Board Specific SEMA Functions
5.1.1
Voltages
The BMC of the Express-HLE implements a voltage monitor and samples several onboard voltages. The voltages can be read by calling the
SEMA function “Get Voltages”. The function returns a 16-bit value divided into high-byte (MSB) and low-byte (LSB).
ADC Channel
Voltage Name
Voltage Formula [V]
0 ---
---
1
+V3.3S
(MSB<<8 + LSB) x 1.100 x 3.3 / 1024
2
+V1.05S
(MSB<<8 + LSB) x 3.3 / 1024
3
+V3.3A
(MSB<<8 + LSB) x 1.100 x 3.3 / 1024
4
+VDDQ (V1.35 ~ V1.5)
(MSB<<8 + LSB) x 3.3 / 1024
5
+V5A_DUAL
(MSB<<8 + LSB) x 1.833 x 3.3 / 1024
6
+VIN
(MSB<<8 + LSB) x 6.000 x 3.3 / 1024
7
(MAIN CURRENT)
Use Main Current Function
5.1.2
Main Current
The BMC of the Express-HLE implements a current monitor. The current can be read by calling the SEMA function “Get Main Current”. The
function returns four 16-bit values divided in high-byte (MSB) and low-byte (LSB). These 4 values represent the last 4 currents drawn by the
board. The values are sampled every 250ms. The order of the 4 values is NOT in chronological order. Access by the BMC may increase the
drawn current of the whole system. In this case, there are still 3 samples not influenced by the read access.
Main Current = (MSB_n<<8 + LSB_n) x 8.06mA
5.1.3
BMC Status
This register shows the status of BMC controlled signals on the Express-HL.
Status Bit
Signal
0 WDT_OUT
1 LVDS_VDDEN
2 LVDS_BKLTEN
3 BIOS_MODE
4 POSTWDT_DISn
5 SEL_BIOS
6 BIOS_DIS0n
7 BIOS_DIS1n
Содержание COM Express Express-HLE
Страница 1: ...Express HLE User s Manual Manual Revision 1 01 Revision Date October 22 2014 Part Number 50 1J050 1010...
Страница 11: ...Express HLE Page 11 2 16 Mechanical Drawing...
Страница 21: ...Express HLE Page 21 3 3 10 USB Root Segmentation...
Страница 37: ...Express HLE Page 37 4 6 Express HLE Switch Settings 4 6 1 Switch Locations SW4 SW1 SW3...