62
BIOS Setup
Feature
Options
Description
COM4 Info
only
Console Redirection
Enabled
Disabled
Console Redirection Enable or Disable.
Console Redirection Settings
Submenu
The settings specify how the host computer and the
remote computer (which the user is using) will
exchange data.
Both computers should have the same or compatible
settings.
The item will be lunched before enable Console
Redirection.
Legacy Console Redirection
Info only
Legacy Console Redirection
Settings
Submenu
Legacy Console Redirection Settings
7.3.9.1.
Advanced > Serial Console Redirection > Console Redirection Settings (if COM1 enabled)
Feature
Options
Description
COM1 Info
only
Console Redirection Settings
Info only
Teriminal Type
VT100
VT100+
VT-UTF8
ANSI
Emulation:
ANSI: Extended ASCII char set.
VT100: ASCII char set.
VT100+: Extends VT100 to support color, function
keys, etc.
VT-UTF8: Uses UTF8 encoding to map Unicode chars
onto 1 or more bytes.
Bits per second
9600
19200
38400
57600
115200
Selects serial port transmission speed. The speed
must be matched on the other side. Long or noisy
lines may require lower speeds.
Data Bits
7
8
Data Bits
Parity
None
Even
Odd
Mark
Space
A parity bit can be sent with the data bits to detect
some transmission errors.
Even: parity bit is 0 if the num of 1's in the data bits is
even.
Odd: parity bit is 0 if num of 1's in the data bits is odd.
Mark: parity bit is always 1.
Space: Parity bit is always 0. Mark and Space Parity
do not allow for error detection.They can be used as
an additional data bit.
Stop Bits
1
2
Stop bits indicate the end of a serial data packet. (A
start bit indicates the beginning). The standard setting
is 1 stop bit. Communication with slow devices may
require more than 1 stop bit.
Flow Control
None
Hardware RTS/CTS
Flow control can prevent data loss from buffer
overflow. When sending data, if the receiving buffers
are full, a 'stop' signal can be sent to stop the data
flow. Once the buffers are empty, a 'start' signal can
be sent to re-start the flow. Hardware flow control uses
two wires to send start/stop signals.
VT-UTF8 Combo Key Support
Enabled
Disabled
Enable VT-UTF8 Combination Key Support for
ANSI/VT100 terminals
Содержание cExpress-AL
Страница 8: ...2 Introduction This page intentionally left blank ...
Страница 36: ...30 Pinouts and Signal Descriptions This page intentionally left blank ...
Страница 44: ...38 Module Interfaces This page intentionally left blank ...
Страница 48: ...42 Smart Embedded Management Agent SEMA This page intentionally left blank ...
Страница 88: ...82 BIOS Setup This page intentionally left blank ...
Страница 98: ...92 BIOS Checkpoints Beep Codes This page intentionally left blank ...