
Страница 76: ...62 Getting Started This page intentionally left blank ...
Страница 80: ...66 Driver Installation This page intentionally left blank ...
Страница 94: ...80 Utilities 4 After the update process is complete system will auto matically reboot ...
Страница 110: ...96 BIOS Setup Utility 8 3 9 H W Monitor ...
Страница 124: ...110 BIOS Setup Utility This page intentionally left blank ...
Страница 136: ...122 IPMI User Guide This page intentionally left blank ...